ML20126H479

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99901003/85-01 on 850325-29. Weaknesses Noted in Audits Conducted at Varco Heat Treating Co & Downey Heat Treating Co
ML20126H479
Person / Time
Issue date: 06/14/1985
From: Zech G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Stubbs A
WESTERN CONCRETE STRUCTURES, INC.
Shared Package
ML20126H483 List:
References
REF-QA-99901003 NUDOCS 8506180355
Download: ML20126H479 (2)


Text

F

[

Y A

UNITED STATES NUCLEAR REGULATORY COMMISSION j

WASHINGTON, D. C,20555

\\,,

June 14, 1985 Docket No. 99901003/85-01 g

M Western Concrete Structures, Inc.

ATTN: Mr. A. H. Stubbs President 19113 S. Hamilton Avenue Gardena, California 90248 Gentlemen:

This refers to the inspection conducted by Messrs. K. R. Naidu and T. F. Burns of this office on March 25-29, 1985, of your facility at Gardena, California, and that of your vendors, Varco Heat Treating Company and Downey Heat Treating Company, and to the discussions of our findings with you and members of your staff at the, conclusion of the inspection.

This inspection was made to verify that the post-tensioning components procured

" 'and supplied by you were manufactured under a Quality Assurance Program which meets the requirements of 10 CFR 50 Appendix B.

Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and represent-ative records, interviews with personnel, and observations by the inspectors.

In general, weaknesses were noted in the audits conducted by Western Concrete Structures, Inc. of your subcontractors.

In particular, audits of Varco Heat Treating Company and Downey Heat Treating Company failed to identify weaknesses in these companies' programs.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this.

letter and the enclosed inspection report will be placed in the,NRC's Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you, Sincerely, 7

' ~)

~

i Gary ech, Chief Vendor Program Branch Division of Quality Assurance, Vendor, and Technical Training Center Programs Office of Inspection and Enforcement

Enclosure:

Appendix A-Inspection Report 99901003/85-01 g7 y 0*iginal W mt M mh (g 8506180355 850614

g;o,gg99 escgs pwth a siri a a

P Western Concrete Structures, Inc.

June 14, 1985 l

DISTRIBUTION:

DMB:IE:09 VPB Reading DQAVT Reading RVollmer JTCollins JStone GHolahan, NRR/0RAB EMerschoff KRNaidu TBurns, BNL VitB:

AVT B:DQAVT B:DQAVT VT KRNaidu: sam erschoff GG ech mes 5/ ///85 5/1 /85 5/f85

//#85

.