ML20126G077

From kanterella
Jump to navigation Jump to search
Forwards Preliminary Safety Evaluation for Info Provided by GE Re Capacity of Reinforced Concrete Containment Vessel in App 19F of Ssar.Advises That Addl Info Necessary
ML20126G077
Person / Time
Site: 05200001
Issue date: 12/21/1992
From: Poslusny C
Office of Nuclear Reactor Regulation
To: Marriott P
GENERAL ELECTRIC CO.
Shared Package
ML20126G080 List:
References
NUDOCS 9301040056
Download: ML20126G077 (2)


Text

_ -

__ -_=___-

~-

r December 21, 1992 Docket No.52-001 Mr. Patrick W. Marriott, Manager Licensing & Consulting Services GE Nuclear Energy 175 Curtner Avenue San Jose, California 95125

Dear Mr. Marriott:

SUBJECT:

PREllMINARY INPUT TO FINAL SAFETY EVALUATION REPORT ON CONTAINMENT PERFORMANCE The Civil Engineering and Geosciences Branch has completed its review of the information provided by GE regarding the capacity of the Reinforced Concrete Containment Vessel in Appendix 19F of the Standard Safety Analysis Report (up to and including Amendment 21) and subsequent submittals in response to the staff's request for additional information.

Enclosed is a preliminary safety evaluation.

As a result of our review, we find that additional information is needed to complete our review related to the proposed ultimate ca)acity value, the internal pressure value, and the median fragility valve for tie reinforced concrete containment.

Please provide a plan in writing for resolving these concerns by January 15, 1993.

I expect that significant discussions on these concerns will be necessary, Sincerely, osi s"ny, roiect Manager Standardization Project Directorate Associate Directorate for Advanced Reactors and License Renewal Office of Nuclear Reactor Regulation

Enclosure:

Preliminary Safety Evaluation cc w/ enclosure:

See next page DISTRIBUTION:

Docket File PDST R/F DCrutchfield W7 ravers PDR WRussell, 12G18 RPierson JNWilson CPoslusny TBoyce PShea GGrant, 17G21 AThadani, 8E2 JMoore, 15B18 ACRS(10)

JKudrick, 801 AD'Angelo, 801 Slee, 10024 7)Tc/ta.o 7 Hi5

-^

"A

{}

PM:PDST@M SdPDfT:fDAR G Ba.gcM ~7HIS OFC:

LA:PDST:ADAR NAME: PSheaq[

CPoslusny:sg JNWil s'o$

DATE: 12/g/b2 12hM92 12rh/92

^

~ "

230037 0FFICIAL RECORD COPY:

DOCUMENT NAME:

SAFETYEV.CP c

9301040056 921221 PDR ADOCK 05200001 A

PDR g

GE Nuclear Energy Docket No.52-001

^

Mr. Robert Mitchell Mr. Joseph Quirk' j

General Electric Company GE Nuclear Energy 175 Curtner Avenue Mail Code 782 San Jose, California 95114 General Electric Compa.iy 175 Curtner Avenue Mr. L. Gifford, Program Manager San Jose, California 95114 Regulatory Programs GE Nuclear Energy 12300 Twinbrook Parkway Suite 315 Rockville, Maryland 20852 Director, Criteria-& Standards Division

_j Office of Radiation Programs U. S. Environmental Protection Agency 401 M Street..S.W.

Washington, D.C.

20460 Mr. Daniel F. Giessing U. S. Department of Energy NE-42 Washington, D.C.

20585 Mr. Steve-Goldberg Budget Examiner 725 17th Street, N.W.

Room 8002 Washington, D.C.

20503 Mr. Frank A. Ross U.S. Department of Energy, NE-42 Office of LWR Safety and Technology 19901 Germantown Road Germantown, Maryland 20874

+

j Mr. Raymond Ng j

1776 Eye Street, N.W.

Suite 300 i

Washington, D.C.

20006 t

Marcus A. Rowden, Esq.

Fried. Frank, Harris, Shriver & Jacobson-1001 Pennsylvania Avenue, N.W.

..Suito 800 Washington. D.C.

20004

. Jay.M. Gutierrez, Esq.

Newman & Holtzinger,'~P.C.-

1615_L Street, N.W.

4 Suite 1000 Washington, D.C.

20036-i

)

I

...