ML20126K648

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900039/80-02 on 801027-31 & Notice of Deviation
ML20126K648
Person / Time
Issue date: 12/03/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Sluis J A
RHINE-SCHELDE-VEROLME ZWARE APPARATENBOUW
Shared Package
ML20126K626 List:
References
REF-QA-99900039 NUDOCS 8105200127
Download: ML20126K648 (2)


Text

^

N UNITED STATES

,/

o NUCLEAR REGULATORY COMMISSION j)

-/.8 REGION IV g

g 611 RYAN Pt.AZA oRIVE, SulTE $000 ARUNGToN. TEXAS 76011 O

osocciseo Docket No. 99900039/80-02 Rhine-Schelde-Verolme Zware Apparatenbouw b.v.

Attn: Mr. J. P. A. Sluis

' Managing Director Heijplaatstraat 4, P. O. Box 221 Rotterdam, THE NETHERLANDS Gentlemen:

This refers to the QA Program inspection conducted by Mr. L. E. Ellershaw of this office on October 27-31, 1980, of your facility at Rotterdam, THE NETHERLANDS, associated with the fabrication of nuclear vessels and to the discussions of our findings with Mr. M. Lodder and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented.

The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor' to assure that a specific product, component or service provided by you to your customers, is of acceptable quality.

As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.

You should therefore not conclude that the NRC's inspection exempts you from inspections'by an NRC licensee cr his agents nor frem taking effective cor-rective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements.

The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a

-written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the date your corrective actions and preventive measures were or will be ccmpleted.

8105200l$f

~ ~

+

s Rhine-Schelde-Verolme Zware Apparatenbouw b.v.

2 In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2. Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report centains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure.

Any such application must include a full statement of the reasons en the basis of which it is claimed that the informa-tion is1 proprietary, and should be prepared so that proprietar; information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, i

/

Uldis Potapovs, Chief I Vendor Inspection Branch Enclosures :

- 1.

Notice of Deviation 2.

Inspection Report No. 99900039/80-02 i

w,e-v,-

nn-

---,.--.w,-

,.mer,

-s,.,a

.,w,rr-,-,ivn.w-n r,

, m e,

o r-

-c-u

--+-,r-e,w -=-

r-we