NPDES Discharge Monitoring Rept for Jul 1992 for Hope Creek Generating Station
ML20118A368
Person / Time
Site: Hope Creek 
Issue date: 07/31/1992
From: Hagan J
Public Service Enterprise Group
To: Corporale G
NEW JERSEY, STATE OF
References
NUDOCS 9209020005
Download: ML20118A368 (23)


Text

,

c p:

7

.O PSEG1 1

_ Public Service Electric and Gas Cornpany P.OI Box 236 Hancocks Bridge. New Jersey 08038 Hope Creek Generating Station August 25, 1992 ChiefLGeorge Corporale Bureau of Information Systems P. O.-: Box CN-029 Trenton, N. J.

08625 ret ~ NEW JERSEY POLLUTANT DISCHARGE

-ELIMINATION SYSTEM

' DISCHARGE-MONITORING REPORT HOPE CREEK GENERATING STATION NJPDES= PERMIT NJ0025411 4

Dear Sir:

-Attached'is the Discharge Monitoring Report for the Hope Creek-Generating Station.for the month ot July 1992.

'This report is required by and prepared-specifically for the-Environmental Protection Agency-(EPA) and the New Jersey Department of Environmental Protection (NJDEP)'. It presents only-the observed results-of measurements and analysis required to be performed-by.the above agencies. The choice of the-measurement devices and analytical methods are1 controlled

.by the EPArand the NJDEP, not by the company, and-there are

limitations on-the accuracy of such measurement devices'and analytical techniques even-when used and maintained as required. Accordingly, this report-is not intended as an

. assertion?that-'any instrument has: measured',- or that any reading-analytical result represents the true value with absolute accuracy,;nor isLit an endorsement of'the suitabilityfof-any analytical or measurement procedure.

-If_you-have any questions concerning thisireport,-please-lael free-to contact Mr.-.C..E. Whit 9.

Sincer ly,

=

J ep Hag n-Genera ager -

Hope Creek Operations

~.

01003!i 1625 LThe Energy People.

/

t.

- /f 9209020005 920731

-: w PDR-ADOCK-05000354 R.

.PDR

l NJPDES 2

8/25/92 i,

fCW:eaj Attachments C

Executive Director, DRBC USEPA - Dr. Richard Baker USNRC

+

l l

1 l-.

l-l

NJPDES 8/25/92-Explanation.of conditions July 1992 The following explanations are included to clarify possible deviation from permit conditions.

General.- The columns labeled "No. Ex", on the enclosed DMR, tabulate the number of daily discharge values outside the indicated limits.

Data reporting and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.

Analytical values performed by the following NJDEP certified laboratories:

NET Atlantic, Inc.

08153)

Hope Creek Generatin(g Station (17451)

Talbot Laboratory 1ng,c.

In (77535)

South' Jersey Test

-Inc. (06431)

Deviations from required sampling, analysis monitoring and reporting methods and periodicities are noted on the respective DMR.

Frequency for discharge point 461A, the Cooling Tower Blowdown, and the River were done.at approximately 5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> intervals to provide for the cycles of concentration in the system.

As per'the Administrative Consent order the TSS limit for discharge points'462A, A63A and 464 have been lifted and the interim thermal limits for discharge point 461A have been changed to 443 MBTU/hr-(June - September) and 731 MBTU/hr (October May).-

Results reported on the Discharge Monitoring Pe, ort forms are-consistent with permit limits, data supplied f.sm contract

-laboratories, the June 1991 revision of the N7DEP DMR Instruction manual and specific guidance from DEP personnel attending DMR outreach seminars.

Guidance from the DEP has also been re-confirmed ~at the May 19, 1992 meeting of the DMR Instruction Manual Review Committee.

.. - ~.,

.. ~.-

4

- NJPDES.'

8/25/92

- Explanation of Exceedances

' July-1992-t

.The following exceedances are included in the attached report and explained below. Exclusions have not endangered nor significantly impacted public health or the environment.

DSN No.

EXPLANATION 461C

.The. Copper limit of 0.2-ppm was exceeded on the second monthly sample of July. The elevated level was found to be partly from the condensate drains of a previously unidentified air handling _ unit.

This" unit contains copper coolingicoils upon which condensate is

' constantly running over..The condensate was diverted away~from the LVOW system thus 1 reducing the copper concentration and immediately returning.this outfall into compliance. We are continuing with.the effort

-to identify.and-eliminate all sources-of copper into_this-system.iIf additional-sources aro

.found they will.be.-either eliminated or reduced as necessary.: Additional information as learned willibe.available_;upon1 request. Please. refer.to

~

the attached report to_Mr.: Steve Mathis dated 17/24/92.

3 y

t

+

--e

=

w

.sm e

o a

i-m+,

m-

. 3 -.

- r COUNTY OF SALEM STATE OF:NEW JERSEY I, Joseph J.

Hagan, of. full age, being duly sworn according.

to law, upon my oath depose and'say:

1..

I am the General Manager of the Hope Creek Generating Station, and as such am authorized to sign Discharge Monitoring Reports submitted.to the New Jersey Department'of Environmental ~ Protection-pursuant to the Station's New Jersey-Pollutant Discharge = Elimination System permit.

2.

_I certify under penalty of-law.that I.have personally examined and,ad familiar with the information submitted in-this document and all attachments and that, based on my inquiry of-those individuals-immediately responsible for.obtainin

Linformation g the information, I believe the' submitted-is true' accurate and complete. I am' aware that there are-signkficant penalties for submitting false information including the possibility of fine and imprisonment.

3..

The signature'on the attached Discharge Monitoring Reports:is my signature and I.am submitting this.

affidavit.in? satisfaction of the requirement that my signature be notarized.

n

.'Nagan-

= i

((

.o h

era Ma ager Hope Cr Operations Sworniand subscribed before me this: g ;. day of g(,;. 19 9 2.-.

L % c=sh k

.w-

~.

shelf L HUSTON~

NOTARY PUBLIC CF NSW AP.m

. Bly Casunitalon Expires Dec. 23,- u$

L t

.~m.

1-

s CERTIFIED MAIL RETURN RECEIPT REQUESTED JUL 241992 ARTICLE Not P 378 354 59 NLR-E92214 Mr. Steve Mathis, Senior Environmental Specialist NJ Department of Environmental Protection and Energy Office of Enforcement Policy i

Southern Bureau of Water and Hazardous Waste Enforcement 20 East Clementon Road Gibbsboro, NJ 08026

Dear Mr. Mathis:

HOPE CREEK GENERATING STATION NJPDES PERMIT No. NJ0025411 COPPER EXCEEDANCE AT LV&OW SYSTEM CASE NO. 92-07-22-0746-40 In accordance with NJAC 7:14A-3:10, PSE&G is reporting a 3

discharge in exceedance of the daily maximum permit limitation for copper at the Hope Creek Generating Station on July 15, 1992.

The discharge occurred to the Delaware River through the Low Volume and Oily Waste (LV&OW) system outfall, DSN 461C.

PSE&G became aware of the exceedance on July 21 when the sample results were reported by our contractor, South Jersey Testing Laboratory.

The reported value of copper at that time was 0.30 mg/1.

The permit limit for copper in the LV&OW system effluent is 0.2 mg/1.

