ML20126G170
| ML20126G170 | |
| Person / Time | |
|---|---|
| Issue date: | 12/16/1992 |
| From: | Cintula T NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD) |
| To: | Rosenthal J NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD) |
| Shared Package | |
| ML20126G173 | List: |
| References | |
| AEOD-T92-10, NUDOCS 9301040097 | |
| Download: ML20126G170 (1) | |
Text
'
DEC 161992 MEMORANDUM FOR:
Jack E. Rosenthal, Chief Reactor Operations Analysis Ilranch Division of Safety Programs Office for Analysis and Evaluation of Operational Data -
FROM:
Theodore C. Cintula Reactor Systems Section CE and GE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data
SUBJECT:
PROSPECTIVE TREND OF LOW RELIABILITY EMERGENCY DIESEL GENERATORS Enclosed is a Technical Review Report on emergency diesel generators (EDGs) with less than a 95 percent yearly reliability to start and load run from 1988 through 1991. The raw data was provided by the Nuclear Management and Resources Council. We found that these low reliability EDGs subsequently improved to the industry average but were succeeded by a new group of low reliability EDGs yearly.
Or@alWO Theodore C. Cintula Reactor Systems Section CE and GE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data
Enclosure:
As stated cc w/ enclosure:
F. Rosa, NRR A. Serkiz, RES C. Johnson, RES H. Lewis, ACRS 3'00003 Distribution:
PDR_
JRosenthal LSpessard RSavio, ACRS -
- DQueener, N'OAC Central File?
VBenaraya KBrockman MTaylor, EDO VChexal, EPRI -
ROAB R/F Elordan SRubin KRaglin, TTC TCintula-Dross
'PBaranowsky AChaffee, NRR GLanik TNovak HKara ip nis Plewis, INPO ROABM RO
~Q I
[, K' g TCintula:rgz GI i-J osenthal 12/f/92 12//l/92 12//[ 92 1:awaa8'7 =g'-..... E l a m i' E n g g 4
$r93,'
u