December 29, 1992 tiOTE TO:

Don Lanham, IRH/0MB M/S P1 37 iROM:

John Thompson, SBWR Project Hanger, ADAR

SUBJECT:

Information to be sent to Docket 52-004 Please place in the POR and LPOR under Docket number 52-004 the attached sheet.

Please contact me at 504-1113 if you have any questions regarding this 4

matter.

I i

John Thompson l

l 1

b;

'?{'

s

', \\,

(10 ' )_ Q u.

i

?

9301070141 921229 ADOCK0520g4 PDR

h( W}{

bS*0

~~

~

pene Suggested Agenda Items for Meetings on Modular Construction Techniques Description of types of structural modules to-bi used, including:

- modules fabricated off-site with final assembly at an on-site shop.

- modules fabricated entirely on-site in a module assembly area.

Description of erection plans.

Description of QC/QA program for on-site storage.

t-Dif ferences in analysis and design criteria resulting f rom the use of modular construction.

Experience in the design, etc., of structural modules.

}.

Discussion of codes, standards, tests and practices to be used to address the following parameters:

Ductility, stif fness and stif fness degradation of modules and structures.

Strength and reliability of joints and connections of modules.

I-Damping values for seismic analysis of modules.

QA/QC for design, fabrication, shipping, erection, ISI,

& maintenance of modules.

Functional sensitivity of nodules to the above parameters.

l DBA structural safety margins

& ultimate structural i

capacities for use in PRAs.

Verification tests defined, if needed.

Access to Japanese testing results.

Discussion of ITAACs for construction of modular units.

Plans for accessibility for inservice inspection, maintenance, and repair.of modular units during operation.

-3:11pm Mon, 30 Nov 1992 C:\\ MOD \\ AGENDA

_=

a s

December 29, 1992 I40TE 10:

Don Lanham, IRH/DMB H/S P1 37 FROM:

John Thompson, SBWR Project Hanger, ADAR

SUBJECT:

Information to be sent to Docket 52-004 Please place in the PDR and LPDR under Docket number 52-004 the attached sheet.

Please contact me at 504-1113 if you have any questions regarding this-matter.

John Thompson

~

jftY o

(06 J ', $'

OU"L0u p

f{'

I 9301070141-921229 PDR ADOCK 05200004 A

PDR

'1bc m>(32-00Y (2 fif, Suggested Agenda items for Meetings on Modular Construction Techniques Description or types of structural modules tQ -be used, including:

- modules fabricated off-site with final assembly at an on-site shop.

- modules fabricated entirely on-site-in a module assembly area.

Description of erection plans.

Description of QC/0A program for on-site storage.

Dif f erences in analysis and design criteria resulting f rom the use of modular construction.

Experience in the design, etc., of structural modules.

Discussion of codes, standards, tests and practices to be used to address the following parameters:

Ductility, stif fness and stif fness degradation of modules and structures.

Strength and reliability of joints and connections of modules.

l l

Damping values for seismic analysiJ of modules.

OA/OC for design, fabrication, shipping, erection, ISI,

& maintenance of modules, Functional sensitivity of modules to the above parameters.

DBA structural safety margins & ultimate structural capacities for use in PRAs.

Verification tests defined, if needed.

Access to Japanese testing results.

Discussion of ITAACs for construction of' modular units.

Plans ~ for accessibility for inservice inspection, maintenance,

and repair of modular units during operation.