Upon receipt of this information, PSE&G directed South Jersey Testing to reanalyze the sample.

The result of the reanalysis received later that same day was 0.29 mg/1.

A call was placed to the NJDEPE Hotline reporting the permit exceedance on the morning of July 22.

In addition, the LV&OW system

-effluent was sampled on both July 21 and 22 to determine the status of the discharge.

These samples were analyzed by PSE&G and, although not certified for copper analyses, preliminary results indicate that this outfall is back in compliance.

Duplicate samples have been sent to a cerhified laboratory for confirmation.

S. Mathis 2

. Jg g 41992 NLR-E92214 The cause of the exceedance is unknown at the present time and an investigation is underway.

Monitoring of an upstream lift station by Station personnel did not indicate any significant copper concentration.

Station personnel are reviewing influent sources to the LV&OW system for possible copper contributions.

If found, actions will be taken to reduce or eliminate the copper discharge.

PSE&G has also initiated daily sampling of the LV&OW system effluent for-the remainder of July for analysis by both in-house and contract laboratories.

In-house data will be used to trigger additional upstreara monitoring in an ef fort to locate the copper sodrC8.

If you have any comments or questions regarding this matter, please contact Pat McCabe of my staff at (609) 339-1245.

Sincerely,

[

r.

X. Thomson, Jr.

Manager -

Licensing and Regulation 1

~ - - - - - - - - -

am T.virxcu Ni?.1JER$tY OtPARTMENT CF ENVIRONMENTAL PT.QTIC? SON 6m OlVisiCN QP WATIR RISCyRC13 MONITCMt!NG REPCMT - TRAN1MITTAL SNEIT__

suposs me.

mepontine rsasco as4.

Y m.

too. V S.

[ 0:0! ?! 5! 4I1! 1l l0,71 % ;j Tumu l0,7l 90 l P(MMfTTit; Nam Public Service Electife & Gas Cemeany k

O_, Box 236 Hancocks Bridge, N. J. 08038 PACILITyt Neie Hoce Creek Generatine Station P.O. Box 236 3

Hancocks Bridge, N. J.

(Countyp Salem Tesegnene f C09 1 339-3463 POR$es ATTACHED (IndWurth ofZeeb)

OP3 RATING EXCSFT10tet stuoos mapostTs.sAmrTAmy ves we T.VWX407 T.VWX 008 UT.VWX40s cvs TASTING C

I a- --

o 2

- 4.

Ts.. _

T.VWX 010A 7.VWX C108 wow Tentwo adALPUNCTC4s C

1 9% T' out op oesm4 Ten C

I s

T.VWX411 UT.VWX 012 UT.VWX413 ofwen C

2 caouncovAten asPonts y,.7,

, m g VWX415(A.SihVWX419 VWX 017 N NI hPoss OEx Amos toontTonswe aspcat g,g h EPA PQRM 32;o) trerofabrAm.muursheer;_

..4 AUTHEMTICATIOM 1 Certify under penalty of law that I have personally sxamined and am familist witn tre information sabmitted in this document and all attachments and that, based on my inowry o,f these individua6s imecciatory responsitAs for ottaaning the infotDation. I behev, tha submitted information is true, accurate and comp 6ets. I am aware that there ave significant penattles for submitting false information including the possibility of fine and imorisonment.

LICthS80 071RATOR PRINCIPAL EXICUTIVE OPPICtR er DULY AUTHORl2tD REPRESENTATIVE Name /PrwmMr1 Name /prfmeet Joseph J.11agan General Manager N-ll24 Grade & Rogmry No.,-

Tide (Pr*mw) Hooe Creek Onerattons sp r /k

/

f){ W' g;

\\

c,t,

9/25/92 g,

/9 v

l 4

OP(R ATING EXCEPTIONS Of7All,30 n

==

Houme ATTENDED AT PLANT Mene l0 p l l9 2l y

l' Day of Memn 1l 2 ) 3 l 41, 5 l 6 ' 7l'8l9ll10l11i' 12l13 l 14l18 l 1tl f-

10h-12f 8 l Uransse Oeerseer 8

-l-

-l 8

'8 12 12 5

12'12 Omers J10l10l 1d 3 '

3l10i10410 Id10 3

3 10 10 i10110; Cey of M4nen 17 ISI 18l 20l 21 22 '23 '34 5 ' M I 27il 3-!N l 30l 31l 9l-l Ueenses Coerster 12 9 i8 8

8 6' 9 ceers 10 3

3110 10 l10l'10 10 3

'3' 10t10ll0 (10 l10 l l

l l

l-l

NEW JER38y cis Antuts? C5 (NvinoNygNTaL PRott**.CN ec a f.vwuce Olvis10N CP WATER RESOURCES W

YONITORING REPORT - Ttt ANSMITT At. SMEEL p Pomfino.*ntoo 8WPots ho.

... v.,

.. e n.

I 0 0125, 41 tij toi7 l7 R J Ynav l_oi7 ff J Public Service Electric & Gas Comoany P t avfTT ti t Name P.O.

Sox 2M Accriu "ancochs Bridge NJ 08038 9

.s P t4CtLITYr Name P.O. Box 236

~

Hancock s Bridae,NJCc,vw snie-I<no )339-3463.

Teleporg CPf R ATINO EXCEPTIONS PORV8 ATTACHED /In#/wtf M af farAf Y88 NO SLV048 AtPCA74. SANITARY U

O

[T.VWX 0C0 bT VWX4C9 OY878Tf8NG T.VWX.007 DisNpICTioN INTERRurfiON O

8LW008 REPomis. INoustmtAL OT.VWX Ot9A U1WX 0108 woNitomiNG uALFvhcTicN8 C

Z WA*TIwATER RitoRTs yy,yg ggy ge e,gn43 ggy 3

g Q

E

[T.VWX 012 [T.VWX413 ofnen T.VWX411 CA0VNewAf tR s tPORTJ (praeg uy ayas" n reptr ts/gt

      1. #"#" #"'I VWX 015tA.8)

VWX 018 VW;t 017 NPo88 064CraA08 WONITGuiNG *sPomT 077. m.#eur Ansated 4//&w"e4 iAt rsrerat of this shest murt she be temPlered.

EPA FORM.7320,3 A'JWINTICATION. I ca.tify vnder penalty of law that I have personaisv examined and am familiar with tee Information submitted in this dorwment and all attachtt enu and that, bwd on my inew ay of those individuals immediately responsible for obtaining the information. I believ5 t*e submitted infortration is true accurate and complete. I am aware that there are sigMficaa penalties for submitting f alle information includir'g the pouibility of fina and imprisonrae PRINCIPAL. EXECVTIVE OPPICER or LICEN$ED QPERATO A DULY AUTHOMi2E0 REPRf3ENTATIVE A Nhe 5 NU Fk _

N,,,torine,41 :.1.9 eeh nanan Nsene (Printed)

General Manager.

