Similar Documents at Salem |
---|
Category:Exemption from NRC Requirements
MONTHYEARML24009A1022024-01-26026 January 2024 Exemption from Select Requirements of 10 CF Part 73 (EPID L-2023-LLE-0045 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) LR-N23-0073, Request for Exemption from Specific Requirements in New 2023 Security Rule2023-11-17017 November 2023 Request for Exemption from Specific Requirements in New 2023 Security Rule ML22034A9832022-02-15015 February 2022 FRN - Notice of Issuance of COVID-19 Exemptions Issued in January 2022 ML22005A3232022-01-0707 January 2022 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Exemption from Select Requirements of 10 CFR Part 26 (EPID L-2022-LLE-0000 (COVID-19)) LR-N22-0007, Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs2022-01-0505 January 2022 Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs ML21056A5422021-03-0303 March 2021 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Exemption from Select Requirements of 10 CFR Part 26 LR-N21-0020, Subsequent Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs2021-02-25025 February 2021 Subsequent Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs ML20358A2812020-12-28028 December 2020 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Exemption from Select Requirements of 10 CFR Part 26 (EPID L-2020-LLE-0239 (COVID-19)) LR-N20-0085, Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs2020-12-23023 December 2020 Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs ML20335A0902020-12-21021 December 2020 Federal Register Notice - November 2020 COVID-19 Exemptions ML20315A4342020-12-0707 December 2020 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Temporary Exemption from the Exercise Requirements of 10 CFR Part 50, Appendix E, Sections IV.F.2.B and IV.F.2.C (EPID L-2020-LLE-0164 (COVID-19)) ML20309A8872020-11-20020 November 2020 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - One-Time Exemption from Certain Requirements of 10 CFR Part 73, Appendix B, General Criteria for Security Personnel, Section VI (EPID L-2020-LLE-0168 (COVID-19)) LR-N20-0070, Request for a One-Time Exemption from 10 CFR 73, Appendix B, Section VI, Subsection C.3.(I)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to COVID-19 Pandemic2020-10-26026 October 2020 Request for a One-Time Exemption from 10 CFR 73, Appendix B, Section VI, Subsection C.3.(I)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to COVID-19 Pandemic LR-N20-0066, Exemption Request from 10 CFR 50 Appendix E, Biennial Emergency Preparedness Exercise Requirements Due to COVID-19 Pandemic2020-10-13013 October 2020 Exemption Request from 10 CFR 50 Appendix E, Biennial Emergency Preparedness Exercise Requirements Due to COVID-19 Pandemic ML20243A0002020-09-23023 September 2020 FRN - Notice of Issuance of Multiple Exemptions Regarding Various Parts of 10 CFR Due to COVID-19 Impacts for August 2020 ML20204A9372020-08-0303 August 2020 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Exemptions from Certain Requirements of 10 CFR Part 73, Appendix B, General Criteria for Security Personnel, Section VI (EPID L-2020-LLE-0118 (Covid 19)) LR-N20-0049, LR-N20-0049 COVID-19 Email Exemption Request Security FOF - NRC for Salem Generating Station, Units 1 & 2 and Hope Creek Generating Station2020-07-21021 July 2020 LR-N20-0049 COVID-19 Email Exemption Request Security FOF - NRC for Salem Generating Station, Units 1 & 2 and Hope Creek Generating Station ML20148M3292020-05-29029 May 2020 Unit Nos. 1 and 2 - Exemption from Select Requirements of 10 CFR Part 55, Operators' Licenses (EPID L-2020-LLE-0065 (COVID-19)) ML20142A5132020-05-21021 May 2020 Part 55 Exemption Request for Power Reactors (COVID-19) (Redacted) ML20134J0832020-05-19019 May 2020 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Exemptions from Certain Requirements of 10 CFR Part 73, Appendix B, General Criteria for Security Personnel, Section VI ML20122A1402020-05-0707 May 2020 Exemption from Select Requirements of 10 CFR Part 55, Operators' Licenses (EPID L-2020-LLE-0048 (COVID-19)) ML20126G3782020-05-0404 May 2020 Part 55 Exemption Request (COVID-19)(Redacted) ML12299A0812012-10-26026 October 2012 and Salem Nuclear Generating Station, Units 1 and 2 - Exemption from Certain