ML20126L800

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 6387,Rev 10,for Model 60.Approval Record Encl
ML20126L800
Person / Time
Site: 07106387
Issue date: 07/22/1985
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20126L797 List:
References
NUDOCS 8508010037
Download: ML20126L800 (6)


Text

r

_ mum-mmmm mmmmmm m mm m m m m m mm m awJnananansnarmhwJnnnwwwmmwirnwnwnne NRC FOR3 618 U.S. NUCLEA'l REGULATORY CoMMISStoN -

+am CERTIFICATE OF COMPLIANCE

,I'g io Cm "

FCR RADIOACTIVE MATERIALS PACKAGES I a CERTIFICATE NUMBER o REVISaON NUMBER c PACKAGE 6DENTIFICATION NLMBER a PAGE NUMRER e TOTAL NUMBER P AGES j 6387 10 USA /6387/B( )F 1

5 1 2 PstEAMBLE i

a Tn,s certificate is issued to certify enat ene pac *ag,ng and contents desenbed in item s beiow. meets ine appile.oie safety standares set tortn in T. tie io. Code of Feceral Regulatg>ns. Part 71, ' Packaging of Radioactive Matenals for Transport and Transportation of Radioactive Matenas Under Certain Conditions "

ha b Tnis certificate does not reneve the consignor from compliance with any requirement of tne regulations of tne U S Department of Transportation or otner apphCable regulatory agencies, encluding tne government of any Country tnrougn or anto wntcn tne package will be transported E<1 9

1

.g i 3 THIS CERTIFICATE IS LSSUED ON THE BASIS OF A SAFETY atiALYSIS REPORT OF THE PACKAGE CESIGN OR APPUCATICN a PREPARED BY tName and Aodressr b TITLE AND IDENTtFICATION OF REPORT OA APPLICATION

.E U.S. Departmert of Energy Battelle Pacific Northwest Laboratories

E DP-122.2 application dated June 2,1980.

E 1

l j Washington, DC 20545 71-6387

)

k c DOCKET NUM8ER E

4 CONOsTIONS This certificate is conditional upon fulfeli ng tne requirements of 10 CFR Part 7 f. as apphcable, and the cond6tions specified below s.

1 (a)

Packaging I!

(1) Model No.:

Model 60 E

,E (2) Description

[

A metal " birdcage" enclosing a steel containment vessel for non-E irradiated fuel pins.

The stainless steel containment vessel is a 6-R 3

l inch diameter,101-1/4-inch long, Schedule 40 pipe.

One end is closed E

j with a 1-inch thick cover plate, bolted with eight, 3/4-inch diameter

j bolts to a welded,150-pound, neck type flange.

The gasket is a g

Flexitallic type, spiral wound, stainless steel, asbestos filter.

The lg cover plate is fitted with a rupture disk assembly designed for up to F

l 300 psi.

4 E

j-The containment vessel is centered inside a metal " birdcage" (18" x f

i 18" x 112.5", prismatic, cage frame made of 1-1/2" x l-1/2" x 1/4" ig angle iron), supported by six, 0.188-inch steel welded perpendicular g

l to its longitudinal axis and equally spaced along its body and by four B;

Schedule 80 stainless steel pipe spokes at each end.

The outer lP:

spacer cage is covered with expanded steel mesh. The loaded container

(

weight is approximately 1,000 pounds.

rg I:

B

,E:

l

'li:

I

!B-l i

(W

@l il l

lE I

5 l

ll i.

8500010037 850722 lp l

PDR ADOCK 07106387 jl, C

PDR g

!B in 4

f


mm,mmmmmmmmm_ mamm,,smmmmmmmyan,

CoNDiTicNS (continusd) l l

Page 2 - C.ertificate flo. 6387 - Revision No.10 - Docket No. 71-6387 5.

(a)

Packaging (Continued)

(3)

Drawings The packaging is constructed in accordance with Hanford Engineering l

Development Laboratory Drawing Nos. H-3-32429 (Sheets 1 and 2, Rev.