Cr.oe si egio.y he. [ I' I JV f4 2 )

m e/prin,ed/

P* Cr**k erationS

/

M%

sinnuwYI W

=

^

2d2j sunm n N4/%7' 0.,

o,,

- ~.

oPtm ATING EXCEPTIONS DETAttto,

)

S

-0 W 0-2) A L cda f

- L a!L L'.e a d s - A t~ -

f f

v A&

f f

hot >R$ ATTENDEO AT Pt. ANT Month Yest b Osv of Monm I 1l 2 l 3l 4 l 5 6

7l8 9 l 10l11 l 12l13 14 15 l '6

- Usenwd Operator f [_

[ b l[ [ [I b ' di [l[*

~

oe., 2 \\2 l212 l? 2 t212ipi2 \\1212172 LO o.v.t u.J I nl isl iel al 2i ni n 12412sl :el ul 2sl 2si ni sil une.e on.r.ior IdI l

16 66. Is A; I41416 6 16 l' o n., \\217 l2 \\2 212 62 \\212 2 \\ 212 lp L2 La l D

PEurYTsa unue,acoases (Iactude e.a r ece. a t po s.t uv ant o.sc m a c a s uas. a v o s v < s w VOL S/

Fadhry Namelineeska sf &fferent)

Di:CH ARGE MONITORING CEPORT <D'IRi UN'iE_ - ESEfaB _ _ - _ _ _ _.-._. _ _-_ _ __

1 16'

!I ~ t 9 +

porm approveg

._ E cD n_.BD X_.23 6/N 2L _._ _ _ _ __ _ __

NJG025411 461A

~ l oue No 2ce.o-coo 4.

^**T**

- ~-~=]

Approval esperes 6-30 9L

___ _ __H ANCDCKi_ hEU)G E,NL Q 60 38 GhN TWM RWMM gon,7on,g g pg g,gg enciu ry

_P ig f,G_b'lE E_G R EJK_ G E NE R A TJ N G _ ST_

MAJOR SALEM

-d1 r o ',,9 2 G

REGION

{m-.s;b- $b SOUTHc kN s.ccar roa 20Mf.B_fil.QM&RCREE,NJ 03038_ _

  • ao*

w ua DMR NUMBER

  • 92070486 co2n n12h r24 2 9 r.

e an/T NOTE: Read nescucteons be' ore completmg ttus form.

~

K v c -a o,1,3 ouaurivv on tonosus c e <,.,,4 3 ou.a r y on concaur= Arie

' "* tl,P" s a,u,*; c

,aar.weran s

w 5,3 m 4s>

ou5, 4.u i,

mi,

~o.

  • " )

x m m xN v m m xW x m m xq u,.ir.

^l'['

vwmuxx xx. m w xx

w. i r.

,,g TEMPERATURE, WATER

,t e DEG., CENTIGRADE i

EFFLUFNT GROSS VALUE P "" '"* " * "7 i,

        • ~ ******

~REPURT 35 6000 C De6.C EGhiAn -

00010 1 1

,a n u ir j

UOUS' MNTH AVG DLY NAX TEMPERATURE, WATER W dic

~

,,u

25.9 27.7 cont l DEGu CENTIGRADE "E^""*"5"'

00010 7 1 16346W4.

    1. Wff*

REPORT REPURI DEG.C ~CUNTIH

.,rstw ir INTAKE FROM STREAM MNTH AVG DLY MAX 1

UOUS-PH

  1. 4T***

4 u e 2.*u"n7da u, 7

8 1 0 2/wk Grab 00400 1 0 444WWW~~

        • T6.56006 T-~~445600 9.G0000:

50

--TWICE75RAN~

,c.u,7 EFFLUENT GRUSS VALUE " " " ' " * " ' " '

        • MINIMun MAXIMUM MEEKP SOLIDS, TOTAL e66648

,,u, u 138 150 2/mo Grab SUSPENDED "E^.unewaur 00530 1 0 scFfW C~-~4WWWe*

        • % 4***

REFORT REPORT-~~ MG/L

-~THICEFERAB-eri. u,y EFFLUENT GROSS VALUE MNTH AVG DLY. MAX MONTH SOLIDS, TOTAL

  • c****

ura u,u

-1 15 2/mo Calc uaeuaur SUSPEtiDED OO55J 2 0

          • C f6Td**

KEPORT REPDRT MG/L zulcE/CALCTb

,7.w ir EFFLUENT _ NET VALUE MNTH AVG DLY MAX HONTH SOLIDS, TUTAL

  • S4 F53 u nle'u"n?Een,

140 144

- 2/mo Grab SUSPENDt D 00530 7 0 (WF4CW--

        • - W&Fe**

R E80RT~- ~ REP ORT-'- P:G/L TNICEIERA F

,s.u,y INTAKE FROM STREAM MNTH AVG DLY MAX.

MONTH HYDROCARBONS,IN H20,

        • ce

-~

N 644*

,,u,u

<0.1

<0.1 2/mo Grab IR,CC14 EXT. CHROMAT

"'^*""E"E"'

00551 10 sit f4WFf'

- 8F# **

  • REPORT R EP URT-~~1 HG/L gaucc/ GRAB--

,en u,y

"*"'"t**"'

EFFLUENT GROSS VALUE

MNTH AVG DLY MAX MONTH waurfr von p sci,ai. exscutive orricea ',g a'p, ga g,",, *g ^;,'g g,;<'n,*f5g*ggag 3 1

Ta'aracar oa: e a. i t1 m.

_.. _.. e,

_.~.m-......,._,

Genera 1 Manager

"',^***'" J"o' 7".oL, M "l. '."'..?"*".'"',",,,7 *,",,' ' 'Of 609 339-346:i 92 08 %5 I

Hope Creek Operationi

',"l.," *,f ' 4",^,' ' */,'f,"*.l",,*2' *T,,, '.,^0' s,M"u" '? "*. "%'y "*;r; L

G~^'

a*

  • c'**"Ec""

nosc.....

. r.

u.,,,

,.,.,.....~wr.,,.,,..

u rv,.o o. eniurao

...---.---~~~~.~....-4..~.

./o

^"f" ~ _wo u n e. Jvaao I

o,,.

u s,0,..n o moanr uo ca, 2 wMPt'IMEM'ttR"c% '2 sty vaCh*IS*'REQUIR1E&09A:T If MIINTTNdNCE CMhTC AE5 CDMTAINTeitT~THCTHETAC5 ARE USEDM ~IF '

5 E

NOT Ust 0, ENTER 1 " NODI" FOR THESE METALS.

EPA Form 3320-1 (Rev. 9-88) Prevtsus o. irions may be used.

ggc as cea comu t-ee wnu u n v o,.e o,s,e o_ _CgC7ET75{_011

,. f o,

m a roon a t ro ttur = v o.sc 4 =se n.,=.,,o.,

, v sre w i.ston penas Tyss nausianessass llac/=de DB2CH ARGE MONITOQlNG REPORT <D*fA/

ttAns_'ana/Locarba if dr/farata__2.SEfG_ _ ____ __ __. _ _._._-_

f: 161 ft?It Form Approved.

parf.2ry /

aaarm

_e D _BEK_23MM2L _ _

c.s 025411

!461fA OMB No. 20404004 l---"--""

Approval expires 6-30-9L

  • a a ' r a u" ** a

___ _ _.___11aNCDCKS._EMRGE,NJ__0M 35_ __ _ ____

i u,on:Tonina rcaico MAJOR SALEM

_ESE34_EQEE_CBF EK GFUERATING ST raciurv MpM-dl-SOUTHEede RF610N "N

D di-m I IONT

_LQWEB_JLLQ1A)S_.CREEg4J 08038 rao=

vo DMR NUMBER: 92070486 au ne am ue n, aa n raw 7hTTTT NOTE: Read ensducteons before cornplet,ng thes forrn.

