e.

4 7590-01 11HITED STATES NUCLEAR REGULATORY COMMISSION NORTHEAST NUCLEAR ENERGY COMPANY DOCKET NO. 50-336 NOTICE OF ISSUAhCE OF AMENDMENT TO FACILITY OPERATING llCENSE The U.S. Nuclear Regulatory Commission (Commission) has issued Amendment No. 167to facility Operating License No. OPR-65 issued to Northeast Nuclear Energy Company (the licensee), which revised the Technical Specifications for operation of the Millstone Nuclear Power Station, Unit No. 2 located in New London County, Connecticut. The amendment is effective as of the date of issuance.

The amendment incorporates into the Technical Specifications changes in the area of Tables 3.3-3, 3.3-4, 3.3-5 and 4.3-2, of Section 4.8.1.1.2 and of the Bases Section 3/4.3, to add the high containment pressure signal as an input to main steam isolation (MSI) and to reduce the feed isolation portion of MSI from 60 seconds to 14 seconds.

The application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations.

The Commission has made appropriate findings as required by the Act and the Commission's rules and. regulations in 10 CFR Chapter 1, which are set forth in the license amendment.

Notice of Consideration of Issuance of Amendment and Opportunity for Hearing in connection with this action was published in the-FEDERAL REGISTER on November 10, 1992 (57 FR 53518).

No request for a hearing or petition for leave to intervene was filed following this notice.

9212310196 92O23

.PDR ADOCK:OS000336

.P

\\pon

. The Commission has prepared an Environmental Assessment related to the action and has determined not to prepare an environmental impact statement.

Based upon the environmental assessment, the Commission has concluded that the issuance of this amendment will not have a significant effect on the quality of the human environment (57 FR 61101).

For further details with respect to the action see (1) the application for amendment dated October 28, 1992, as supplemented November 20, 1992 and December 4, 1992, (2) Amendment No.167 to License No. DPR-65, (3) the Commission's related Safety Evaluation, and (4) the Commission's Environmental Assessment.

All of these items are available for public inspection at the Commission's Public Document Room, the Gelman Building, 2120 L Street NW.,

Washington, DC 20555 and at the local public document room located at the Learning Resources Center, Thames Valley State Technical College, 574 New London Turnpike, Norwich, Connecticut 06360. A copy of items (2), (3) and (4) may be obtained upon request addressed to the U.S. Nuclear Regulatory Commission, Washington, DC 20555, Attention:

Document Control Desk.

Dated at Rockville, Maryland this 23rd day of December 1992.

FOR THE NUCLEAR REGULATORY COMMISSION k

David H. Jaffe, Act ng Senior Project Manager Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation L__..