April 2020 Revision 20B NAC-UMS Universal MPC System SAFETY ANALYSIS REPORT Supplement to Damaged BWR Amendment 8 Non-Proprietary Version Docket No. 72-1015 A
NAC INTERNATIONAL Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770~447-1144, Fax 770-447-1797, www.nacJntl.com
- to ED20200056 Page 1 of2 Supporting Calculation for the NAC-UMS FSAR Supplement to Damaged BWR Amendment 8 Revision 20B (Docket No 72-l O 15)
NAC International April 2020
- to ED20200056 Page 2 of2 List of Calculations
- 1. EA790-2521, Revision 1 CALCULATION WITHHELD IN ITS ENTIRETY PER 10 CFR 2.390
- to ED20200056 Page I of2 List of Changes for the NAC-UMS FSAR Supplement to Damaged BWR Amendment 8 Revision 20B (Docket No 72-1015)
NAC International April 2020
- to ED20200056 Page 2 of2 List of Changes for the NAC-UMS FSAR, Revision 20B The List of Effective Pages and the Chapter Table of Contents, List of Figures and List of Tables have been revised accordin 1 to reflect the list of chan es detailed below, if needed.
Chapter 1 Pa e 1.8-2 Modified Section 1.8.1 where indicated.
Chapter 2 - no changes Chapter 3 Pages 3.9-12 thru 3.9-14 Pages 3.9-15 thru 3.9-17 Modified and added text at the end of Section 3.9.2.2 where indicated.
Text flow chan es.
Chapter 4 - no changes Chapter 5 - no changes Chapter 6 - no changes Chapter 7 - no changes Chapter 8 - no changes Chapter 9 - no changes Chapter 10 - no changes Chapter 11 - no changes Chapter 12 - no changes Chapter 13 - no changes
- of ED20200056 Page 1 of2 List of Drawing Changes for the NAC-UMS Supplement to Damaged BWR Amendment 8 Revision 20B (Docket No 72-1015)
NAC International April 2020
- of ED20200056 Page 2 of2 NAC PROPRIETARY INFORMATION REMOVED List of Drawing Changes, NAC-UMS SAR, Revision 20B Drawing 790-601, Sheet l, Revision 2P Sheet I:
Drawing 790-601, Sheet l, Revision lNP Sheet I:
I. Clouded out B.O.M. details indicating them as proprietary.
- 2. Clouded out Note details indicating them as proprietary.
- 3. Clouded out Assembly 99 identification balloon and title.
- to ED20200056 Page 1 of 1 FSAR Changed Pages for the NAC-UMS Supplement to Damaged BWR Amendment 8 Revision 20B (Docket No 72-1015)
NAC International April 2020
April 2020 Revision 208 NAC-UMS Universal MPC System FINAL SAFETY ANALYSIS REPORT for the UMS Universal Storage System Non-Proprietary Version Docket No. 72-1015 ANAC fwl INTERNATIONAL Atlanta Corporate Headquarters: 3930 East Jones Bridge Road, Norcross, Georgia 30092 USA Phone 770-447-1144, Fax 770-447-1797, www.nacintl.com
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages Chapter 1 1.5-4........................................ Revision 11 1-i.............................................. Revision 3 1.5-5.......................................... Revision 8 I-ii.......................................... Revision 10 1.5-6 thru 1.5-7......................... Revision 0 1-1............................................ Revision 0 1.5-8.......................................... Revision 6 1-2............................................ Revision 5 1.5-9........................................ Revision 13 1-3............................................ Revision 8 1.5-10........................................ Revision 0 1-4 thru 1-6.......................... Revision 19A 1.5-11........................................ Revision 3 1-7............................................ Revision 8 1.5-12 thru 1.5-16..................... Revision 0 1-8 thru 1-9.......................... Revision 19A 1.5-17........................................ Revision 3 1.1-1.......................................... Revision 3 1.5-18 thru 1.5-20..................... Revision 0 1.1-2.......................................... Revision 4 1.5-21........................................ Revision 6 1.1-3.......................................... Revision 3 1.5-22........................................ Revision 4 1.1-4.......................................... Revision 0 1.5-23 thru 1.5-26..................... Revision 0 1.2-1.......................................... Revision 3 1.5-27........................................ Revision 3 1.2-2..................................... Revision 19A 1.5-28........................................ Revision 8 1.2-3.......................................... Revision 8 1.5-29........................................ Revision 0 1.2-4.......................................... Revision 3 1.5-30........................................ Revision 8 1.2-5 thru 1.2-10.................. Revision 19A 1.5-31 thru 1.5-32..................... Revision 0 1.2-11 thru 1.2-12..................... Revision 6 1.5-33........................................ Revision 3 1.2-13........................................ Revision 8 1.5-34........................................ Revision 5 1.2-14 thru 1.2-20..................... Revision 6 1.5-35........................................ Revision 0 1.2-21................................... Revision 19A 1.5-36........................................ Revision 3 1.2-22 thru 1.2-23..................... Revision 6 1.5-37 thru 1.5-38................... Revision 10 1.2-24................................... Revision 19A 1.5-39 thru 1.5-43..................... Revision 0 1.2-25........................................ Revision 6 1.5-44........................................ Revision 8 1.2-26................................... Revision 19A 1.5-45 thru 1.5-46..................... Revision 0 1.2-27........................................ Revision 6 1.5-4 7........................................ Revision 3 1.2-28...................................... Revision 10 1.5-48........................................ Revision 8 1.2-29........................................ Revision 6 1.5-49 thru 1.5-54..................... Revision 0 1.3-1..................................... Revision 19 A 1.6-1.......................................... Revision 8 1.3-2.......................................... Revision 5 1.7-1.......................................... Revision 3 1.3-3.......................................... Revision 4 1.7-2 thru 1.7-3......................... Revision 4 1.4-1 thru 1.4-2......................... Revision 0 1.8-1..................................... Revision 19A 1.5-1.......................................... Revision 0 1.8-2...................................... Revision 20B 1.5-2........................................ Revision 11 1.5-3.......................................... Revision 0 32 drawings (see Section 1.8)
.1
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages (continued)
Chapter 2 2.5-1 thru 2.5-2......................... Revision 3 2-i............................................. Revision 3 2-ii............................................. Revision 6 Chapter 3 2-iii............................................ Revision 3 3-i............................................. Revision 3 2-iv.......................................... Revision 11 3-ii........................................ Revision 19A 2-1............................................. Revision 8 3-iii thru 3-viii........................... Revision 3 2-2........................................ Revision 19A 3.1-1 thru 3.1-2......................... Revision 3 2-3............................................. Revision 3 3.1-3..................................... Revision 19A 2.1-1..................................... Revision 19A 3.1-4 thru 3.1-7......................... Revision 3 2.1.1-1 thru 2.1.1-4................... Revision 8 3.2-1.......................................... Revision 0 2.1.2-1 thru 2.1.2-2.............. Revision 19A 3.2-2.......................................... Revision 3 2.1.2-3....................................... Revision 8 3.2-3 thru 3.2-4.................... Revision 19A 2.1.3-1 thru 2.1.3-4................... Revision 8 3.3-1 thru 3.3-15....................... Revision 3 2.1.3-5....................................... Revision 3 3.3-16........................................ Revision 8 2.1.3-6....................................... Revision 8 3.4.1-1.................................. Amendment 2 2.1.3-7 thru 2.1.3-8................... Revision 3 3.4.1-2....................................... Revision 4 2.1.3-9....................................... Revision 5 3.4.1-3 thru 3.4.1-4.............. Amendment 2 2.1.3-10 thru 2.1.3-14............... Revision 3 3.4.1-5....................................... Revision 3 2.2-1..................................... Amendment 1 3.4.1-6 thru 3.4.1-8................... Revision 4 2.2-2 thru 2.2-3......................... Revision 0 3.4.1-9..................................... Revision 11 2.2-4.......................................... Revision 5 3.4.1-10 thru 3.4.1-12............... Revision 3 2.2-5.......................................... Revision 3 3.4.2-1....................................... Revision 8 2.2-6 thru 2.2-10....................... Revision 0 3.4.2-2....................................... Revision 4 2.2-11........................................ Revision 3 3.4.3-1....................................... Revision 4 2.3-1 thru 2.3-2....................... Revision 11 3.4.3-2 thru 3.4.3-3................... Revision 3 2.3-3 thru 2.3-4......................... Revision 3 3.4.3-4....................................... Revision 0 2.3-5 thru 2.3-8.................... Revision 19A 3.4.3-5 thru 3.4.3-22................. Revision 3 2.3-9.......................................... Revision 3 3.4.3-23 thru 3.4.3-26............... Revision 6 2.3-10........................................ Revision 0 3.4.3-27..................................... Revision 3 2.3-11........................................ Revision 5 3.4.3-28..................................... Revision 4 2.3-12 thru 2.3-15................... Revision 11 3.4.3-29 thru 3.4.3-98............... Revision 3 2.3-16 thru 2.3-17................ Revision 19A 3.4.4-1....................................... Revision 0 2.3-18 thru 2.3-19................... Revision 11 3.4.4-2 thru 3.4.4-7................... Revision 3 2.3-20................................... Revision 19A 3.4.4-8 thru 3.4.4-9................. Revision 12 2.4-1.......................................... Revision 3 3.4.4-10..................................... Revision 0 2.4-2 thru 2.4-4......................... Revision 0 3.4.4-11 thru 3.4.4-18............... Revision 3 2
