ML20126L271

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to TR 017, TMI-1 Nuclear Generating Station Natural Circulation Cooldown Analysis W/O Reactor Vessel Upper Head Void Formation, Revising Util 840404 Response, Per Mods to Heating 6 Model.Procedure OP-1102-16 Modified
ML20126L271
Person / Time
Site: Crane 
Issue date: 07/24/1985
From: Hukill H
GENERAL PUBLIC UTILITIES CORP.
To: Stolz J
Office of Nuclear Reactor Regulation
Shared Package
ML20126L273 List:
References
5211-85-2130, GL-81-21, NUDOCS 8507310142
Download: ML20126L271 (1)


Text

.______________

GPU Nuclear Corporation 4 Nuclear

,ome
,y8o s

Middletown, Pennsylvania 17057-0191 717 944-7621 TELEX 84-2386 Writer's Direct Dial Number:

July 24, 1985 5211-85-2130 Office of Nuclear Reactor Regulation Attn:

J. F. Stolz, Chief Operating Reactor Branch No. 4 Washington, DC 20555

Dear Mr. Stolz:

Three Mile Island Nuclear Station Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Natural Circulation Cooldown (GL 81-21)

Revised Response Enclosed please find Revision 1 to TR #017 entitled "TMI-1 Nuclear Generating Station Natural Circulation Cooldown Analysis Without Reactor Vessel Upper Head Void Formation." This analysis revises our response of April 4,1984.

This revised analysis was performed as a result of modifications to the TMI-1 HEATING 6 model. The existing natural circulation cooldown procedure (0P-1102-16) has been modified pursuant to 10 CFR 50.59 to incorporate these results.

Sincerely, 1

D. H kill Director, TMI-1 HDH/CWS/spb cc:

R. Conte J. Thoma Enclosure 8507310142 850724 0322A PDR ADOCK 05000289 P

PDR l

l I I I

GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation

.