U.S. NUCLE AR REGULATORY COMMISSloN CERTIFICATE OF COMPLIANCE 10 CFR 71 For Rad.oactive Materials Packar;es 6206 3

USA /6206/AF 1

1.(e) Tot $

o. Pages 1.(al Certificato Number 1.(b) Revision No.

1.(c) Packaos identification No.

1.(d) Pages No.

IN

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and

  • CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulatio*:, (46 CF R 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, rneets the safety standards set forth in Subpert C of Title 10, Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions /'

e 2.(c)

This certificate does not relieve the consignor from compliancs with any reauirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or applicatiort-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

The Babcock & Wilcox Company The Babcock & Wilcox Company application dated P. O. Box 800 February 27s 1980, l

Lynchburg, VA 24505 3.tc)

Docket No.

71-6206

4. CONDITIONS This certificate is. conditional upon the fulfilling of the requirements of Subart D of 10 CFR 71, as applicable, and the conditions specified in itsm 5 below.

G. Descripton of Packaging and Authorized Contents, Model Nurnber, Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model No.: Model B (2) Description A fuel assembly shipping container consisting of a steel strong-backa clamping assembly, shock mounted to a steel outer container.

Two, 3/16-inch thick, 8-5/8 inches high and full length stainless steel plates containing 1.5% minimum boron are positioned between adjacent fuel assemblies. The outer container is approximately i

40-inches in diameter by 200-inches long.

(3) Drawings The container is constructed in accordance with The Babcock &

Wilcox Company Drawing Nos. PE-52F, Revision 0;.PE-53F, Revision 0; and PE-54F, Revision 0.

l 8003280 6 7 9

o Page 2 - Certificate No. 6206 - Revision No. 3 - Docket No. 71-6206 5.

(b) Contents (1) Type and form of material U0i sintered pellet diameter 0.30 inch to 0.60 inch.

Uranium may be enriched to a maximum 4.05 w/o in the U-235 isotope. The pellets are clad in minimum 0.020-inch thickness zircalloy or minimum 0.016-inch thickness stainless steel rods. The rods are assembled into fuel assemblies with a maximum cross section of 8.6-inch by 8.6-inches. The void volume within the fuel assembly in the shall not exceed two (2) times the volume of U02 fuel assembly.

(2) Maximum quantity of material per package Two (2) fuel assemblies containing not more than 18.8 kg U-235 per assembly.

(c) Fissile Class III Maximum number of packages per shipment Twenty (20) 6.

Each fuel assembly shall be unsheathed or shall be enclosed in an unsealed, polyethylene sheath which will not extend beyond the ends of the fuel assembly. The ends of the sheath shall not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assembly.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

8.

Expiration date: March 31,1985.

REF_ERENCE The Babcock & Wilcox Company application dated February 27,1980 (complete).

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

    • l Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety i