ML20125B040

From kanterella
Jump to navigation Jump to search
Responds to Re Number of U Dioxide Pellets in Each Zircaloy Fuel Rod at Tmi.Approx 205 Pellets in Each Rod.Drawing of Fuel Rod Design Encl
ML20125B040
Person / Time
Site: Crane 
Issue date: 08/29/1979
From: Schroeder F
Office of Nuclear Reactor Regulation
To: Nellis R
AFFILIATION NOT ASSIGNED
Shared Package
ML20125B043 List:
References
NUDOCS 7910190319
Download: ML20125B040 (2)


Text

-

  • . o. +

e-m to A

g

~

k Distribution AUG 2 9.19'9

/

Central Files ry Schultz e l

NRR R/F RPDenise i.

CPB R/F FSchroeder 1

PDR Congressional Affair ~s (with incomina)

PVitale

'i DSS R/F KKriiel ROMeyer Mr."N@5'8"A.Mellis Scottsdale Christian Home 3339 N. Civic Center Plaza g y n y,.m..,,,...- -

,Q [

Scottsdale, Arizona 85251 L M A,,,,,,,_, ; j

Dear Mr. Nellis:

In answer to your inquiry of August 15, 1979, there are approximately-205 uranium' dioxide pellets in each Z.ircaloy fuel rod at TMI-2. The exact number for any individual rod may vary by plus or iginus a few pellets since the fabricated pellet length dimension is not a rigid specification. The 205 value is based on a uniform pellet length of 0.700 inches. Enclosed is a copy of Figure 4.2-2 from the TMI-2 Final l

Safety Analysis Report that shows the fuel rod design. The dirnensions for the various components were provided in our previous letter of

. July 20,1979.

I trust that the above information satisfies your inquiry. Please let me know if additional information is needed.

Sincerely,

(.N Frank Schroeder, Acting Director Division of Systems Safety

Enclosure:

As stated cc: The Honorable Dennis DeConcini e-

...Dg/.GRe

.. DSS,/,gP

,,, DSS /GRQ

,,ps,5,/,6Q/,85

,,,,DS,S,[,Mj,,,,,,

  • = = *
g..

.tJRff9Ebniny... M.M.ey............K Ka ie l..........

..REQe.nj.s.e..

...ES.ch[qe. der..

--* s

,.08/ f/.7.9..

.#.8M'fd.9.....

08./2[G 9,,,,

. 08,/,f,A.69,,

08/,,(,f/,79 f

.m w NBC PORM 318 (9 74) NRCM 0240 k u.s. neve aama n,....,ene areees s i e r e. se e.,..

7910100%

i 97 ENO CAP 10Eht!FIC A110N M Ak1 14PICAL ENO C AP SE At # ELD f

ITPIC AL Zh fr 2 trPER GA5 l

M UPPEG SPRING SPACER lle==}-

tre ll N.]

l' 4

s.]

N

\\

RIGIO SP ACERS C

\\

ftPICAL QEM

\\l/

/ \\

'\\ /

)

V

AJ l'F

, \\,

FUEL PELLET STACK

\\ /

x RIGIC SPACER $

[

h. f fYPICAL l

LOaER Ga$ Pt(NUM 6

l fD n

b

.n:.

LC.E.,.. sPam, Ng.

,I i

0r$0 I

91 (a/ V-PREPRESSURIZED FUEL ROD THREE MILE ISLAND NUCLEAR STATION UNIT 2 y........

. lO l

FIGURE 4.2-2

-c