i
~
UNIVERSITY OF WISCONSIN f
l SQ Cy Nuclear Engineering Department
-l
%,30+
}
153 Engineering Research Building
-t 1500 Jonnson Ortwe
-f Madison. WI 53706
'W Phone 263-1646 Area Code (608) g 2
t a
Sep tember 11, 1984 f
- 1 t
To:
Committee Members
?
Steam Explosion Experts Group i
From: Michael Corradini Assis*; ant Committee Chairman Mr. C. Allen of NRR and T. Ginsberg, the Comittee Chairman, have requested that I compile a list of meetings and open publications where the Sandia ste?.m explosion work has been reviewed and/or analyzed by other investigators in regard to direct containment failure (i.e. ' alpha-mode' failure).
I have compiled an initial list of documents which are described in Enclosure 1.
This is by no means a complete list of steam explosion phenomena, rather it is meant to be a list of only those documents analyzing and/or utilizing Sandia steam explosion research work in regard to alpha-mode failure.
I request that all committee members review this compilation and the attached documents to check for completeness and to familiarize themselves with past investigations.
If certain pertinent documents have been inadvertently d
omitted from this compilation, it is the duty of the committee member to inform me or Mr. Allen or Ginsberg and to personally distribute the documents to the rest of the committee members.
In this way all members will be furnished with complete and up-to-date information.
8506190309 e40911 PDR REVQP NRCSERO PDR
.m
i.
.i i
Past Critical Reviews of the Sandia Steam Explosion Work t
I.
Meeting Reviews (see attached documents)
.]
A.
Zion / Indian Point Risk Studies Review Meeting, April 1982 I
B.
Technical Review Meeting on Steam Explosions, May 1982 C.
Molten-Core-Coolant Interaction Research Review Group, June 1984 7
II.
Bibliography of Important Past Reviews of Sandia Experiments and 3
alpha-mode failure III.
Key Papers on the Critical Review of Sandia Experiments and alpha-mode failure (see attached documents) 1 e-l l
l l
l 1
II.
Bibliography 1.
S.G. Bankoff, " Vapor Explosions:
A Critical Review," Proc. 6th Int'1.
Heat Transfer Conference, 6 p 355 (1978).
[
4 2.
S.G. Bankoff et al., " Steam Explosions - Their Relationships to LWR
's Safety Assessments," Int'1. Mtg. on Thermal Reactor Safety, Chicago, IL 2
(August 1982).
3.
S.G. Bankoff et al., "A Model for Fragmentation of Molten Metal Oxides in Contact with Water," Int'1. Mtg. on LWR Severe Accident Evaluation, e
Cambridge, MA (August 1983).
2 4.
M.J. Bird, " Thermal Interactions Between UO2 and Water:
Experimental
~
Study using Thermite-Generated U0," Fuel-Coolant Interactions, HTO-V19, 2
ASME Winter Annual Mtg., Wash. OC (Novemoer 1981).
5.
M.J. Bird, "An Experimental Study of Scaling in Core Melt / Water Interactions," ASME 22nd NHTC, No. 94-HT-7, Niagara Falls, NY (August
[
1984).
6.
C. Caracnalios et al., "A Transient Two-Phase Model to Describe Thermal Detonation Based on Hydrodynamic Fragmentation," Int'1. Mtg. on LWR T
Severe Accident Evaluation, Cambridge, MA (August 1983).
7.
D.H. Cho et al., "Some Aspects 3f Mixing in a Large-Mass Energetic FCI,"
Int'1 Mtg. on FRS, CONF-761001, V4, Chicago, IL.(October 1976).
8.
M.L. Corradini, D.E. Mitchell, L.S. Nelson, "Recent Experiments and Analysis Regarding Steam Explosions," Fuel-Coolant Interactions, _HTD-19, 49 (1981).
9.
M.L. Corradini, "Phenomenological Modelling of the Triggering Phase of Small Scale Steam Explosion Experiments," Nuclear Science and 7_8, 154 (1981).
8 Engineering, 10.
M.L. Corradini, 0.V. Swenson, R.L. Woodfin, L.E. Voelker, " Probability of Containment Failure Due to Steam Explosions Following a Postulated Core Meltdown Accident in a Light Water Reactor," Nuclear Engineering and Design, 66,, 287 (1981).
11.
M.L. Corradini, "A Proposed Model for Fuel-Coolant Mixing During a Core-Melt Accident," Int'1. ANS/ ENS Mtg. on Therm 11 Reactor Safety ( August 1982).
12.
M.L. Corradini, " Hydrogen Generation During Molten Fuel-Coolant Interactions," Int'1. Mtg. on Hydrogen Behavior (October 1982).
13.