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages (continued) 3.4.4-19..................................... Revision 8 4.1-6.......................................... Revision 7 3.4.4-20..................................... Revision 3 4.1-7 thru 4.1-8......................... Revision 5 3.4.4-21 thru 3.4.4-38............... Revision 0 4.2-1 thru 4.2-3......................... Revision 3 3.4.4-39 thru 3.4.4-48............... Revision 3 4.2-4.......................................... Revision 0 3.4.4-49 thru 3.4.4-51............... Revision 0 4.2-5.......................................... Revision 4 3.4.4-52 thru 3.4.4-64............... Revision 3 4.2-6.......................................... Revision 0 3.4.4-65..................................... Revision 0 4.2-7.......................................... Revision 7 3.4.4-66 thru 3.4.4-69............... Revision 3 4.3-1 thru 4.3-3......................... Revision 3 3.4.4-70 thru 3.4.4-74............... Revision 0 4.4-1.......................................... Revision 3 3.4.4-75 thru 3.4.4-77............... Revision 3 4.4.1-1....................................... Revision 3 3.4.5-1....................................... Revision 3 4.4.1-2.................................. Revision 19A 3.5-1.......................................... Revision 4 4.4.1-3....................................... Revision 7 3.6-1.......................................... Revision 8 4.4.1-4 thru 4.4.1-7................... Revision 0 3.6-2.......................................... Revision 4 4.4.1-8.................................. Amendment 2 3.6-3.......................................... Revision 8 4.4.1-9....................................... Revision 5 3.6-4 thru 3.6-5......................... Revision 3 4.4.1-10 thru 4.4.1-17............... Revision 3 3.6-6..................................... Amendment 1 4.4.1-18................................ Revision 19A 3.6-7 thru 3.6-8......................... Revision 3 4.4.1-19 thru 4.4.1-22............... Revision 3 3.7-1 thru 3.7-2......................... Revision 3 4.4.1-23 thru 4.4.1-24.......... Revision 19A 3.7-3 thru 3.7-4......................... Revision 8 4.4.1-25 thru 4.4.1-26............... Revision 3 3.8-1........................................ Revision 11 4.4.1-27..................................... Revision 4 3.8-2 thru 3.8-20....................... Revision 9 4.4.1-28..................................... Revision 5 3.8-21 thru 3.8-26................... Revision 11 4.4.1-29..................................... Revision 3 3.9-1 thru 3.9-11.................. Revision 19A 4.4.1-30..................................... Revision 4 3.9-12 thru 3.9-17................. Revision 20B 4.4.1-31 thru 4.4.1-34............... Revision 3 4.4.1-35................................ Revision 19A Chapter 4 4.4.1-36 thru 4.4.1-37............... Revision 3 4-i thru 4-ii............................... Revision 3 4.4.1-38................................ Revision 19A 4-iii....................................... Revision 19A 4.4.1-39 thru 4.4.1-40............... Revision 3 4-iv............................................ Revision 3 4.4.1-41 thru 4.4.1-43............... Revision 4 4-v....................................... Revision 19A 4.4.1-44 thru 4.4.1-49............... Revision 3 4-vi............................................ Revision 8 4.4.2-1....................................... Revision 0 4.1-1..................................... Revision 19A 4.4.3-1....................................... Revision 8 4.1-2 thru 4.1-3......................... Revision 8 4.4.3-2 thru 4.4.3-5.............. Revision 19A 4.1-4.......................................... Revision 0 4.4.3-6 thru 4.4.3-13................. Revision 3 4.1-5.......................................... Revision 4 4.4.3-14 thru 4.4.3-15............... Revision 5 3
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages (continued) 4.4.3-16..................................... Revision 3 5.2-1 thru 5.2-36....................... Revision 8 4.4.3-17..................................... Revision 4 5.3-1 thru 5.3-10....................... Revision 3 4.4.3-18 thru 4.4.3-22............... Revision 3 5.3-11 thru 5.3-12..................... Revision 4 4.4.4-1....................................... Revision 0 5.3-13 thru 5.3-21..................... Revision 3 4.4.5-1....................................... Revision 8 5.3-22 thru 5.3-23..................... Revision 4 4.4.5-2 thru 4.4.5-2................... Revision 5 5.3-24........................................ Revision 3 4.4.5-3.................................. Revision 19A 5.3-25 thru 5.3-26..................... Revision 4 4.4.5-4....................................... Revision 8 5.3-27 thru 5.3-32..................... Revision 3 4.4.5-5.................................. Revision 19A 5.4-1 thru 5.4-4......................... Revision 3 4.4.6-1....................................... Revision 0 5.4-5.......................................... Revision 7 4.4.7-1....................................... Revision 3 5.4-6 thru 5.4-27....................... Revision 3 4.5-1.......................................... Revision 5 5.5-1.......................................... Revision 8 4.5-2 thru 4.5-3......................... Revision 4 5.5-2.......................................... Revision 3 4.5-4..................................... Amendment 2 5.5-3 thru 5.5-4......................... Revision 7 4.5-5.......................................... Revision 3 5.5-5 thru 5.5-7......................... Revision 3 4.5-6.......................................... Revision 4 5.5-8 thru 5.5-10....................... Revision 8 4.5-7.......................................... Revision 3 5.6-1..................................... Amendment 1 4.5-8.......................................... Revision 8 5.6.1-1....................................... Revision 4 4.5-9 thru 4.5-10....................... Revision 3 5.6.1-2.................................. Amendment 1 4.5-11 thru 4.5-16................ Amendment 2 5.6.1-3....................................... Revision 4 4.5-17........................................ Revision 7 5.6.1-4.................................. Amendment 1 4.5-18 thru 4.5-19..................... Revision 3 5.6.1-5....................................... Revision 4 4.6-1 thru 4.6-2......................... Revision 3 5.6.1-6 thru 5.6.1-8................... Revision 3 4.6-3.......................................... Revision 0 5.6.1-9 thru 5.6.1-10............ Amendment 1 4.6-4.......................................... Revision 8 5.6.1-11 thru 5.6.1-12............... Revision 8 5.6.1-13 thru 5.6.1-22.......... Amendment 2 Chapter 5 5.6.1-23 thru 5.6.1-24............... Revision 3 5-i............................................. Revision 8 5.6.1-25................................ Amendment 2 5-ii........................................ Revision 19A 5.6.1-26 thru 5.6.1-27............... Revision 3 5-iii............................................ Revision 8 5.6.1-28 thru 5.6.1-34.......... Amendment 2 _
5-iv thru 5-iv............................. Revision 3 5.7-1 thru 5.7-2......................... Revision 0 5-v........................................ Revision 19A 5.7-3.......................................... Revision 8 5-vi thru 5-viii........................... Revision 8 5.8-1..................................... Revision 19A 5-ix thru 5-x......................... Revision 19A 5.8.1-1 thru 5.8.1-4.............. Revision 19A 5.1-1........................................ Revision 12 5.8.2-1 thru 5.8.2-15............ Revision 19A 5.1-2 thru 5.1-12....................... Revision 7 5.8.3-1 thru 5.8.3-6.............. Revision 19A 4
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages (continued)
Chapter 6 6.8-1 thru 6.8-2.................... Revision 19A 6-i........................................... Revision 3 6.9-1 thru 6.8-66.................. Revision 19A 6-ii thru 6-x.......................... Revision 19A 6.1-1 thru 6.1-2......................... Revision 8 Chapter 7 6.1-3 thru 6.1-7.................... Revision 19A 7-i thru 7-ii................................ Revision 4 6.2-1.......................................... Revision 5 7.1-1 thru 7.1-2......................... Revision 8 6.2-2 thru 6.2-3......................... Revision 3 7.1-3.......................................... Revision 4 6.3-1 thru 6.3-2......................... Revision 3 7.1-4.......................................... Revision 8 6.3-3........................................ Revision 10 7.1-5.......................................... Revision 4 6.3-4 thru 6.3-6......................... Revision 3 7.1-6.......................................... Revision 8 6.3-7.......................................... Revision 7 7.1-7 thru 7.1-9......................... Revision 4 6.3-8.......................................... Revision 4 7.2-1.......................................... Revision 3 6.3-9 thru 6.3-18....................... Revision 3 7.2-2.......................................... Revision 8 6.4-1.......................................... Revision 4 7.3-1.......................................... Revision 8 6.4-2 thru 6.4-13....................... Revision 3 7.4-1.......................................... Revision 8 6.4-14 thru 6.4-15................ Revision 19A 7.5-1.......................................... Revision 4 6.4-16........................................ Revision 3 6.4-17........................................ Revision 0 Chapter 8 6.4-18 thru 6.4-40..................... Revision 3 8-i........................................ Amendment 1 6.5-1..................................... Revision 19A 8-ii............................................. Revision 5 6.5-2 thru 6.5-49....................... Revision 3 8-1 thru 8-2............................... Revision 5 6.5-50 thru 65-81................. Revision 19A 8.1-1.......................................... Revision 8 6.6-1..................................... Amendment 2 8.1.1-1....................................... Revision 8 6.6.1-1 thru 6.6.1-2................... Revision 8 8.1.1-2....................................... Revision 5 6.6.1-3.................................. Amendment2 8.1.1-3....................................... Revision 4 6.6.1-4....................................... Revision 4 8.1.1-4 thru 8.1.1-7................... Revision 8 6.6.1-5 thru 6.6.1-7................... Revision 8 8.1.1-8 thru 8.1.1-10................. Revision 5 6.6.1-8....................................... Revision 3 8.1.1-11..................................... Revision 6 6.6.1-9 thru 6.6.1-10............ Amendment 2 8.1.2-1 thru 8.1.2-2................... Revision 8 6.6.1-11..................................... Revision 8 8.1.3-1 thru 8.1.3-2................... Revision 8 6.6.1-12 thru 6.6.1-14.......... Amendment 2 8.2-1.......................................... Revision 6 6.6.1-15..................................... Revision 4 8.2-2.......................................... Revision 5 6.6.1-16 thru 6.6.1-21.......... Amendment 2 8.3-1.......................................... Revision 4 6.6.1-22..................................... Revision 3 8.3-2 thru 8.3-4......................... Revision 3 6.6.1-23 thru 6.6.1-24.......... Amendment 2 8.4-1.......................................... Revision 0 6.7-1 thru 6.7-30.................. Revision 19A 5