(1 Card Omtr) Qu ANTITY OR LOADING 3 (d ( erd (6edw)

OU ALITY OR CONCEPs,R ATION

' ""j[

$ ^ "p

  • no i

(ISW )

(44-33)

(3441)

P AR Ald ET ER (46$1)

(3448)

('D

XMXMMhAXX XXUO G WXX uniTo XXKXKXXXX XXVRVMXX XXXMKXFX) units

,m,,

H7DRUCARBONS,IN H20, s a u,L.

<0.1

<1 0

2/mo Calc

"'^*""*"*"'

IR,,CC14 E TT. CHROMAT 00351 20 1,anuit REf OfiT.

10.'~4dsjin:~ MG/L TML"WCMb I MNTH: AVG DLY MAK MONTH EFFLUENT NET VALUE HYDROC ARBONS,IN 620q ""^u.n,

<0.1

<0.1 2/mo Grab suanueur ILgCC14 EXT. CHROMAF~

~******,

96-

        • ~4*****

REPDRI REPORT MG/L THICEFERAE-i 00551 7 0 hs MNTH AVG DLY MAX MONTH

,ca.,,r-IH7AKE FR0M STREi.M F50SPH0h35, TOTAL u.a.

0.26 0.29 2/mo Grab

""^*""*" Ear (AS P)

- *s4M*

        • M REPORT.

REPORT iMG/t T H CE/GRAC 0G665 1 I HNTH AVG DLY MAX i

~~

MONTH EFFLUEA GROSS VALUE ?'8"'"*"*"'

PHOSPHORUS, TOTAL 0.03 0.06 2/mo l Calc

  • uom.

" E**u a a " ENT (AS P)

          • c KEFORT REPORT-MG/L yedICEFGRAE~

00665 2 I re..,1 MNTH. AVG DLY MAX iMONTM

" '* ' " " ""').

EFFLUENT NET VALUE PHOSPHORUS, TOTAL

    • C***

u n,

0.24 0.26 2/mo Crab

""^.uneueur

-~TECE75RAE~

(AS P)

' REPORT REPORT PG/L 00665 7 1

. esau er MNTH AVG DLY MAX

.MONTN INTAKE FROM STREAM

" P """*"'

+

CARBON, TDT ORGANIC y,y, 3.0 5.0 2/mo Grab arasuat= car (Tac}

~

00680 1 1

- ec= u i.'

8*****

REFDRT REPDRT'~~lMG/L TMICE/MiXD-EFFLUENT GROSS VALUE MNTH AVG DLY tux

~

MSWTH CARBON, TOT ORGANIC u urta 0.6

<2 0

2/mo Calc.

"'**"""" cur (TOC) 00680 2 1 renm er 1******.

P.EP 0i'T'

. 20.e464&~ MG/L

.TMI4EvGRAE-MNTH AVG,

BLY MAX MONTH EFFLUENT NET VALUE j

T E L E,9*O*e E DATE EN t# M Yv C f

i

  • t *"it At V D

N AME/ TITLE,#3NCE,AL EXECUTlWE OFFICER J.

Hagan g,,= 3 g ;,, y g y, p g';, g g,l 4 Genera 1 Manager L ;"',", ag,oaa ',', ^'e,, ctg'l,' ' ^,am ;^* O, Z*',, ** y,,,q p 609l339-346] 92 08 25 a

Hope creek Operations

'l* =l7,C;~',^ *, C;lr',,,;',Ja,y,$2, Z;,,***

,o ~, u.,

,.,,C,e*

.mecuT..

-aar pij

..,c gg,,

m,.(,mmu O..

,, o o,,

.,--.c.-_,~_--.s-oa..".--

O,,w

'5WMPU ffS'FDW" CUP"ZW "cCR"IS'"REQUIR EtT"UDE'Y IF MAINTENANCE CHEMICALS CO YU8i 5G TH IF

,,,, o C.,

,,,,, T, o tJOT USED, ENTER "NODIa FOR THESE METALS.

  • m v.,,,s c.uwca rn,m graw ampes.

e s era Foaw T-** wmca e v nor nego s,051_5{l7,4]_7,7pj4h

~

ease 0,

EPA form 3320-1 (Rev. 9-88) PtwWiious editions may be uset er a

p_

,o lA l

I l

,4 N

mu h

w g

  • H t"! *F c N
  • i d

4 i

i W I "

1 I

1 3

W E

l$

0 5, E 5,__ "mI

~ ~l e i

I*

O o

g

=

3 QX WX d3 w

J g.

42-

u o L.--

-m

t CC ngm E ~~~T-

~

~-*~~*

~

l l

l l

4 49 0

0" 1

l I

l y

,al 2*

eQ

-r y

1 4A m

<=M m

g h

J J

J J

J J

J N

l N

a m ' *).

O

  • m 2

!j

}

I o%

7 E

=!a _K

_E G

O i

O 0

3 C

0 m

w i

E E

l E

E E

d 1C y,1 Z

H S ge$%

cn r

g 3 5A w

X o $

n

u. O T "o o

<e

'l x5

). M H

HM H l M H

H h.

H Hg H

g H

4M w

&l C at W Q O4 C CC 1 O M4 O o ag; O

gg gw g

l 2g *97 O

!g (

QE e oE ooE eoE eoE o oE eoE

_2 [w ri c

V i

~

=%

~ c

~ b

~ A

~o A

3 gn a

uJ a: ;0 4 k>

O>

W>

!yO o>

w>

Lu >J N.A is J u

MTI - e

<2 b

JQ>d X

.nl 4.J N.J DC J tg.

C "1 3 o ;w A

A eA A

A eA A

. *3 H L

2 L

Q4Q Z u X

UEW i

X m.

a 8

w u

a a

w w

a s*w m-H 38 H

HD H

HD H

HD H

HD H

t= >

H HD

\\j z 9}a "f,1

>*T'R $2 O.

kg 4 O ct 4 0 4g 4 O

M 4.0 12 4 C les 4 O cc 4 ij I

4

't '

nC

o o u oo o o O m o o o kI w% 'p t

a 35 o

7 O! h.

Z s Z

Z A2 A3

A2

!v m

hm2>

w tu >

W l.

w>

we

$l 3

x

c. e -

11 2 fM in M M3 l0 31

  • >. ?

5 ch /,

X.

?E

,.,E E

W gl (s'%

a g ? t 'v E

. g ;4 O 2Q v o

E t

l "O

t O

I J

~K lz.!

ll lhe

?L s

X g

i 6

2 s

e J

w

_g 3

  • u U

I2 l#

l#

  • 4 ~ ' (#

10 ')

lE "I

E 0

4 9

t#

t#

4 4

4 v*

iw

-l io O L>

l2 1}

0 je 4

6 9

4 e

O k

'C 4

L d eI!;:u.9I

Z e

'o

  • ii o

=:

p Ln

u
i g-3e I

1 3o 4

'O M

4 4

t#

4

[k ! ]f )2 l5

$g [

f#

l" ff f

{-

I O

>.4 l4 I-m E g.g 7 s' D

's II M

.u 0 4 5clI': s IE e

n2 3

O s

g#

r- ; d tw

w - n 3

2 #* 4 i

C a

go {_ ?j.;;M g - Z

}

< 0 f. N z

20

$2 dC 2 o I

r y * * !;?

