ML20126F483

From kanterella
Jump to navigation Jump to search
Staff Requirements Memo Re Briefings on License Renewal Rulemaking Issues,Regulatory Guidance Issues & Industry Initiatives & Resources on 921207,08 & 18,respectively
ML20126F483
Person / Time
Issue date: 12/21/1992
From: Chilk S
NRC OFFICE OF THE SECRETARY (SECY)
To: Parler W, Taylor J
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO), NRC OFFICE OF THE GENERAL COUNSEL (OGC)
References
REF-10CFR9.7 M921207, M921208A, M921218C, NUDOCS 9212300340
Download: ML20126F483 (3)


Text

tecs

_/ >To ttQy% -

.v UNITED STATES -

NUCLEAR REGULATORY COMMISSION o

1 wassinoton. o.c,20sss o,

'f 1992 REFER TO:

M921207; IN RESPONSE, PLEASE

/

December 21, M921208A; AND orrect oF THE M921218C SECRETARY i

MEMORANDUM FOR:

James M. Taylor Executive Director for Operations William C.

Parler General Couns 4

h FROM:

amuel J. Chil,6 etary

SUBJECT:

STAFF REQUIREMENTS - BRIEFING ON LICENSE RENEWAL RULEMAKING ISSUES, 9:30 A.M.,

MONDAY, DECEMBER 7, 1992, COMMISSIONERS' CONFERENCE ROOM, ONE WHITE FLINT NORTH, ROCKVILLE, MARYLAND (OPEN TO PUBLIC ATTENDANCE) and BRIEFING ON LICENSE RENEWAL REGULATORY GUIDANCE ISSUES, 9:30 A.M.,

TUESDAY, DECrMBER 8,

1993, COMMISSIONERS' CONFERENCE ROOM, ONE WHITE FLINT NORTH, ROCKVILLE, MARYLAND (OPEN TO PUBLIC ATTENDANCE) and I

BRIEFING ON LICENSE RENEWAL INDUSTRY INITIATIVES ANL RESOURCES, 2200 P.M.,

FRIDAY, DECEMBER 18, 1992, COMMISSIONERS' CONFERENCE ROOM, ONE WHITE FL1NT NORTH, ROCKVILLE, MARYLAND (OPEN TO PUELIC ATTENDANCE)

The Commission 1 was briefed by the NRC staff on license renewal rulemaking, regulatory guide, and resource allocation issues in i

the above listed series _of meetings.

Additionally, the B&W Owners Group (B&WOG) briefed the Commission during.the December 18, 1992 meeting.

The B&WOG was represented by:

Pat Beard, Senior VP, Nuclear Operations, Florida Power Chairman, B&WOG Executive Committee Tony McConnell, Director, B&WOG Generic License Renewal Program Hal Tucker, Senior VP, Nuclear, Duke Power 230001 1

Commissioner de Planque was on official travel and did not attend the briefings on December 7 and 8, 1992.

1 0 9212300340 921221 O

PDR 10CFR v

'PT9.7 PDS s

~.

._, Jack _DeVine, VP & Dir, Nuclear Operations, GPU Nuclear Vice Chairman, D&WOG Executive Committee Deb Staudinger, Coordinator, B&WOG Generic-License Renewal Program The Commission emphasized the importance of having a stable-regulatory process for considering license renewal applications.

In this regard, the Commission noted the significant number of policy innues that have arisen in the implementation of Part 54, and the need for the prompt dedication of senior level management; attention to resolving these issues.

To accomplish this, the Commission endorsed the staff's recommendation to assemble a team of senior managers to review the license renewal rule and the agency's current approach to implementing this rule.

Specifically, the Commission is interested in having the1 senior management team review focus on, among others, the following issues:

1.

an assessment of the significance of the issuance of a new or " renewed" (rather than an amended) license in_ determining what kind of review the NRC should conduct and what kind of substantive technical requirements should be imposed as-a condition of the license renewal; 2.

a review of the scope of the current definition of systems, structures and components (SSCs) important to license renewal, focusing on -- (1) options for greater harmonization of this definition with the scope of SSCs-covered by the maintenance rule; and (ii) the staff's interpretation of the part of this definition extending to

"(ajl1 sscs subject to operability requirements contained in the facility technical specifications limiting conditions for operation", and the options for how this criteria might be applied (e.o.,

limiting the focus to structures and components necessary to mitigate or prevent design basis events);

3.

a review of the scope of the current definition of " age-related degradation unique to license renewal" (ARDULR) and, in particular -- (i) a review of the staff's approach to interpreting that part of the definition which states that ARDULR includes degradation'"...(w] hose effects were not explicitly identified and evaluated by the. licensee for the period of. extended operation and the evaluation found (Egg 10 CFR 54.3 (2)) ; and -(ii) an acceptable by the NRC assessment of whether, and if so, to what extent, fatigue and environmental qualification constitute ARDOLR; 4.

an assessment of the relationship between the license renewal process and the requirements of the maintenance-

s

. rule,-including recommendations on how the agency might achieve greater harmonization and integrationLof those two-rulesr_the evaluation should specifically include an assessment of the merits of permitting reliance on the maintenance rule in a fashion that would obviate the need to undertake an analysis to identify all age-related degradation mechanisms for each structure or component necessary for the performance of a required function.

5.

the resources (FTE and contractor support) expended in the last 2 fiscal years on the license renewal effort.

6.

an assessment of the feasibility of developing methods to-screen and select-SSCs within the license renewal scope for what aging management is appropriate during the renewed license period.

For example, such screening and selection might be based on the concept of short lived versus long lived SSCs.

Short lived SSCs (seals, gaskets, batteries, etc.) either have proven and demonstrated inspection and replacement programs or could be addressed under the maintenance rule implementation.

Long lived SSCs-(vessels, steam generators, cables, reactor coolant boundaries, passive structures, etc.) would be addressed during the renewed license period.

With respect to each of the foregoing issues, together with any-other issues identified by the senior management team, staff' should present a comprehensive discussion of each such issue, including the staff's recommendation for how each such issue should be addressed and whether modifications to NRC regulations are necessary to permit the-approach _being recommended.

The senior management team should complete its review and submit its recommendations on the forogoing-issues-to the Commission for 1esolution by February 19, ?.993.

The Commission desires to be briefed on the recommendations of the Senior management-team befcre the end of February 1993.

(EDO)

(SECY Suspense:

2/19/93) cc:

The Chairman Commissioner Rogers Commissioner Curtiss Commissioner.Remick commissioner de Planque OIG Office Directors, Regions, ACRS, ACNW (via E-Mail)

OP, SDBU/CR, ASLBP (via FAX)

PDR - Advance DCS - P1-24

-