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 208 List of Effective Pages (continued)
Chapter 9 11-v........................................... Revision 3 9-i thru 9-ii........................... Revision 19A 11-vi..................................... Revision 19 A 9.1-1.......................................... Revision 4 11-vii thru 11-x......................... Revision 3 9.1-2.......................................... Revision 8 11-1........................................... Revision 0 9.1-3.......................................... Revision 4 11.1.1-1..................................... Revision 6 9.1-4.......................................... Revision 5 11.1.1-2..................................... Revision 3 9.1-5.......................................... Revision 4 11.1.1-3 thru 11.1.1-6............... Revision 0 9.1-6........................................ Revision 10 11.1.2-1..................................... Revision 6 9.1-7 thru 9.1-20.................. Revision 19A 11.1.2-2..................................... Revision 0 9.2-1.......................................... Revision 7 11.1.2-3..................................... Revision 3 9.2-2.......................................... Revision 9 11.1.3-1..................................... Revision 3 9.2-3.......................................... Revision 7 11.1.3-2 thru -11.1.3-3............ Revision 12 9.3-1.......................................... Revision 8 11.1.3-4 thru -11.1.3-16............ Revision 3 9.3-2.......................................... Revision 5 11.1.4-1 thru 11.1.4-2............... Revision 6 11.1.5-1 thru 11.1.5-2............... Revision 0 Chapter 10 11.1.6-1................................ Amendment 1 10-i thru 10-ii....................... Revision 19A 11.2-1................................... Amendment 1 10.1-1........................................ Revision 3 11.2.1-1 thru 11.2.1-7............... Revision 3 10.1-2........................................ Revision 6 11.2.2-1..................................... Revision 8 10.2-1 thru 10.2-2................ Revision 19A 11.2.3-1..................................... Revision 3 10.3-1 thru 10.3-3................ Revision 19A 11.2.3-2..................................... Revision 0 10.3-4........................................ Revision 0 11.2.4-1 thru 11.2.4-11............. Revision 3 10.3-5 thru 10.3-6..................... Revision 3 11.2.4-12................................. Revision 13 10.3-7........................................ Revision 0 11.2.4-13 thru 11.2.4-21........... Revision 0 10.3-8 thru 10.3-9..................... Revision 3 1.2.4-22 thru 11.2.4-24............. Revision 3 10.4-1 thru 10.4-2................ Revision 19A 11.2.4-25................................... Revision 7 10.4-3 thru 10.4-5..................... Revision 3 11.2.4-26 thru 11.2.4-27........... Revision 3 10.5-1................................... Amendment 1 11.2.5-1..................................... Revision 0 10.6-1 thru 10.6-3................ Revision 19A 11.2.6-1 thru 11.2.6-2............... Revision 3 10.7-1................................... Revision 19A 11.2.6-3................................... Revision 13 11.2.6-4..................................... Revision 0 Chapter 11 11.2.6-5..................................... Revision 3 11-i....................................... Amendment 1 ll.2.7-1..................................... Revision 6 11-ii........................................... Revision 3 11.2.7-2..................................... Revision 3 11-iii.......................................... Revision 5 11.2.8-1..................................... Revision 5 11-iv..................................... Revision 19A 11.2.8-2..................................... Revision 0 6
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B List of Effective Pages (continued) 11.2.8-3 thru 11.2.8-5............... Revision 3 11.2.8-6..................................... Revision 5 11.2.8-7..................................... Revision 3 11.2.8-8 thru 11.2.8-10............. Revision 5 11.2.8-11 thru 11.2.8-12......... Revision 13 11.2.9-1..................................... Revision 0 11.2.9-2 thrul 1.2.9-4................ Revision 3 11.2.9-5................................... Revision 13 11.2.9-6 thru 11.2.9-7............... Revision 3 11.2.10-1 thru 11.2.10-3........... Revision 0 11.2.10-4................................. Revision 13 11.2.11-1................................... Revision 0 11.2.11-2 thru 11.2.11-4........... Revision 3 11.2.11-5 thru 11.2.11-7........... Revision 0 11.2.11-8 thru 11.2.11-11......... Revision 3 11.2.11-12................................. Revision 0 11.2.11-13............................... Revision 13 11.2.11-14................................. Revision 3 11.2.12-1................................... Revision 0 11.2.12-2................................... Revision 7 11.2.12-3 thru 11.2.12-10......... Revision 3 11.2.12-11 thru 11.2.12-12....... Revision 0 11.2.12-13 thru 11.2.12-14....... Revision 3 11.2.12-15 thru 11.2.12-17..... Revision 12 11.2.12-18................................. Revision 0 11.2.12-19 thru 11.2.12-20....... Revision 3 11.2.12-21................................. Revision 0 11.2.12-22................................. Revision 3 11.2.12-23................................. Revision 0 11.2.12-24 thru 11.2.12-70....... Revision 3 11.2.12-71............................... Revision 13 11.2.13-1................................... Revision 6 11.2.13-2................................. Revision 13 11.2.13-3................................... Revision 0 11.2.14-1................................... Revision 8 11.2.14-2................................... Revision 3 7