3

M s " 10y j

z a

1 l# -

l.

l O...

g pld

  • i !! jg sZ em 3, ;;

y 1 -yi.

D X

w

,E r

W* #

F' #

  • p 4

.s t

2 i j },a 2 3 3

6 4-

< +

4 3 * : i s tw

,0

s 4:

$:A:M

. M '1sian ti l>

I

. p 4

3 s it e

r(#.4 i:

o

" 'i ! --

2' O'

4 a

m A

e-e 1

a!

10

  • 3 d a,; *h C

X B}g t

J j e

4 2

m

.J l l ;

I

- ' I HI I' Y

ot* v **; y,a i

o x

"/ ' 9. $ 3. =8 j

! O 4 v
  1. 1 '

2 ~ #

lWlm}

M.

i ! i 13 (l wH s-i i t I

I :Z!

C 4-2w rt

  • I ;. eD$b iu' i ':

I i

E M E

w t

,1 z 4

=

W 4

J- #

6' s+eI 5 :,I l:'1

'MlO!

{3)!y d-w 4

,7 9-W IfiCI A

l l j eCl"I{

y

!jQ)II;j[ccw i

f*

=5 O

,Q l lY ;Wl2l

,i T5i 1

  • "{If 6

"6 6

5 6

3 6

5 5 '-

"6 6^

6 6~

C(i

'l ww ii ' m w!

32 tg 2

22 "X

'ta

$2 Ex' 51 tz 3

ty

$2 t1 25-D

  • E Rw M

L

'3E 3"

'E 3"

g5 33 g3-

'3, E gg.

g3

  • g g=g3 gg' g -
E Q i Is

'3E 2 "5 E

3" 12; t Wi v{t i

6$

3

{ g

/

3 3

l e4-a 3

3 g

sg e;

sg g

j.,

ig ej sg t

e' 63 m

s ml sj.

my o

e

' N; wi jwl I e

j/ \\

- w a

01 I2:(& i wi ni W3 i gi pt

/

\\

w w

fu w

a w

w w

w w

w w

j g

C l a

a ak.

3 E

2 a

2 m

I e-2 e

N ml luf sl4 w

-W--

I wl w 0

U D

D E

  • J mc

%l Q 3

IM6OC{ Iwl"5l C N

o#

E J

w E

J w

E a

t I Ml mi I CI JI N 4

W J

w

.J w y

. O o oz E

I I I 161 Ji C 2

4 4

3 4

et D

et 3

ok w

N L g

D4

- $m 00 e

a J J

4 J e

s x

p jot w IIliq o E EJ w I

=I CQt U l I IN

> 4 A 4

> 4 H

A H

o el et e g o

m Hm mHa rm m,J e a gm a

co

<$ 2 4

w a \\ cl e ul g h = g [Iwiwi L

H gm a

o c,q p og ca cg H cg gg w

a-v w Hu E s ex

<w jwlpg ;;g H

E Hu

= >v w.- v E Hu

,EQ

o. p E

w f mi e m

Q c

c

=

c c c c g c c z 6 0

I H

H%

  • MC
  • OO
  • WO4

>Wo HMO HWOE e

w a

2 { Al a l ] I Al d W:D E w K4 b E4 e= E4 4

4 W

4 at a

6CH b CQ 6

8

  • l I I I t i

<$i1 1 1 i lE DwN2 DwN2 3wN k v e4 2 mwNZ kwh w tD d U K a 4

E.

db N e N

m' I I I I I gl 3 2

wl>;

'% 0 0 w M w M w g w g w cg W

3 E

l $l 1 I 1012 Qao'K

  1. D E
  1. 3 E
  1. M w ND w

ND w NM

  • C Q.

g I w.

I I i st CA W 9 4 Q M.J C MJ C

m%4

  1. .J A
  1. J L
  1. 4 00
e a,

IM

%Q4H 0:

Cw c1 Ow CE QN A

Cw A

Ow b QH 2@

lll IE 4Her sw I

sw

=

dz o

3

<tl o :

@c 4

4 c4 w o wz

.4 wlo

=3 Z

g Z

Owu Ow v O>

k l l 4 lA WwQw 4

Ow U

C l'J. V O

>=e v

-.... _ ~ _. - -

.. - - ~

. - -, ~.

q

4. I ~ o>

af ga, W N

.(,

4.

e i

E g

t i.

I ;

4 e

k O

U U

o 2

e

~

!y.

l e

ofjw" Q >g.

-Q hg Q

lh k_.- o(

m I

i

".,.j E M

yh lW M

Oyp O

O y

v p ye E

E 8

55 k55 k UE k 5 d

$ ${k SE Nl3"

' hl '.

5 O

ME "FR N

HR N >

0 95

  • >w 3,24 5
  • Q24 E

n

!E Wo 0"

1 1

i e

i i

i c

t4

    • */

eA y

e 0

e3 2

1 m

g o a

  • Swo i :: J e

O 8 g 'a J J

o J

J

.J

.J

.J J

  • >et e

l u~

m 2

i 3

g

!w n

c ga aE 3

e a

a e

a w

5 W S E

E E

3 3

3 w

- :E O3 7

mdd v1 Ed W

62 2

w X

l j

o a0w "9

a m

m n

uO o

m o

o o

e :< um s

yrx p

n,!,y5

- *51 g 82 g ;5.:

8 51 :

=

x o wx 0

o >=.

f! !!

8'82 =8 2 8:

e a

w= n x

x z6

.v.

I o w>

uj t.*

s A

W>

m )s o MI >

o

>d

- M % Z gj Ef#

lI * $

[

O40

W Wk dk$$ e X

h

,d C

E V

V !

V

'z Ia*T WEM m

n 0

9:

4

_ l
_

o >< < o !>.

H H

H H

H g

%, i '

w.,-

.o u

o..

o

< c i.

o s..

o 0

Q O -

O Q o

o o

w a

cl

~g l

  • nt 4

=

2 Z

e. 2 Z !

= 16 3 2

l

  • A an wEI.

w o

F o.

w>

o 3

w>

w

s s

-:9a u3 l.

A 3l

  • w:

J-r.

3 y

at 5 y

a3 y

x

  • 3 a
  • g t-C l 0 iQ 5

E E

E E

E a

J g

't X

-o--2 x

g so c4 x

(<*

y gi

  • u a

b W tNe

2..-

3; 8,..

m,s$m z

i=

e >

n E

o,

,_ e -

w

,o u n z

o n a

=

"1.9!h.,i!!

ij 2 :

3 ii l,

,_ :P M.* ;{0 i

.tJ -.

3 a.g

-1. 9 l

m x

O u

4

~o ;

1n 5=

t :

2 0

z 2

  • 3' f u< r. b ;

ox a

=

2.

O

w n,,

p c u-s or 1

a m

.oe N m

=

u r6]Td 4.ib 2

R t i

e

,x.t.-

l

,i vlj,r m,,

~s a

=

2 3

E 4

z 4

n p s o

i aa h,a.I n

,a

, :- x

=

n W o :4 -2 e

8.