Requirements of 10 CFR Part 26, Fitness for Duty Programs NRC-2012-0264, Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2 - Exemption from Certain Requirements of 10 CFR Part 26, Fitness for Duty Programs (TAC Nos. ME7651, ME7652 and ME7653)2012-10-26026 October 2012 Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2 - Exemption from Certain Requirements of 10 CFR Part 26, Fitness for Duty Programs (TAC Nos. ME7651, ME7652 and ME7653) ML12299A0712012-10-26026 October 2012 and Salem Nuclear Generating Station, Units 1 and 2 - Exemption from Certain Requirements of 10 CFR Part 26, Fitness for Duty Programs NRC-2010-0043, Hope Creek Generating Station and Salem Nuclear Generating Station, Unit Nos. 1 and 2 Docket Nos. 50-272, 50-311 and 50-354 Exemption2010-02-25025 February 2010 Hope Creek Generating Station and Salem Nuclear Generating Station, Unit Nos. 1 and 2 Docket Nos. 50-272, 50-311 and 50-354 Exemption ML1001203242010-02-25025 February 2010 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 Docket Nos. 50-272, 50-311 and 50-354 Exemption LR-N08-0032, Request for Exemption from 10 CFR 50.82(a)(8)(i) and (Ii), NRC Regulations to Permit the Immediate Withdrawal of Certain Funds from Nuclear Decommissioning Trust Funds2008-04-0707 April 2008 Request for Exemption from 10 CFR 50.82(a)(8)(i) and (Ii), NRC Regulations to Permit the Immediate Withdrawal of Certain Funds from Nuclear Decommissioning Trust Funds ML0317407692003-06-24024 June 2003 Exemption, Exemption from Requirements of 10 CFR Part 50, Appedix R, Sections III.G.3 & III.L.3, for Fire Areas 1(2)-FA-AB-64B, 1(2)-FA--AB-84B, and 1(2)-FA-AB-84C ML0300902912003-01-0909 January 2003 Request for Exemption from 10 CFR 55.59 2024-01-26
[Table view] Category:Letter
MONTHYEARIR 05000272/20230042024-02-0505 February 2024 Integrated Inspection Report 05000272/2023004 and 05000311/2023004 ML24009A1022024-01-26026 January 2024 Exemption from Select Requirements of 10 CF Part 73 (EPID L-2023-LLE-0045 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) IR 05000272/20234012024-01-22022 January 2024 Material Control and Accounting Program Inspection Report 05000272/2023401 and 05000311/2023401 ML24004A1542024-01-0808 January 2024 Notification of Conduct of a Fire Protection Team Inspection LR-N23-0079, Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days2023-12-0707 December 2023 Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days ML23270C0072023-11-29029 November 2023 Notice of Proposed Amendment to Decommissioning Trust Agreement LR-N23-0077, Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion2023-11-29029 November 2023 Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion ML23324A3072023-11-17017 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000272/20230032023-11-13013 November 2023 Integrated Inspection Report 05000272/2023003 and 05000311/2023003 LR-N23-0072, Core Operating Limits Report Cycle 302023-11-0101 November 2023 Core Operating Limits Report Cycle 30 IR 05000272/20230102023-10-12012 October 2023 Biennial Problem Identification and Resolution Inspection Report O5000272/2023010 and 05000311/2023010 IR 05000272/20234022023-10-12012 October 2023 and Salem Nuclear Generating Station, Units 1 and 2 - Security Baseline Inspection Report 05000354/2023402, 05000272/2023402 and 05000311/2023402 (Cover Letter Only) LR-N23-0045, and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement2023-09-0808 September 2023 and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement ML23249A2612023-09-0606 September 2023 License Amendment Request to Modify the Salem and Hope Creek Exclusion Area Boundary IR 05000272/20230052023-08-31031 August 2023 Updated Inspection Plan for Salem Nuclear Generating Station, Units 1 and 2 (Reports 05000272/2023005 and 05000311/2023005) ML23233A0762023-08-21021 August 2023 Requalification Program Inspection ML23192A8212023-08-14014 August 2023 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Issuance of Amendment Nos. 234, 347, and 329 Revise Technical Specifications to Delete Meteorological Tower Location IR 05000272/20230022023-08-0909 August 2023 Integrated Inspection Report 05000272/2023002 and 05000311/2023002 LR-N23-0055, Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days2023-08-0303 August 2023 Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days IR 05000354/20230022023-08-0303 August 2023 Integrated Inspection Report 05000354/2023002 and Independent Spent Fuel Storage Installation Inspection Report 07200048/2023001 LR-N23-0054, In-Service Inspection Activities2023-07-26026 July 2023 In-Service Inspection Activities LR-N23-0046, Emergency Plan Document Revisions Implemented June 28, 20232023-07-10010 July 2023 Emergency Plan Document Revisions Implemented June 28, 2023 LR-N23-0005, License Amendment Request to Amend Technical Specifications (TS) 6.8.4.f for Permanent Extension of Type a and Type C Leak Rate Test Frequencies2023-06-23023 June 2023 License Amendment Request to Amend Technical Specifications (TS) 6.8.4.f for Permanent Extension of Type a and Type C Leak Rate Test Frequencies ML23139A1472023-06-0505 June 2023 Relief Request Associated with Fourth Interval In-service Inspection Limited Examinations of Weld Coverage ML23096A1842023-05-0909 May 2023 Issuance of Amendment No. 328 Revise and Relocate Reactor Coolant System Pressure and Temperature Limits and Pressurizer Overpressure Protection System Limits to Pressure and Temperature Limits Report IR 05000272/20230012023-05-0303 May 2023 Integrated Inspection Report 05000272/2023001 and 05000311/2023001 ML23081A4662023-05-0202 May 2023 Issuance of Amendment Nos. 346 and 327 Revise Technical Specifications to Extend Allowable Outage Time for Inoperable Emergency Diesel Generator IR 05000272/20233012023-05-0101 May 2023 Initial Operator Licensing Examination Report 05000272/2023301 and 05000311/2023301 LR-N23-0034, 2022 Annual Radiological Environmental Operating Report (AREOR) - Salem Nuclear Generating Station, Unit Nos. 1 and 2 and Hope Creek Generating Station2023-04-27027 April 2023 2022 Annual Radiological Environmental Operating Report (AREOR) - Salem Nuclear Generating Station, Unit Nos. 1 and 2 and Hope Creek Generating Station LR-N23-0035, 2022 Annual Radioactive Effluent Release Report (ARERR)2023-04-27027 April 2023 2022 Annual Radioactive Effluent Release Report (ARERR) LR-N23-0033, Core Operating Limits Report Cycle 272023-04-26026 April 2023 Core Operating Limits Report Cycle 27 LR-N23-0010, License Amendment Request Revision of Technical Specification (TS) to Delete TS Section 5.5 - Meteorological Tower Location2023-04-21021 April 2023 License Amendment Request Revision of Technical Specification (TS) to Delete TS Section 5.5 - Meteorological Tower Location ML23089A0942023-04-17017 April 2023 NRC to PSEG Hope Creek, Transmittal of the National Marine Fisheries Service'S March 24, 2023, Biological Opinion GAR-2020-02842 Concerning Salem and Hope Creek ML23087A1492023-04-17017 April 2023 NRC to PSEG Salem, Transmittal of the National Marine Fisheries Service'S March 24, 2023, Biological Opinion GAR-2020-02842 Concerning Salem and Hope Creek ML23103A3232023-04-13013 April 2023 Submittal of Updated Final Safety Analysis Report, Rev. 26, Summary of Revised Regulatory Commitments for Hope Creek, Summary of Changes to PSEG Nuclear LLC, Quality Assurance Topical Report, NO-AA-10, Rev. 89 ML23095A3682023-04-12012 April 2023 and Salem Nuclear Generating Station, Unit Nos. 1 and 2 - Threshold Determination for Proposed Transfer of Land Ownership LR-N23-0006, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-24024 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations ML23086A0912023-03-24024 March 2023 NMFS to NRC, Transmittal of Biological Opinion for Continued Operations of Salem and Hope Creek Nuclear Generating Stations RS-23-049, Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-23023 March 2023 Constellation Energy Generation, LLC, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations LR-N23-0019, and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums2023-03-21021 March 2023 and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums ML23044A1052023-03-13013 March 2023 Issuance of Amendment Nos. 345 and 326 Relocate Technical Specifications Requirements for Reactor Head Vents to Technical Requirements Manual ML23037A9712023-03-0909 March 2023 and Salem Nuclear, Unit Nos. 1 and 2 Issuance of Amendment Nos. 233, 344, and 325 Relocate Technical Specification Staff Qualification Requirements to the PSEG Quality Assurance