11.2.15-1 thru 11.2.15-2........... Revision 3 11.2.15-3.............................. Amendment 1 11.2.15-4.............................. Amendment 2 11.2.15-5 thru 11.2.15-6........... Revision 8 11.2.15-7 thru 11.2.15-13.... Amendment 1 11.2.15-14thru 11.2.15-17....... Revision 3 11.2.15-18 thru 11.2.15-22.. Amendment 1 11.2.15-23 thru 11.2.15-24.. Amendment 2 11.2.15-25................................. Revision 4 11.2.15-26............................ Amendment 2 11.2.15-27............................ Amendment 1 11.2.15-28............................ Amendment 2 11.2.15-29................................. Revision 4 11.2.15-30 thru 11.2.15-31....... Revision 3 11.2.15-32................................. Revision 4 11.2.15-33 thru 11.2.15-35.. Amendment 2 11.2.16-1.............................. Revision 19A 11.2.16-2 thru 11.2.16-9........... Revision 8 11.2.16-lOthru 11.2.16-17.. Revision 19A 11.3-1........................................ Revision 3 11.3-2 thru 11.3-3..................... Revision 0 11.3-4........................................ Revision 3 11.3-5................................... Revision 19A Chapter 12 12-i thru 12-ii....................... Amendment 1 12-1........................................... Revision 5 12-2 thru 12-3........................... Revision 8 12-4...................................... Revision 19A 12A-I thru 12A-2...................... Revision 3 12B-1 thru12B-2....................... Revision 3 l 2C-1......................................... Revision 0 12C-2......................................... Revision 8 12C 1-1....................................... Revision 3 l 2C2-l....................................... Revision 8 I 2C2-2....................................... Revision 3
FSAR - UMS Universal Storage System Docket No. 72-1015 List of Effective Pages (continued) l 2C3-l thru l 2C3-8.................. Revision 0 l 2C3-9 thru l 2C3-28................ Revision 8 12C3-29 thru l 2C3-30............ Revision 13 l 2C3-3 l................................... Revision 14 l 2C3-32 thru l 2C3-34.............. Revision 8 12C3-35 thru 12C3-37............ Revision 13 12C3-38 thru 12C3-40.............. Revision 8 Chapter 13 13-i thru 13-ii............................ Revision 0 13.1-1 thru 13.2-7..................... Revision 0 13.2-8........................................ Revision 3 13.3-1...................................... Revision 10 8
April 2020 Revision 20B
- FSAR-UMS Universal Storage System Docket No. 72-1015 1.8 License Drawings December 2019 Revision 19A This section presents the list of License Drawings for the Universal Storage System.
1.8.1 License Drawings for the UMS Universal Storage System Drawing Revision No. of Number Title No.
Sheets 790-501 Canister/Basket Assembly Table, NAC-UMS 3
1 790-559 Assembly, Transfer Adapter, NAC-UMS 7
4 790-560 Assembly, Standard Transfer Cask (TFR), NAC-UMS 17 7
790-561 Weldment, Structure, Vertical Concrete Cask (VCC),
16 4
NAC-UMS 790-562 Reinforcing Bar and Concrete Placement, Vertical Concrete 20 8
Cask (VCC), NAC-UMS 790-563 Lid, Vertical Concrete Cask (VCC), NAC-UMS 6
1 790-564 Shield Plug, Vertical Concrete Cask (VCC), NAC-UMS 8
3 790-565 Nameplate, Vertical Concrete Cask (VCC), NAC-UMS 5
1 790-570 Fuel Basket Assembly, 56 Element BWR, NAC-UMS 6
3 790-571 Bottom Weldment, Fuel Basket, 56 Element BWR, 3
1 NAC-UMS 790-572 Top Weldment, Fuel Basket, 56 Element BWR, NAC-UMS 4
1 790-573 Support Disk and Misc. Basket Details, 56 Element BWR, 8
1 NAC-UMS 790-574 Heat Transfer Disk, Fuel Basket, 56 Element BWR, 3
1 NAC-UMS 790-575 BWR Fuel Tube, NAC-UMS 11 2
790-581 PWR Fuel Tube, NAC-UMS 9
2 790-582 Shell Weldment, Canister, NAC-UMS 13 2
790-583 Assembly, Drain Tube, Canister, NAC-UMS 9
1 790-584 Details, Canister, NAC-UMS 20 3
790-585 Transportable Storage Canister (TSC), NAC-UMS 25 3
790-587 Spacer Shim, Canister, NAC-UMS 1
1 790-590 Loaded Vertical Concrete Cask (VCC), NAC-UMS 9
2 790-591 Bottom Weldment, Fuel Basket, 24 Element PWR, 6
2 NAC-UMS 1.8-1
FSAR - UMS Universal Storage System Docket No. 72-1015 License Drawings ( continued)
Drawing Number Title 790-592 Top Weldment, Fuel Basket, 24 Element PWR, NAC-UMS 790-593 Support Disk and Misc. Basket Details, 24 Element PWR, NAC-UMS 790-594 Heat Transfer Disk, Fuel Basket, 24 Element PWR, NAC-UMS 790-595 Fuel Basket Assembly, 24 Element PWR, NAC-UMS 790-601 Damaged Fuel Can (DFC), BWR, NAC-UMS 790-605 BWR Fuel Tube, Over-Sized Fuel, NAC-UMS 790-613 Supplemental Shielding, VCC Inlets, NAC-UMS 790-617 Door Stop, NAC-UMS 790-671 Bottom Weldment, Fuel Basket, 56 Element BWR DF, NAC-UMS70-672 Top Weldment, Fuel Basket, 56 Element BWR DF, NAC-UMS
- Proprietary Drawing Removed 1.8.3 Site Specific Spent Fuel License Drawings Drawing Number Title 412-501 S ent Fuel Can Assembl, Maine Yankee MY, NAC-UMS 412-502 Fuel Can Details, Maine Yankee MY, NAC-UMS 1.8-2 April 2020 Revision 20B Revision No. of No.
Sheets 8
I 7
2 2
1 10 2
lNP*
1 12 2
2 1
4 2
1 1
1 1
Revision No. of No.