4

- M 3.:=8 e

g.n.

m 4

.>.is m

a 3, L e ; 2 v

x

=

%u.I. o z

'yb.D i,i jl.

l M

l!

lgl 1

X e.

2/I 4

bd

'h 3.!:g;!

x

.w M.

wE

. lcj.;

i o" **

iu -

lIg!-

!g[ !

k!

5

!!!~*

S r%n:3a l l l gg ta

=w l

f g

e Lp88aMhm 5 1

1 e

j

, o i 3 1

i e#

31 et

- e;t33,(1 g

1* 3 e

1 e;

1 e;< l1 i W -M si 4e;; s:i

=

1

!!: l gr ll

^

33 1:

l J a j es; i:

It

I.

,33 5

lNd

! ri. ll f[ !! ti 25 ai 'Ejv :$

t a"

[

1-V[ y a

gd wg s

4 1

i i

I 4

w w

a.

Q O

A 1 M 01 lu13 so 3

3 ga 3

-t C

w l

- I N st I wl oi a

.J w

E a

.J a w e E o4

.J E M

2 e

l j L' JQ 4

3 4 0 4W D A 4

.J W D 4

= o S I_j i q w' t Cd.

4L E

D Wkb

> w b** e MV W

D

.J w 3 33 d 5 i zi o

a s o o

z.

ee g

M W

&G E MW es leu I I N

A i

g d 2

> g E"*l 2 m j CO H

e

  • Dc z a

m o

n W m m m a

e e 3 dlMp e

2 e

a 2

w a m

> w aw o -

c o

oe Q4 l uj 2 **

yE

.J N

%.J N w.J N E W W W w W E CE E

U C.X CW a h E

G 84 IW Q 2 4 2 4

Q C Z 4 C w

@w Z w Q uk Q

2 EQ w

a-

>mo

>ns pmog o

o og go a

C 0t w

a 2 NNA J Ll d w MC

(

4 I I i i I I 80 l

C4

> C -f clO (

4 m H A F A A 2w k

C c-4 4

=

2 l l [ l ! !E W w e4 2 >v i

p= w f*=

C c4 2 Q N2C r=

M g et 2

- GCU Ew l

w W W w >

w >

w H

w d C4

%e et

'I i i I [i gi 3-D N3

'Y Q >

NM W W3 A

O3 MM Q3 E %CG

  • W 3 E

U Inltl.I l Cl 2 l

I U

e.J v 7.J v e4 w

N

,,,a w N.J w N at 2 3 in.J ;

cG 3

3 i

1.31 fI 00 E*

u.

[g 2

oE 2

OE E

OM M

Nw A

NW m

NW QEo6 a

3 l

l L dI y' i =

h0:

O

.c l

IE H

eq 6 H

e4 W M ed 2 M W

p&

W

  1. 2

.J Z O w <

-a i

~

ow

~

ow

~

od mw <

mw <

wm o z

e r

i

esmessTTse n Aussapouss8 (locJisds navsommo coowv v o sc=aase me.=.

..o= evsre.a MDEJ/

Facshry #seM/locarbe (f Affersar/

DISCH ACGE M3NITORINS GEPORT idef A>

mAnts__ _

_E 536_ _ _ __ _. ___ _ ___ _ _.._ _ _

f2 N ffT16 Form Approved.

M.!G'l!" _ _InDa_BDK_236/N2L _ _ _ __._.___ _,

CJ2025011 461A ov.8 th 20404004.

___ _____ _ H&NEQCES._BRI_DGEtNE.080 38

  • E=MirauM.e=

..u-.u--"*

Approval e@es 6M.

umn ma mum uou,7cy,u, pgy,,,

- raCipev _gsfEg_morg_ CREEK EENERATING ST MAJOR SALEM M-D db T

W-&

' SOUTHERN REGIOh

_L QWEB __A_L_.L O_MA_y 5__C_RE E nNJ_0 80 38

_ar M rao=

1

~DMR' NUMBER: *12070486' no ni m.2>>

<24 25, v2 27, <2s 2.,

<>asi, NOTE: Reed instructions teefore compteting tous foim.

(J CerJ Omip) QUANYlTY OR LOADtNG (d (esd Onety) ou ALeTV OR CONCENTR ATION PA R AM ET ER

' (d6 31)

'($44f)

(JM J)'

4 46.J.f )

(Jd4fp eeO.

      • C'

' SAMPLE

("~###

Em TYPE

^ ~ ^1',

X'4XMXMXXX XXXMMEXX uNivs XXdekMXKX)

VXMMXMXXX XX)GtJW(XX u T. '

CDE.ORINE, TOTAL

      • eGE

... rt, RESIDUAL

""^*"**"*"'

<0.1

<O.1 0

cont t

50060 1 0 T, R.,e.

.5.- - - - - - ;

x -

        • N~M

.h MG/L s.uss saa i

EFFLUENT GROSS WALUE ""*"'*""W

~R i

4 SWTHEAWS DLYx RAX '

M51 in p

HEAT (SUMMER)

.,,,c, 163.5 242 0 -cont.

Calc (PER HOUR)

"E^SuREMENT l

D1336 2 1 (ADMIN)

. Faanm er

. N T;.

MBTU/ - Wa****-

Fet###

Eau s --- = = sv EFFLUENT NET WALUE

"*"****"I MMMENISSEtid HR

, - ~

USUSJ

' S AMPLE M EASuREM EN T i

i

g h.

5-5h.

j pgem py.

%,e

.4 4

nseu.as

==t s

i S A M PLE MEASUREMENT k

pg3W gT '

R54ul45m EN*

J U;..'

'.j'

~C

. x j$;~

E !I Vi m i

4 -.

y S A M e>L.E MEASUREMVdT

' P.e.n.u., r.2, 1

in

.s p-

~;m e_

~

d

.y S A M PL E MFASUREMENT I

:-,.ennusv '

?

c 480U845m SMT- '

J:Q.

1 s

w--

S A M PLE MEASUREMENT R

ms.wir s l

neemasmsup y

gg NAME/T87LE PRINCIPAL EXECUTIVE OFFICEM l 6.W"ctRTsFV. Asest s.A

&,t.w THa, t Uh0ER #'E h.L YY es.wf et NLv g a eest o TELEPHONE DArE AM met.e YME eN f flW4. aO8e Sue.asT,f D ME nt see e e.%4 0 J.

IIagan o.v.".',~c.

=*'a.' * =vo',-=, e"L.' 6 =i.m..sto" r,i. o'~.~,=o..o j

  • o'* "

~5 1

General Mana9er

's..'c.u,.c.wo n..,~o. c o.

n on c..

... w 1-s o so.

.,c

.o l

liope Creek Operations n u s t i n..","a o ~~ ~ '.",, f y

609 339-3463 92 08 25 i

'~* =~

a* ^~

5 2* utc

  • a~o u n iNc.. u uEcurivE

~...

TYPEO OR PRgNTED ad'****'"*'**'*F**""""'**dM***"*"*"**''

~

MA.-.