M.L. Corradini, 0.V. Swenson, R.L. Woodfin, "An Analysis of Containment Failure by a Steam Explosion Following a Postulated Core Meltdown Accident in an LWR," Nuclear Safety, E(1), 21 (1982).
14 M.L. Corradini, " Analysis and Modelling of Large Scale Steam Explosion Experiments," Nuclear Science and Engineering, R (Decemcer 1982).
l
15.' M.L. Corradini, "Modelling Film Boiling Destabilization Oue to a Pressure Shock Arrival," Nuclear Science and Engineering, 84 (1983).
16.
M.L. Corradini, G.A. Moses, "A Dynamic Model for Fuel-Coolant Mixing,"
'j Int'1. Mtg. on Severe Accident Evaluation, Cambridge, MA (August 1983).
f 17.
M.L. Corradini, N.A. Evans. 0.E. Mitchell, " Hydrogen Generation During Y
Fuel-Coolant Interactions," Int'1. Mtg. on Severe Accident Evaluation,
.I Cambridge, MA (August 1983).
i 18.
M.L. Corrdini, " Fuel-Coolant Interactions with Molten Core Materials ana Water," Nuclear Science and Engineering 81 (1984).
19.
M.L. Corradini, " Limits to Fuel-Coolant Mixing," Nuclear Science and Engineering (submitted May 1984).
20.
H.K. Fauske, R.E. Henry, " Interpretation of Large Scale Vapor Explosion Experiments with Application to LWR Accidents," Int'1 Mtg. on LWR Severe Accident Evaluation, Camcridge, MA (August 1983).
21.
R.E. Henry, H.K. Fauske, " Core Melt Progression and the Attainment of a Permanently (Coolable State," Proc. Thermal Reactor Fuels Mtg., Sun Valley, 10 August 1981).
~
t 22.
R.E. Henry, H.K. Fauske, " Required Initial Conditions for Energetic Vapor Explosions," Fuel-Coolant Interactions HTD-V19, ASME Winter Annual Meeting, Wash. DC (Novem0er 1981).
23.
R.E. Henry et al., " Vapor Explosiin Potentials Under LWR Hypothetical Accident Conditions," ANS Thermal Reactor Safety Mtg., Sun Valley,10 (March 1981).
24 W. Schwalke et al., " Investigations on Shock Waves in Large Scale vapor Explosions," Fuel-Coolant Interactions, HTD-V19, ASME Winter Annual Meeting, Wash. DC (Novemoer 1981).
25.
D. Squarer and M. Leverett, " Steam Explosion in Perspective," Int'1. Mtg.
on LWR Severe Accident Evaluations, Cambridge, MA (August 1983).
26.
T.G. Theofanous, M. Saito, "An Assessment of Class-9 (Core-Melt)
Accidents for PWR Dry-Containment Systems," Nuclear Eng. 4 Design, 66, No. 3 (1982).
27.
P. Turinsky et al., " Boiling Film Growth in a Core-Melt-Water System,"
2nd Proceedings of Nuclear Thermal-Hydraulics, ANS Annual Mtg.) New Orleans, LA Wune 1984).
28.
H. Unger et al., "The Role of Steam Vapor Explosions during Core Meltdown of LWR's," Int'1. Mtg. on Thermal Reactor Saf ty, Chicago, IL ( August 1982).
J
Dr. C. Allen Dr. T. Ginsberg Nuclear Regulatory Commission Brookhaven National Labos c'.ory t
Washington, DC 20555 Building 820M l
Upton, NY 11973 g
3 Dr. S.G. Bankoff W.P. Murphy Professor of Chemical Dr. F. Mayinger
. -f*
and Mechanical Engineering Institute for Thermodynamics
-f Northwestern University University of Munich C
2145 Sheridan Road Federal Republic of Germany i
Evanston, IL 60201 Dr. D. Squarer Dr. M. Berman Nuclear Safety and Analysis Sandia National Laboratories Electric Power Research Inst.
+
Oivision 6441 3412 Hillview Avenue Albuquerque, NM 87185 Palo Alto, CA 94304 Dr. William Bohl Dr. T. Theofanous Los Alamos National Laboratory Purdue University PO Box 1663 West Lafayette, IN 47907 Los Alamos, NM 87545 Dr. Anthony Briggs Safety and Engineering Science Division UKAEA Atomic Energy Establishment Winfrith Dorchester
~
Dorset OT2-80H England Mr. T. Butler Nuclear Regulatory Comission Washington, DC 20555 Dr. I. Catton Department of Nuclear and Mechanical Engineering University of California 2567 Boelter Hall Los Angeles, CA 90024 Or. O. Cho Argonne National Laboratory RAS Division 9700 South Cass Avenue Argonne, IL 60439 Mr. P. Cybulskis Nuclear Systems Section Battelle Columbus Laboratory 505 King Avenue Columbus, OH 43201 L
.