12; Sheet 3, Rev. 8; Sheet 4, Rev. 4; Sheet 5, Rev.1; Sheets 6 and 7, Rev. 0); H-3-42514, Rev. 0; H-3-39691, Sheet 1, Rev. I and Sheet 2, y

Rev. 0; and H-3-44280, Rev. O.

p j

(b) Contents g'

j 7

l (1) Type and fonn of miterial' l

cgy I

(i) Nonfissile' radioactive material, in capsules which meet the requirements of special fonn radioactive material.

y. -

(ii)

Unirradiated fuel pins containing mixed Pu0 in depleted or as pressed sintered pel ets of the following n'atural' U0for Th02 specifica tion:

Pellet diameter, inch 1 O.19 to 0.21

~

f j

< Pin diameter, finch

}

0.22 to 0.24 I

mJiaximum' fuel' length'," inches ~

37 '

i o

Maximun Pu0 > w/0 7. 7, _f 31-l

? aximunr%235 enrichment",fw/o 0.72 M

i Minimuw Pu-240 enrichment, w/o 10 Maximum Pu-241 content 1/2 content of Pu-240 i

Cladding material" SS l

Minimum cladding thickness', inch 0.015 i

i (iii) Unirradiated fuel pins' ^containing mixed Pu0 in U0,, enriched to any degree)in the U-235 isotope; Th0 may b$ substituted for E

depleted or natural U0 ; plutonium o uranium carbides and nitrides i:

are allowed. - All of tbe above as-solid pellets of the following j'g s pecifications-1 Maximum pin diameter, inch 0.60

)b Maximum fuel length, inch 37 i

Minimum Pu-240 enrichment in Pu0, w/

10

)

2 j!g Maximum Pu-241 content 1/2 content of Pu-240 Cladding material SS Minimum cladding thickness, inch 0.010 lg 9

(iv)

Pu0 and U0 enriched in the U-235 isotope in fuel pins or capsules

)

whibh meet $he requirements of special form radioactive material.

j i

(v) U-233 in any solid physical or chemical form with any moderation f

in capsules which meet the requirements of special form radioactive lg ma terial.

lN N

lE I

li N

in

h ---- ----------- - --------=------ amm,-mmm-----m==-

_ l coNonTioNs (continuso) l Page 3 - Certificate No. 6387 - Revision No.10 - Docket No. 71-6387 l

(

(vi) Np-237 and Am-241 in any solid physical or chemical form with any moderation in capsules which meet the requirements of special fonn radioactive material.

i (vii)

Pu-241 (in isolated form), Am-242, Cm-243, Cm-244, Cm-245, Cf-249 l

and Cf-251 in any solid physical or chemical form with any moderation '

in capsules which meet the requirements of special fom radioactive ma terial.

(viii) Pu-241 (non-isolated form), Pu-238, Pu-239, Pu-240 and U-235 in i

any solid physical or chemical form; provided the Pu-241 content s

i of the plutonium dass not exceed.50% of the Pu-240 content in capsules which1 meet-the redufrements of special fom radioactive ma terial. 'y "

,s 4- #

4 (2) Maximum quaniity of material per package j

The maximum package heat load shall not exceed 12.3 watts /ft of fuel i

i length wi'th the l maximum package heat load.not to exceed 37.0 watts, and plutonium in~ excess of twenty (20) curies per package must be in the form of metal., metal alloy _or reactor: fuel elements; and:

. g.

s.

For (i) ;For the contents described'in 5(b)(1)(ii),120 fuel pins.

l tthe contents 4 described-in 5(b),(1)(iii) and constrained in appropriate :

l

' pin holders as shos,in drawings'specified in 5(a)(3), the maximum s

l fissile:de.r.sity'shall not exceed 2.0 kg/ft for Pu02 2

in UO ver l

a maximum. length ofj37;inchesiof the package.

i

+

2 j

(ii) For the contents des 6ribed in-5(b)(1)(iv):

Greater than Type A s

quantity of radioactive material and fissile material contents not to-exceed the generally licensed mass limits as specified in 10 CFR.f71.22.

l (iii) For the contents described in 5(b)(1)(v):

280 grams, i

)lR (iv) For the contents described in 5(b)(1)(vi):

15 kgs total.

(v)

For the contents described in 5(b)(1)(vii):

3 grams total.

lE

R l

(vi) For the contents described in 5(b)(1)(viii):

900 grams fissile.

l (c) Fissile Class II and III In (1) Minimum transport index to be shown on label for Class II.

!E It (i) For contents described in 5(b)(1)(ii) and limited in 5(b)(2)(i):

0.4 9

E E

I

,R lh

'N l

W W

l 5

1

,.....+ w, m, <

,m,. ;

. ~...,....

f l l m-mmm- = = - - - - Amm mmmmm mmmmmmm- - - --- amm mmmmmmmmm mm e am a m argg i

l \\

CENDITioNS tconhnued) p fI Page 4 - Certificate No. 6387 - Revision No.10 - Docket No. 71-6387

.E~gl

.5l

,4 i

'g 5.

