Summary of 831220 Meeting W/Util & S&W in Bethesda,Md Re Util Schedules,Plans & Progress in Resolving Electrical Separation Issues Involved in Complying W/Criteria of Reg Guide 1.75,Rev 2
ML20125C797
Person / Time
Site: Beaver Valley
Issue date: 05/24/1985
From: Lazo L
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
RTR-REGGD-01.075, RTR-REGGD-1.075 NUDOCS 8506120162
Download: ML20125C797 (6)


Text

_.

d UNITED STATES f

g NUCLEAR REGULATORY COMMISSION 5

j WASHINGTON, D. C. 20555 W 2 41985
  • as.*

Docket No.: 50-412 APPLICANT:

Duquesne Light Company FACILITY:

Beaver Valley Power Station, Unit 2

SUBJECT:

PHYSICAL SEPARATION CRITERIA A meeting was held with Duquesne Light Company (DLC) on Tuesday, December 20, 1983 at NRC Headquarters in Bethesda, Maryland. DLC was accompanied by representatives of Stone & Webster Engineering Corporation. The NRC was represented by members of the Division of Licensing, the Division of Systems Integration and Region I.

A list of attendees is included as Enclosure 1.

The purpose of the meeting was to discuss DLC's sc.hedules, plans, and progress in resolving electrical separation issues involved in complying with the criteria of. Regulatory Guide 1.75, Revision 2 (R.G. 1.75, Rev.2). The applicant's presentation included an outline of their program for implementation of IEEE Standard 384-1974 as augmented by R.G. 1.75, Rev.2.

The program's objectives included identifying preventative actions, such as modified installation practices and training, to eliminate future occurrences of unacceptable separation distances.

The program included revising the Electrical Cable and Raceway Criteria (2BVM-41) and the Electrical Installation Specification (2BVS-931) to include design provisions for meeting separation requirements.

Region I noted that earlier discussions with the applicant had indicated that they would be relying mostly on testing to demonstrate that-reduced separations were acceptable. However, that has changed significantly and now the applicant's preferred order of separation design provisions is (1) Spatial separation, (2) Tray covers /

bottoms, (3) Enclosed raceways, (4) Barriers, (5) Protective wraps / coverings, and finally (6) Analysis and/or tests.

DLC has entered into an agreement with Wyle Testing Laboratories to perform plant specific tests and analyses.

The NRC inquired as to what type of analysis was expected to be performed.

DLC noted I

that in' general analyses would be performed to confirm design adequacy in terms of the IEEE 384-1974 Standard, but there was the possibility that.s me single failure event analysis would be performed to demonstrate that minimum safeguards for safe plani; control and shutdown would remain available for the design con-4 figurations being addressed.

The staff warned that an NRC review of this type of single failure analysis might be difficult and take some time. The staff f

suggested that it be used sparingly and when used, identified to the staff as soon as possible.

Some of the graphics presented at the meeting depicting the separation design modifications did not, in the NRC's opinion, correspond with c

IEEE 384-1974 depictions.

H 8506120162 850 7-O

,,g2 r

b

i 0

2_

The NRC Power Systems reviewer referring to instrumentation panels, asked if the requirement for 6 inch spacing between safety and non-safety circuits within panels or the inclusion of flexible conduit, or a barrier would be met. DLC said they would consult Westinghouse.and respond to our question at a later date.

The NRC also requested an updated schedule and a copy of the presentation made at the meeting be submitted by January 16, 1984. DLC committed to supplying revised copies that would reflect any changes resulting from the day's dis-cusion.

The status of the plant as presented by DLC is that most cases of less than minimum required separation involved vertical separation distances and were between a single division and a non-class 1E raceway. Most violations were noted in the control building, cable tunnel, and cable vault.

At the conclusion of the meeting, the staff expressed the view that the timely completion of activities was critical to the success of the progran including the revisions to the Electrical Installation Specification and the development of a detailed tracking system identifying all spatial nonconformances and how they are to be resolved.

/Jl Lisamari'e Lazo, Project Manager Licensing Branch No. 3 Division of Licensing

Enclosures:

As stated cc: See next page O

DLt

  1. 3 Llazo ghton 5/20/85 5/ /85 J

Beaver Valley Mr. John J. Carey-Vice President, Nuclear Duquesne Light Company Robinson Plaza Building, No. 2, Suite 110 PA Route 60

~Pittsburgh, Pennsylvania 15205 Gerald Charnoff, Esq.

Mr. R. E. Martin, Manager Engineering Jay E. Silberg, Esq.

Beaver Valley Two Project Shaw, Pittman, Potts & Trowbridge

~Duquesne Light Company 1800 M Street, N.W.

Robinson Plaza Building No. 2, Suite 110 Washington, DC 20036 PA Route 60 Pittsburgh, Pennsylvania 15205

'Mr. C. W. Ewing, Quality Assurance Zori Ferkin Manager Assistant Counsel Quality Assurance Department Governor Energy Council Duquense Light Company 1625 N. Front Street.

P. O. Box 186 Harrisburg, PA 15105 Shippingport, Pennsylvania 15077 Mr. John J. Carey Vice President, Nuclear Duquense Light Company Director, Pennsylvania Emergency P. O. Box 4 Management Agency Pittsburgh,' Pennsylvania 15205 Room B-151 Transportation & Safety Building Harrisburg, Pennsylvania 17120 Mr. T. J. Lex Mr. Thomas Gerusky Westinghouse Electric Corporation Bureau of Radiation Protection

. Power Systems PA Department of Environmental P. 0. Box 355 Resources Pittsburgh, Pennsylvania 15230 P. O. Box 2063 Harrisburg, Pennsylvania 17120 Mr. P. RaySircar Stone & Webster Engineering Corporation BVPS-2 Records Management Supervisor P. O. Box 2325 Duquesne Light Company Boston, Massachusetts 02107 Post Office Box 4 Shippingport, Pennsylvania 15077 Mr. Glenn Walton U. S. NRC John A. Lee, Esq.

P. O. 181 Duquesne Light Company Shippingport, Pennsylvania 15077 1 0xford Centre 301 Grant Street Mr.' Thomas E. Murley, Regional Admin.

Pittsburgh, Pennsylvania 15279 U. S. NRC, Region I 631 Park Avenue LKing ~ of Prussia, Pennsylvania 15229 O

k.

r.

. Mr. E. F. Kurtz, Jr., Manager Regulatory Affairs Beaver Valley Two Project Duquense Light Company Robinson Plaza Buidling No. 2 Suite #210 PA Route 60 Pittsburgh,~ Pennsylvania 15205 S.

na W

e

v,

.c i

MEETING: December 20, 1983 ATTENDEES NRC L. Lazo R. Paolino J. Knox F. Burrows G. Walton L. Cheung C. Anderson APPLICANT M. Siegel, DLC J. Konkus, DLC J. Hultz, DLC C. Hill, DLC

.C. Wilbur, SWEC J. Dolan, SWEC J. Weinberger, SWEC R. Matherwiez, SWEC J. Curtin, SWEC P. - RaySircar, SWEC

.C. Richardson, SWEC 5

i t

Se

g g 4 $8$

MEETING

SUMMARY

DISTRIBUTION Docket:No(s): c 50-412 NRC PDP.

'~

Local PDR NSIC PRC Syster LB3 Reading Attorney, OELD GWKnighton Project Manager LLazo JLee NRC PARTICIPANTS L. Lazo R. Paolino J. Knox F. Burrows G. Walton L. Cheung

~

C. Anderson bec: Applicant & Service List No L.