Topical Report IR 05000272/20230112023-03-0707 March 2023 Comprehensive Engineering Team Inspection Report 05000272/2023011 and 05000311/2023011 IR 05000272/20220062023-03-0101 March 2023 Annual Assessment Letter for Salem Nuclear Generating Station, Units 1 and 2 (Reports 05000272/2022006 and 05000311/2022006) LR-N23-0016, and Salem Generating Station, Units 1 and 2 - Report of Changes, Tests, and Experiments2023-02-28028 February 2023 and Salem Generating Station, Units 1 and 2 - Report of Changes, Tests, and Experiments LR-N23-0012, Annual Property Insurance Status Report2023-02-24024 February 2023 Annual Property Insurance Status Report LR-N23-0014, Stations Submittal of 2022 Annual Report of Fitness for Duty Performance Data Per 10 CFR 26.203(e) and 10 CFR 26.7172023-02-23023 February 2023 Stations Submittal of 2022 Annual Report of Fitness for Duty Performance Data Per 10 CFR 26.203(e) and 10 CFR 26.717 ML23034A1532023-02-0909 February 2023 Operator Licensing Examination Approval ML23019A3482023-02-0202 February 2023 Issuance of Relief Request No. SC-I5R-221 for the Alternative Repair for Service Water System Piping LR-N23-0003, Response to Requests for Additional Information Salem Unit 2 Relief Request S2-I4R-2112023-02-0101 February 2023 Response to Requests for Additional Information Salem Unit 2 Relief Request S2-I4R-211 2024-02-05
[Table view] |
Text
May 7, 2020 Mr. Eric Carr President and Chief Nuclear Officer PSEG Nuclear LLC - N09 P.O. Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 -
EXEMPTION FROM SELECT REQUIREMENTS OF 10 CFR PART 55, OPERATORS LICENSES (EPID L-2020-LLE-0048 [COVID-19])
Dear Mr. Carr:
The U.S. Nuclear Regulatory Commission (NRC) has approved the requested exemption from specific requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 55, Operators Licenses, for licensed operators at the Salem Nuclear Generating Station, Unit Nos. 1 and 2. This action is in response to the PSEG Nuclear LLC (facility licensee) application dated May 4, 2020 (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML20126G378), related to an NRC letter dated April 14, 2020 (ADAMS Accession No. ML20104C071), describing a process to request expedited review of certain exemptions from 10 CFR Part 55 during the COVID-19 Public Health Emergency (PHE).
Specifically, the application requested exemption from medical examination requirements in 10 CFR 55.21 and 10 CFR 55.53(i) and provided the following information:
The names and docket numbers of the licensed operators for whom the exemption is being requested.
A description of the interim compensatory measures that the facility licensee is using to address delay in receipt of recommendations from a licensed physician concerning the licensed operators health.
Consistent with 10 CFR 55.11, Specific exemptions, the NRC may, upon application by an interested person, or upon its own initiative, grant such exemptions from the requirements of the regulations in 10 CFR Part 55 as it determines are authorized by law and will not endanger life or property and are otherwise in the public interest.
Sections 55.21 and 55.53(i) of 10 CFR require a medical examination of each licensed operator every 2 years by a licensed physician who uses the applicable ANSI/ANS standard. Based on this examination, the physician certifies whether the licensed operator has been found to meet the medical requirements of 10 CFR 55.33(a)(1) and whether the licensed operators license should be conditioned based on an identified health problem. Consistent with 10 CFR 55.25, the facility licensee must notify the NRC if it learns that the licensed operator has developed a permanent condition that causes the licensed operator to fail to meet the health requirements. If the facility licensee alerts the NRC to a health concern, then the NRC uses a qualified medical
E. Carr expert to review the relevant medical information. Neither the facility licensee nor the NRC makes medical judgments of licensed operators.
A PHE requiring the use of social distancing and other practices intended to slow the spread of illness and the potential long-term unavailability of routine medical appointments due to a PHE were not considered during the rulemaking that established the medical examination requirements.
