ML20125D945

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Containment Purge Sys & Containment Venting Sys So That Evaluation of Electrical Override/Bypass Aspects of Containment Purge Matter Can Be Completed on Schedule
ML20125D945
Person / Time
Site: Point Beach, Prairie Island  
Issue date: 12/17/1979
From: Lainas G
Office of Nuclear Reactor Regulation
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8001210284
Download: ML20125D945 (3)


Text

.

1

( 71

y-w DISTRIBUTION

Central Files NRC PCR PSB Reading DEC l 7 1979 MEMORNICUl1 FOR:

A. Senwencer, Chief

~

Operating Reactors Branch il Division of Operating Reactors FR0!i:

G. Lainas, Chief Plant Systems Branen Division of Operating Reactors

SUBJECT:

RECUEST FOR ADDITIONAL INFORMATI0tl - C0tiTAINfCT PURGE SYSTE.'1 - PRAIRIE ISLAtlD UtlITS 1 & 2 (TAC 10156)

Plant : lame: Prairie Island Units 15 2 Cocket sics. : 50-282/306 Project Manager:

M. Grotenhuis Review Status: Awaiting Infor ation Plant Systems Branch has identified the enclosed additional information as being required within 30 days in order that we can conolete our evaluation of the electrical override / bypass aspects of the containment purge matter en senedule.

\\s G. Lainas, Chief Plant Systems Branen Division of Operating Reactors

Contact:

R. Scnoll, X27152 Enclosure :

Request for Additional Information cc w/ enclosure:

D. Eisennut J. Xerrigan W. Gamill G. Knighton 90023208 L. Nicnols V. Noonan G. Lainas F. Wi tt E. Reeves J..Zudans E. Adensam J. Kni gh, t,

('i m

n 2

m._m.

.D.ioUI' $

..........[...[.)...008.;

... 00 R :.RSE/.SL..

k.S.SLS.C..

.. 1....

-L..'Sh um......

.gS.cA

..gh...

..oIgn.d.L,....

..g..ai.n a s.......,

0

..Lk. 3.G9...

.i.>...l.. L.G.9.. 0..l.009...

m, a u,<,.,e m au, 80012]o 2 b

Enclosure REOUEST FOR ADDITIONAL INFORMATION FOR CONTAINMENT PURGE SYSTEM AND CONTAINMENT VEINTING SYSTEM FOR PRAIRIE ISLAND UNITS 1 & 2 00CXET NOS. 50-282/306 1.

With the exception of the containment ventilation isolation (CVI) system, the docketed information as to the design of Engineered Safety Features (ESF) does not adequately address the following a reas. Please discuss how your ESF design confoms with each:

1 - The overriding

  • of one type of safety actuation signal (e.g.,

radiation) should not cause the blocking of any other type of safety actuation signal (e.g., pressure) to the isolation valves.

2 - Sufficient physical features (e.g., key lock switches) should be provided to facilitate adequate administrative controls.

3 - The system-level annunciation of the overridden status should be provided for the containment isolation system and for every safety system impacted when an override is active.

4 - Diverse signals should be provided to initiate isolation of the containment ventilation syste;n.

Specifically, containment high radiation, safety injection actuation, and containment high pressure should automatically initiate Containment Ventilation Isolation (CVI).

5 - The instrumentation and control systems provided to initiate ESF should be designed and qualified as safety-grade equipment.

6 - The overriding or resetting

  • of the isolation actuation signal should not cause the automatic motion of any ESF valve.
  • The following cefinitions are given for clarity of use in this issue:

Override - the signal is still present, and it is blocked in order to

^

perform a function contrary to the signa 1; Reset - the signal has come and gone, and the circuit is being cleared to return to the normal condition.

90023209-

~,

,y.

. 2.

Provide the process and instrumentation (P&ID) and schematic drawings for your purge and vent system and control room heating, ventilation and air conditioning system.

3.

With regard to Criterion 4 of question 1 above, justify not providing for containment ventilation isolation on high containment pressure.

4.

With regard to Criterion 5 of question 1 above, please indicate if the radiation monitors that initiate CVI are Class IE or not.

If they are not justify their use for a required safety function.

  • i-

'90023210

!