AI O F8C 08 M'iI2E D AGE.NTNTUG THEEMETAC5~AM UIHO

ggggg, ygA,

,O Dg, MMPEPN5'YUW^I!ttho'21ty T'CR*I5k'Rf961REF"9NLW IF M5iRTEWAWE CIlEMICALS NOT USED, ENTER " NODI" FOR THESE METALS

EPA Form 3320-1 (Rev. 9 48] Pivvious editions may be used
e 37_emo _O8153 _ V.31L_,,,J.?S15._M111 eAce 5*'

12

~P2asestTat se AweiAODRzs1 (facts.de n a veoa.L *odu rm.o r nasc.mca e i.ee..

.,so= e v srs = c3rpf D

~I Ferirry #sene/facat&He af de/fsear).

O12CH ARGE MONITOllING REPCMT iDefAi EM*I_ _ _ESEEG u_ _ _-._.-_ _ - - - _ _ _

/2 /6!

/ / 719' Fosm Approved.

^ * * " ' *___Eedia BDX 2 % f M2,1__ __ __ _ _ _ _ _ _

NJO325411 461C OMB No. 20404004.

}

-- _._. HANC0CKs _ RR Y DGE,NJ_08038_ _ _

  • ca"'rau"**a

~ ~ - * - " ~ - * *

  • Approval expires 6-30-91, j

MONITORING PERIOD

'Acti17?___ESEEG_110EE_CREL.I?_GENERATJN G _ST_

MAJOR SALEM

'"o" 92 Gi Gr To 12-Ob,31-SOUTHERN REGION i.oC Av.~ N LOMER_ALLQMMS__CREEeNJ_080 38 DMR NUMBER 92070486 iulli <22 23r ne a 12>25,2s la, Jo nj NOTE: Read iPstructions before completaris tius foem-

\\

( A Cerd Da#p) QU ANTITY OR LOADING (4 t ard Omfy)

QUA..

(.6-S f )

(344f)

($8 811 W '86

($4 41)

    • O N

XMXMMXKXX XMXMMEXX units XXWMKMXX XXW_

VXN XXXMKW X) uN.T.

6, ][][,'

TEftPERATURE, NATER

=E A AonE 20.8 23 1/wk Grab unawENr DL,..

CENTIGRADE 00010 1 1

- nnu i,

f..

38*****

RErtfAT~-

REPORT.

DEG.C

- MEEEL1SIAS.

d EFFLUENT GROSS VALUE MNTH AVE BLY MAX PH g

3 0

1/wk Grab 00400 1 0

. een e sv.

Z ::,

N******

        • 6.seems.

9.OOOOOc SU HEEMUM i

EFFLUENT GROSS VALUE **'"*"*"I Y

        • NINIMUM MAXIMUM SOLIDS, TOTAL

. A.,L E 5

7 0

2/mo Comp SUSPENDED 00530 10

. neu er -

8989**

30. W WOOC 100.00000C nG/L TWMAemE EFFLUENT GROSS VALUE MNTH' AVG BLY MAX MONTM HYDROCARBONS,IN H20, t

. A u rt E O

O O

2/mo, Grab IR,CC14 EXf'. CHROMAT 00551 1 0 renu sy w*****

10.dDOWUE ISTMOSSI MG/L TWICEvaarna-1 EFFLUENT GROSS VALUE fWiTH AVG-BLY MAX MONTM NITROGEN, AMMONIA

          • W
    • 8888

. A.,L, O

O.43 0

2/mo Comp TOTAL (AS N)

"'^*""*"*"'

00610 10

        • ~#*T***

3 5.- _ _.

REPORT.

nG/L Tu1 CEPT'DNPG$

+

MNTH' AVG DLY MAX MONTM

~

EFFLUENT GROSS VALUE CARBON, TOT ORGANIC

. A.,t.E 2.6 4

0 2/mo Comp (TOC)

"'^*uREuENT

        • ~*58M*
rep 0RY-~~N~

MG/L TMICE/sman 00680 1 1

. ennu ir

~

EFFLUENT GROSS VALUF MNTH AVG-DLY MAX-MONTH' COPPER, TOTAL

.A.,E 0.126 0.3

' *1 10/mo Grab

"*^*""*"*"'

(AS CU)

REPORT

.25558-MG/L TMICE/dRW-01042 1 0 T

reewer MNTH AVG DLY MAX MONTH EFFLUENT GROSS VALUE s

NAMS/ TITLE PR.NClPAL EXECUTRWE OFPICER 8

"M

" OF i

'***7 8 8'E L'

f**

D TELEPHONE DAYE a.

Hag 3n o,

.o

.ts c..,et.

sm s...<,

  • an.==cau.s..o,o,t e acco.aan=~o.co mvv o. n,-..a. sus r, eo
o. e s./'

ve o.s. r u

o vm a e v

v

.rnw Genera 1 Manager

/*

~A a

.r. o v.

w

. r i.or r

<.~ v ev t ve s ecu sio

  • t se

...o Hope Creek Operations

_8 25 L

cs su no usc u o u s

.., o..

. o -- ~,

609 339_.. _- 3 4 6 ]92

.o0

~o 0

c,P*

. acu rivt o..

.r...,~.....f..s, TvPED OR PRtNTED

  • ad****""=******'*""******'**"***"*'*'**d*"'*

OfFt E

>M AU HOPtZIO AGENT A _

NOMSER vEAR 92 0 DAY COM M E N T AND E M Pt A N A T 40N OF A N Y v eOL A f sons t hr/ eses.c s it n.n hasco,s he e p

~

[

Permit requires composite samples.

    • Pleag refrar to the explanation of exceedan &
  • he attached 5-day report.

I EPA form 33201 (Hov. 9-88) PmWous edizionc inay bo uw '

"I'v No T. useo s 0A153 L7451 775 3.5_LLL.,L 6 ' 12

t PitausTTEs N Aus,ADDRass (Iadeds

' m a r.o.e at *ottu ta e o.sc.*mase s t en.= a r.o= se sem aa iAPDit Faegery Namee/Locusion if differess/

DIOCHARGE MONITORING REPOR7 tJ6fA1 MAlllJ - - _.ESE 6 _ _ _ _ _ _ _ _ _ __ _ _

(2 16!

//7193 Form Aopeoved.

i'==__ _E.Iht_AD K_234iK21_._. _ __ _ _ _ __

NJ0325411 461C OMB No. 20404Xc4.

7

_ _ __ 9aNCDCE5_BM DGE,NJ._oso 38__ _ _ __

PER=1TNU-Ea Approval espires 6-30-91 LOW WOLUME WW SYSTEM

- - _ _ _ _ _ _ _ - - ~

MONITORING PERIOD s,eTv--

E CREEK GENERATING ST MAJOR SALEM wa vram

  • 1 v

w I

'aoM M2 GE Dab

-YtMo b SOUTHEcth REGI0ts LCCAT80N _LQWEB_AL_LQWA_YS CR EE,MLO_80 38___

v vo DMR NUMBER: 92070486 rio 21; a n h tu 25,

7. w n 3,

<f5777 NOTE: Read instructioris before completmg then form.

(1 Card Caett) - QU ANTITY OR LOADtMG

' (8 Card Oety)

QU ALITY OR CONCENTR ATION P AR A M eIT E R (46df) -

(3det)

( W 1) 446.30)

.(344J),

8 "",

NO.