Sheets 4
2 6
6
8 F
E D
C 8
A NOTES:
8 7
6 7
6 5
PROPRIETARY INFORMATION REMOVED
© 5
4 4
3 98 99 ITEM NAME ASSY ASSV
,__~U~N~LE~S~S~O~T~H~E~R~W'-""IS~E~S~T~A~T~E~D~ GROUP OIMENSIONINGANO TOL[RANCINC SHALL BE FER ASME v1.-.5"t.9"1, ALL lHREAO DEPTH CAtl"oUTS ARE TO RE CONSIDERED AS A a.ON DEPTH OF Pi:RHCT ?READS A!.L OIM[N:i\\ONS ARE lo'II INCHES MACHINED SURFACES SKAll.. SE t/DR BEfTEJ!.
IIIEXTASSEMBLV 790-585 LICENSE 3
PREPARER CHECKER PROJECT MANAGER LICENSING QUALITY MATERIAL NAME 2
.DATE REV CHANGE ONP INITIAL ISSUE - OCR A
!NP INC DCR ONPA ORAWlNG No; DESCRIPTION ANAC
~I INTERNA T/ONAL DAMAGED FUEL CAN (DFC)
BWR, NAC - UMS 790 DRAWING 601 REV 1NP SH I
OF 1 3/19/2020 F
E D
C 8
A
FSAR - UMS Universal Storage System Docket No. 72-1015 FS =~= 63' 300 = 38.2 > 10 CY 1659 max DFC tube body welds evaluation December 2019 Revision 19A The welds joining the tube body to the flange and bottom assembly are full penetration welds (ASME,Section III, Subsection NG, Type III, paragraph NG-3352.3). Per Subsection NG, Table NG-3352-1, the weld quality factor (n) for a Type III weld with visual surface inspection is 0.5.
The weld stress (crw) is:
where:
CY =1.l(P)=l.1(809)=811 si A
1.097 p
P
= the combined weight of the tube body, the neutron absorber weight, bottom assembly, the cladding weight, and can contents; 62 + 26 + 7 + 12 + 702 = 809 lb.
A =
cross sectional area of thinner member joined= 1.097 in2 The factors of safety on material yield strength (FSy) and ultimate strength (FSu) of Type 304 Stainless Steel at 600°F are:
FS = n*Sy = 0.5(18,600) = l 1.5 > 6 CYW 811 FS = n*S11 = 0.5(63,300) = 39_0 > lO CY""
811 Therefore, the criteria ofNUREG-0612 and ANSI N14.6 for the lifting of non-redundant systems are satisfied.
DFC tube body tensile stress evaluation The tube body will be subjected to tensile loads during lifting operations. The load (P) includes the can contents (702 lb design weight), the tube body weight (62 lb), the neutron absorber weight 3.9-11
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B (26 lb), the cladding weight (12 lb) and the bottom assembly weight (7 lb) for a total of 809 lb. A load of 809 lb with a 10% dynamic load factor is used for the analysis.
The tensile stress ( cr1) is then:
where:
A= 6.142 - 6.052 = 1.097 in2 The margin of safety (MS) based on allowable for primary membrane (tensile) stress (Sm) for Type 304 Stainless Steel at 600°F is:M MS= 1.0 Sm/cr1-l = 16,700/811-1 =+ 19.6 Bottom Plate Evaluation The DFC bottom plate is evaluated for the lift condition using ASME Boiler and Pressure Vessel Code,Section III, Subsection NG [6]. Since the DFC lifting operations always occur underwater, material properties are evaluated at 200°F.
Bending Stress The controlling stress in the DFC bottom plate is the bending stress occurring in the 0.17-inch thick disk located in the middle of the bottom plate. Case No. 17 in Table 24 ofRoark's Formulas for Stress and Strain [26] provides the expression for the moment for a uniform load over a circular area at the center of a uniform thick disk with fixed boundary conditions around its perimeter. This is applicable for the evaluation of the 0.17-inch thick disk located in the middle of the bottom plate. Therefore, the maximum bending moment occurring at the center of the bottom plate disk (Mmax,c) is calculated:
WxDLF (a)
M,nax.c=
x(l+v)xln--, =171in-lb 4rr r 0 where:
W = 702 lb, weight ofBWR fuel assembly DLF= 1.1, dynamic load factor (10%)
3.9-12
FSAR - UMS Universal Storage System Docket No. 72-1015 v = 0.31, Poisson's Ratio a =
2
- 5 = 1.25 in, radius of 0.17" thick disk 2
r'o = r0 = 0.15 in, because ro > 0.5t ro =do= 0.15 in, radius of the applied load 2
do= 0.3 in, bearing area diameter of the applied load t = 0.17 in, thickness of the middle disk April 2020 Revision 20B The maximum bending moment that occurs around the outer radius (1.25-inch) of the 0.17-inch thick disk (M,nax.r) is calculated:
WxDLF M,nax.r =
= 61 m-lb 4rr The maximum bending moment at the center of the disk is greater than that at the outer radius; therefore, the maximum disk bending moment (in units of kip-inch) corresponds to the center of the disk.
M, Mmax,c O 171 k" max=
=.