(continued)

g, Iil!

'El (c)

Fissile Class (continued)

,E)

B i!

(ii) For contents described in 5(b)(1)(iii) and limited in 5(b)(2)(1):

7.0j i

(iii) For contents described in 5(b)(1)(v) and limited in 5(b)(2)(iii):

1.3lj ti (iv)

For contents described in 5(b)(1)(vi) and limited in 5(b)(2)(iv):

0.2i:

El (v)

For contents described.in 5(b)(1)(vii) and limited in 5(b)(2)(v):

0.6)

(vi) For contents <desdritYed kh E(b)(l')(viii) and limited in 5(b)(2)(vi):

c u.-

g) i Maximum grams fissile Transport E{

j per container Index c

<l50 0.1 g]s g

1.3' -

g l

W 500 w

(

900 7.0 Ei

~

bl l

(2) Maximym number of pa'ckages per shipment for Class III;

,bj Contebs describediih 5(b')(1)(iv) a'nd limited in 5(b)(2)(ii):

One g=

m l

6.

For mixtures of) isotopes'specified in 5(b)(1)(viii) and 5(b)(1)(v) and limited

,g:

in 5(b)(2)(vi), 5.(c)(1)(vi), 5(b)(2)(iii) and 5(c)(1)(iii) the sum of the ratios

t

of the content masses to their respective approved. mass limits shall not exceed Ei l

uni ty.

h For the contents specified in 5(b)(1)(iii) and 5(b)(1)(ii) and limited in 5 gi 7.

and 5(c)(1)(ii) nitrides and carbides may be shipped under the same limits as hj b

i oxides.

The fuel pins shall be positioned in a stainless steel pin holder

{l l

providing a close packed 5.7-inch diameter array, and:

(a) For pin holders containing bebeerr 58 and 120 pins in stainless steel tubes the minimum tube wall thickness shall be 0.035 inches; i!

(b)

For pin holders containing between 35 and 57 pins in stainless steel tubes, f

the minimum tube wall thickness shall be 0.050 inches.

8.

The packaging shall be equipped with a FIKE Assembly Number 1/2SP10A rupture

}

l unit having a muffled outlet, 304 SS body, and nickel rupture disc to burst at g

less than 300 psi.

R R

W

>N lN Iifff M

E

F

.g w --------


mmmmm..

mmmmems ms=.mmm...mA g CONDITIONS (continusd) i b

t

'g Page,5 - Certificate No. 6387 - Revision No.10 - Docket No. 71-6387 V

M l

9.

The package authcrized by this certificate is hereby approved for use under the general license provisions of 10 CFR 671.12.

py i

[

10.

Expiration date:

July 31, 1990.

y BI REFERENCE Battelle Pacific Northwest Laboratories' application dated June 2,1980, and ledgible

)

til copies of all drawings specified in Item 5(a)(3)..

?

c, b :

'~~w.

s 7 FOR THE U.S. NUCLEAR REGULATORY COMf11SSION

(~, v

?

h l

,g l

y, Charles E. MacDonald, Chief 6 Transportation Certification ' Branch

~

Division _of Fuel Cycle and

~

, }taterial' Safety,. NMSS

.g) e

'y l

Date:

N 22 W

~

$p

g L. ' ' '- 7. y l
g

..j 4 4 s

,4,) !

i e

D l

if lE l~

lR l

l>

a l

!,N lE

E lH
n i

lP.

[9

!E 5

lE i

R l
h A

lN iu lE N

in l

Il lh lN jn II l

!N l

!B i

'!n

)

(~

'*f**

UNITED STATES eq.

'gi%[,ij NUCLEAR REGULATORY COMMISSION 0 1-;,

/

wasamoron. o. c. 20sss

\\;5....,

'J4 Transportation Certification Branch Approval Record Model No. Model 60 Package Docket No. 71-6387 By application dated June 28, 1985, U.S. Department of Energy requested renewal of Certificate of Compliance No. 6387.

No changes have been requested or made to the package since issuance of the latest revision to the Certificate of Compliance dated February 9,1984.

The staff concludes that the statements of the original application dated June 2,1980, satisfy the requirement for renewal of the certificate of compliance.

==

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date>lUL 2 2 1985

..