k 1

h

)

POWER AUTHORITY OF THE STATE OF NEW YORK to CoLUMeus CIRCLE

'NEW YORK. N. Y. loo 19

, J f.t ) 397 6200 eggs u y

.e + a r Joe 8N 9.DYSON crema tises =pricts JOHN W POSTCN GEORQt L. INGALLS i,,

,gg.e, viCf CaatAMAN or powg4 satsattCNS 41CHARO M.FLYNN JCSEP

.AC IECER January 9, 1980

'Z*Ay ' ""

nescar i mb oNu r=cac iC< a.Cuanx JPN-80-2 us o A e,ge,,,m. SCI AL

'"*"hth',"U......,

Director of Nuclear Reactor Regulation

' ' ' " ' " ^ ' * " '

United States Nuclear Regulatory Commission Washington,~D.

C.

20555 Attention:

Mr. Thomas A.

Ippolito Operating Reactors Branch No. 3 Division of Operating Reactors

Subject:

James A.

FitzPatrick Nuclear Power Plant Docket No. 50-333 Fuel Rod Strain and Flow Blockage Models

Dear Sir:

This letter is in response to your letters of November 9, 1979 and November 27, 1979, requesting confirmation that the fuel rod strain-flow blockage models used on the FitzPatrick Plant are conservative with respect to the NRC's model derived from ORNL Multi-Rod Burst Test Facility data.

Since we do not technically have or use our own models in this area, the following discussion pertains to the use of General Electric Company approved models in association with the operation of the FitzPatrick Plant.

Via both your letters of November 9 and 27, and our corres-pondence from GE, we are aware of the review ef fort GE has applied to this issue.

We are also aware of the communications between GE and the NRC on this subject, and we herein affirm that based on our correspondence from GE, that it is our understanding that over the operating range of interest pertinent to the FitzPatrick Plant, that the models applied by GE and approved by the NRC are of a conservative level equivalent to the NRC model.

Very truly-yours, 90017s47 Paul J.'

Early Assistant Chief Engineer-Projects t 60

\\

80 0134o 22P