1p-1n 1000 The maximum bending stress (O"max) at the center of the disk is calculated:
O"max = 6 X M~ax = 35.4 ksi t
The margin of safety for the maximum bending stress of the disk is calculated as follows. Note that the allowable membrane plus bending stress is l.5Sm.
1.SSm MS=-- -I= +0.4 CJ'max where:
Sm= 33.1 ksi, design stress intensity of SA-240 Type XM-19 at 200°F Bearing Stress The bearing stress (O"bearing) from the BWR fuel assembly on the DFC bottom plate is calculated:
WXDLF O"bearing =
2 = 10.9 ksi rrxr0 where:
W = 702 lb, weight ofBWR fuel assembly 3.9-13
FSAR - UMS Universal Storage System Docket No. 72-1015 DLF = 1.1, dynamic load factor (10%)
ro = do = 0.15 in, radius of the applied load 2
do= 0.3 in, bearing area diameter of the applied load (s~e Figure 5.4)
April 2020 Revision 20B The margin of safety (MS) for bearing stress is calculated based on the allowable bearing stress of Sy.
Sy MS= ~~-1= +3.3
<lbearing where:
Sy= 47.1 ksi, yield strength of SA-240 Type XM-19 at 200°F 3.9.2.3 BWR Damaged Fuel Can Tube Body-Side Impact The governing side impact condition corresponding to the hypothetical cask tip-over accident is evaluated in this section. The majority of the BWR damaged fuel can (DFC) tube body is contained in the basket assembly. Because both the tube body and the support disks of the basket have square cross sections, they will be in full contact (for 158.83 inches longitudinally) during the side impact and no significant bending stress will be introduced into the support disk. The last 19.63 inches (tube body and top flange) will be unsupported past the support disk in the side impact configuration.
The tube body will be evaluated as a cantilevered beam with the combined weight (P) of the overhanging tube body, top flange, and lid assembly multiplied by the appropriate acceleration factor and, conservatively, concentrated at the top end of the top flange.
3.9-14
FSAR - UMS Universal Storage System Docket No. 72-1015 April 2020 Revision 20B top flange p
/"".::" support disk I~
~
(Unit: inch)
The maximum bending stress (fb) is determined as follows.
where:
!' = M maxc = 11,778(3.07) = 5 322 si 1 b I
- 6. 793 p
Mmax =
P x a XL= 20(30)(19.63) = 11,778 lb-in a =
30g P
20 lb; (lid plate, 2 lb+ lid wall, 2 lb+ top flange, 2 lb+ tube body (62 lb x 19.13/177.57 in/in= 6.68 lb)+ cladding (12 lb x 19.13/177.1 in/in= 1.3 lb)
+ neutron absorber (26 lb x 19.13/176.3 in/in= 2.82 lb), which is equal to 16.8 lb; use 20 lb bounding)
L =
19.63 in (total overhang length of the tube body and top flange)
C =
6.14/2 = 3.07 in I =
bh 3 -b.h 3
6 144 6 05 4
-' =
= 6.793 in4 12 12 The shear stress ('c) is:
r =Pg= 20(3o) = 547 psi A
1.097 3.9-15
FSAR - UMS Universal Storage System Docket No. 72-1015 where:
A= 6.142-6.052 = 1.097 in2 April 2020 Revision 20B O"i,0"2 =_!_~ +/-~ii; +4r 2 )=_!_(5,322+/-~5,32i +4(547) 2 )=5,378. psi and-56 psi 2
2 The stress intensity (crmax) = Jcr1 - cr2J = 5,434 psi The margin of safety (MS) is:
MS= 1.0 Su l = 1.0(63,300) _ 1 = +l0.6 O"max 5,434 3.9.2.4 BWR Damaged Fuel Can Tube Body-End Impact The DFC is evaluated for a bottom end impaction corresponding to the cask 24-inch drop accident in this section. For the bottom end drop, the top flange, the lid assembly (Lid plate+ Lid wall),
neutron absorber, cladding and the tube body act against the bottom assembly (Bottom plate weldment + Collar + Bottom lid). The total weight is conservatively used for tube body compression.
DFC tube body compressive stress evaluation For the end impact accident conditions, the tube is evaluated for a 60g acceleration.
The compressive load (P) on the tube is the combined weight of the lid assembly, top flange, and tube body times 60g:
The compressive load (P) is:
p = J J3lb X 60g = 6,780 lb; The compressive stress (Sc) in the tube body is:
S = p = 6'780 lb = 6 180 si c
A l.097 in.2 p
The margin of safety (MS) is then:
MS= 0.7 S,, _ 1 = 0.7(63,300) psi 1 = +6.2 for accident conditions at 600°F.
Sc 6,180 psi 3.9-16
FSAR - UMS Universal Storage System Docket No. 72-1015 DFC tube body buckling evaluation April 2020 Revision 20B The tube is evaluated, using the Euler formula, to determine the critical buckling load (Per):
where:
E = 25.2 x 106 psi 4
4 I
= 6.14 -6.05 = 6_793 in.4 12 Le = 2L (worst case condition)
L = tube body length (177.57 in)
Because the maximum compressive load (6,780 lb under the accident condition) is much Jess than the worst-case critical buckling load (13,396 lb) and the support disks also provide lateral constrains to the body tube, the tube has adequate resistance to buckling.
3.9-17