Summary of 850702 Meeting W/Doe in Silver Spring,Md Re Umtrap Radon Barrier Srp/Design Manual
ML20126L944
Person / Time
Issue date: 07/09/1985
From: Smykowski S
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Gillen D
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-WM-39 NUDOCS 8508010160
Download: ML20126L944 (2)


Text

. - -

Distribution:

ul file:

100 309 g E1EG r/f flFISS r/f JTGreeves 1

flSilataraja SSqykowski BJagannath G0nugnoli,IEILU RBrich, URF0 i

NOTE T0:

Daniel M. Gillen WDavis i

Low-Level Waste and Uranium NA Recovery Projects Branch O.Lorra Division of Waste Management FROM:

Steve Smykowski Engineering Branch l

Division of Waste Management

SUBJECT:

MINUTES FROM THE NRC/ DOE UMTRA RAD 0N BARRIER SRP/ DESIGN MANUAL MEETING - JULY 2, 1985 1

PARTICIPANTS: SteveSmykowski,WMEG(Lead)

MLU WM Record file W1 Pr@c: Jf__

Da EG Kenneth Baker, TAC /D0E Dxkt h.. __

James Keithley, RAC/D0E Pol e-LNR _.

~

l LOCATION:

Willste Building Distributign:

i e

pring, MD

~

l iRgturn tog 62J.s?) l~{ ]- } ~ ' - ' l{

l The following items were determined as a result of the meeting:

l 1.

The TAC will develop a rationale for the sampling plan that will be used when estimating radiological parameter values of the contaminated tailings j

material and radon barrier material. The rationale as applied to tailings material will take into consideration specific sampling plans based upon l

the type of remedial action that will be performed (i.e. homogeneous l

mixing of the tailings material during relocation versus stabilization of the tailings material in place). The NRC will prepare a parameter review procedure which would correspond to the DOE sampling plan.

2.

The DOE Design Manual will be based on the EPA criterion that limits the average radon release rate over the entire surface of the disposal site to 20 pCi/m s.

Designs considering the alternative standard that limit the j

annual average concentration of radon in air at or above any location i

outside the disposal site to 0.5 pC1/1 will not be included in the Design i

Manual. However, both alternatives of the EPA radon criterion will be addressed in the SRP.

[

i

)

)

  1. 82* 48t2 '"7o' WM-39 PDR l

I f

I f

JUL 0 9 1985 2

3.

The TAC will investigate the error analysis approach for estimating the cover thickness based upon testing error when detennining material parameter values for tailings and cover.

4.

The TAC will investigate testing procedures to be used by the DOE to verify that offsite locations comply with the EPA soil cleanup standards.

5.

A follow-up meeting is scheduled during the week of August 5 in Albuquerque, New Mexico. Randy Brich, URF0, will be an additional participant at this meeting.

6.

The NRC staff gave the TAC /RAC personnel draft copies of the Regulatory Guide on radon attenuation through tailings cover material. The TAC gave the NRC staff publications on sensitivity of parameters affecting the radon barier cover thickness, long-term moisture content determination, and the estimation of radiological parameter values, vox C' fq'^

Steve Smykowski Engineering Branch Division of Waste Management

- - -