During the COVID-19 PHE, licensed operators might not be able to receive the required biennial medical examination from a licensed physician. The compensatory measure that the facility licensee (in coordination with the licensed operators) will implement during the exemption term will provide the results of a partial medical examination to the facility licensee, which will consider the recommendations as to whether the ANSI/ANS 3.4 standard appears to be met based on available information. Consistent with 10 CFR 55.25, the facility licensee must continue to notify the NRC of permanent conditions that cause licensed operators to fail to meet the health requirements.
Existing administrative controls for human performance error prevention, such as peer-checking, will help ensure the continued safe operation of the facility. Additionally, the requirements of 10 CFR 26.33, Behavioral observation, and 10 CFR 26.31, Drug and alcohol testing, remain in effect during the exemption term. These requirements continue to provide reasonable assurance that, should a licensed operator become unfit for duty, the impairment will be detected and addressed. Also, if an unknown (due to a partial medical examination) medical condition is causing symptoms (e.g., fatigue), these programs may provide the basis for a facility licensee to remove a licensed operator from shift. Based on the proposed compensatory measure and the continued compliance with existing administrative controls and the regulatory requirements in 10 CFR 55.25, 10 CFR 26.33, and 10 CFR 26.31, the NRC staff finds that the requested exemption will not endanger life or property.
The requested exemption from the biennial medical examination requirements addresses the fact that a licensed operator may not be able to obtain this examination during the COVID-19 PHE because of a limited availability of medical resources and the possibility that an in-office medical examination may expose the operator to COVID-19. The requested exemption ensures that licensed operators are not required to take actions that would conflict with practices recommended by the Centers for Disease Control and Prevention to limit the spread of COVID-19.1 Therefore, the NRC staff finds that the requested exemption is in the public interest.
The NRC staff determined that exemption from the medical examination requirements is permissible under the Atomic Energy Act of 1954, as amended, and other regulatory requirements. Therefore, the NRC staff finds that the requested exemption is authorized by law.
NRC approval of this exemption request is categorically excluded under 10 CFR 51.22(c)(25) and there are no extraordinary circumstances present that would preclude reliance on this exclusion. The NRC staff determined, per 10 CFR 51.22(c)(25)(vi)(E), that the requirements from which the exemption is sought involve education, training, experience, qualification, requalification, or other employment suitability requirements. The NRC staff also determined that approval of this exemption involves no significant hazards consideration because it does 1
Centers for Disease Control and Prevention, How to Protect Yourself and Others, April 18, 2020 (ADAMS Accession No. ML20125A069).
E. Carr not authorize any physical changes to the facility or any of its safety systems, nor does it change any of the assumptions or limits used in the facility licensees safety analyses or introduce any new failure modes; no significant change in the types or significant increase in the amounts of any effluents that may be released offsite because this exemption does not affect any effluent release limits as provided in the facility licensees technical specifications or by the regulations in 10 CFR Part 20, Standards for Protection Against Radiation; no significant increase in individual or cumulative public or occupational radiation exposure because this exemption does not affect limits on the release of any radioactive material or the limits provided in 10 CFR Part 20 for radiation exposure to workers or members of the public; no significant construction impact because this exemption does not involve any changes to a construction permit; and no significant increase in the potential for or consequences from radiological accidents because this exemption does not alter any of the assumptions or limits in the facility licensees safety analysis. In addition, the NRC staff determined that there would be no significant impacts to biota, water resources, historic properties, cultural resources, or socioeconomic conditions in the region. As such, there are no extraordinary circumstances present that would preclude reliance on this categorical exclusion. Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the approval of this requested exemption.
Based on the above, the NRC staff finds that (1) the exemption is authorized by law, (2) the exemption will not endanger life or property, and (3) the exemption is otherwise in the public interest.
This exemption is effective upon issuance until 90 days after the COVID-19 PHE is ended or until December 31, 2020, whichever occurs first.
Sincerely, Craig G. Digitally signed by Craig G. Erlanger Erlanger Date: 2020.05.07 18:45:42 -04'00' Craig G. Erlanger, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311 cc: Listserv
ML20122A140 *via e-mail OFFICE NRR/DORL/PL1/PM NRR/DORL/LPL1/LA NRR/DORL/LPL1/BC NRR/DRO/IOLB/BC*
NAME JKim LRonewicz JDanna CCowdrey DATE 05/05/2020 05/05/2020 05/05/2020 05/05/2020 OFFICE OGC (NLO)* NRR/DORL/D NAME JWachutka CErlanger DATE 05/07/2020 05/07/2020