4'# #')

a~atTEeS XXXMXMXXX XXXMMMMXX uNnS X)@9004(XX XX%%XMXXX XXXJtAXXX uNus g,

n t

IRON' TOTAL

  • ^ " " ' '

i (AS FE)

""^*""*"'"'

l.005 1.230 -

6/mo Grab 01045 1 0 EFFLUENT GROSS WALUE "'*'"*"*"'_

W::::i REPDRT E.

REFORF MG/L Iu1EEPM'~

,E R w T. -

a!

8INTH AWG BLY MAX 3 19f131 u

FLOW, IN CONDUIT OR es,e e

. A

,t, O.007 0.01 O

Cont THRU TREATMENT PLANT "*^SuREMENT 500SG 10

=,...,,

assggy y s f____

secess

emgg

. g3,33, g,,,,,,,,

EFFLUENT GROSS VALUE ?'"'**'* *"I BW9lfACM,,Y3 MAN O : MED oce 43333)

S A M PLE MEASUREMENT j

PE RM IT RE4Ml84EMENT S AMPLE 1

MEASUREMENT PERM IT F-R$4MAIMEM.,ENT a

C A M PLE M EA&'9 REM ENT PEasst? -

E,"

H

' ' w.

RSept4Ea6ENT.

?'

?

S A M PLE 5

M EAS UREM EN T

, ' PERM IT '

s ASWBGSM Et(T

'e g., '.j

'4 S AM PL E MEASUREMENT i

RE'WIREM ENT

  1. ,. L.~.

i g.4 NAME/TlTLE PRjNCIPAL EXECUTIVE OFFICER e (tavery taeoen M%AtTV or ( Ass TMa, s Mavt Pemsona a smeewet o aseo ame saaeis sam evivee vna s.wosesmarnase (muenevigD g seg. tty TELEPHONE DAYE e a.so anasto J.

Hagan o., a".'

c,

- o.' o.st = e va.*

  • 5. =5.=,."v.".e,ri.m,sa a..,o.

1 o~

== * ~

a

>~

  • =

v rm...

o o

General Mana9er

  • "a*~*, ac mai,."s a,ao., cr** r..'.<.*.*,=ai s.~~'=..'.~=.,~u.~*cy

' 609 339-346J 92 08 25 a

s n

o so Hope Creek Operations

'n*o s~t i o i,',,..,....,a-...'.~,=,n.,..,=,.~

S.4,J,.

'E

~

t

>= ae - -a saa > usc *>

>a o PR C.,a E,, cuy,,E TVPED OR PRINTED

    • d'""*************""'*'"*#""88**""''*'****di***'**

OF83 R AU HOR ED AGEN f

_^ ^

NUMggR YEAR

n. O day CQQE

'r COMMENT AND EXPL ANATION OP ANY W80L AY tONas 4 Referews off a,stw heraers erre, EPA Form 33201 (Rev.9-88) PinMous edirlons ma$

g aoreruseo L,,8,J g I_7_451

?_/5[ Q 643J O

ease 7 oP y

P2nustre :t asamaziacoeces /hefude navsomat *ottuvaser oesc aeca euw,=aveo= e.srew iAPvfL '

Fenhap Nam u/Locarba 4(4'fferent)

DCCH AR*E MONITORIN3 CEPORT FDW1 BAMI- _ E SE EG __ __ _ _ _ _ _ _- _ _

(2 161

/iIt o' Form Approved.

      • 7:n

_._EnIla BDK_2M/1271L _ _ _ _ _ ___ -

NJ0325411 462A OM8 No.,2c40-oood.

_ ___ __11ANGGS__RMDGk.,MLOe0_3a__ _ __._ _

Approval empires 6-30-91.

Eauirau=*==

NORTH STORM DRAIN MONITORING PERIOD I

4AJCR SALEM J.Ac.Lu_Iy _ __ES.EEG_MQgE__ GEEK _GENER ATING ST

,h

$i-SOUTHcRN REGION C

  • ao=

92 0,

G1"

_LQWEg, ALLQMAJS_,,.QEg,NJ_08038 ro 32 Locat:0+:

TMR Nt!MBER* 92070486 r2o m <nni (24 257 s;en as2w inm NOTE: Read instructions twfore completing tNs form.

(J Card Only) QU ANTITY OR LOAD 4NG (4 Card Only )

QU ALeTV OR CONCf hTR ATION

      • W'**C' da E

PA R AM ET ER (46 53)

(3441)

(1845)

(46-53)

(3447)

O p,

,g []((

X m m XX XXLGEMuiF.XX unns XXMMKXXXX XX% m XXN XXXM M XX unn.

,,3, PH wEa.,LE 7.1 7.1 0

1/mo Grab uREuf=T 004CO 1 0

' eEnu it '.

        • 6 00MNt 9 0M U

ONCE/ GRAB EFFLUENT GROSS VALUE

        • RINIfRNt MAXIfteM NONTM SOLIDS, TOTAL 111 111 1/mo hab

...n,

"'**""*"*ur SUSPENDED

  1. 99888 REPORT

'l REFUKT MG/L ONCET'GnK4-00530 1 1 (ADMIN)

. rEnvir--

EFFLUENT GROSS WALUE

> ~

~

MNTH AUS 3LY MAX MNNTg8 HYDROCARBONS,IN H20,

.. n E

<0.10

<1 0

1/mo Grab.

""^*""*"*"'

2DgCC14 EXT. CHROMAT 03551 10

+******

REPDMT 157449% C MG/L GNCE/ salAh.$

,E.w ir EFFLUENT GROSS WALU' MNTH AWG BLY MAX MONTel l

. unE CARBON, TOT ORGANIC 5

5 0

1/mo' Grab (TOC) 1******

REPORT

$0T98WWW-MG/L ONCE7~GRAa~

006C0 1 1 rE w ir -

EFFLUENT GROSS.WALUE "h

MNTH AUG.

DLY MAX NENITN FLONo IN CONDUIT OR O.,0 0.20 1/mo

...,L E

"'^*""'"*"'

IHRU TREATMENT PLANT 50050 1 O r,E.w iT

' REPORT-REPORT-

~88W68*

  • 4F4F6
  • W66**

co*e agCE'I EFFLUENT GROSS VALUE * * '""'"5 NET 94 AUG ' t SLV' MAXI - MGD NONTel S AM PLE 1

MEASUREMENT

  • PERU fT R ESUt REM EN T.

S AM PLE MEASUREMENT

~ rE=w er itEQUtRtM ENT NAte2/ TITLE PRINCIPAL EXECUTIVE OFFICg.

6 m a v u ot e et vy Cs a.

T.e.T f pe nst t v e s.

o 3,,.L E PHONE DATE o',.".

~v e' a~s ce.'.*na.*e *.~. ~er i a. <.<. e. s.ee. rve.o'"., o '.,"w

' ~ ~ " " ~ * ~*-

a. Hagan om..m. c.wo...,..,,, Eo_a,u o

.s.<..

m cenera1 Manager o.

m.

. m s, o

._ liope Crcck_Qp.crat_ ions

',** ",^"." ' l," ',, '"", """,'**,7.,f",,,l," ",'s, *,,"l"', "d :

M }j womesR 609 339-346: 92 00 25 sou=>dRt e en cien oEcuTive o

vvno O.,R,uTro

.,.--..<a....-a...<~....

o,, k OR au worn.

astur vE n:

uO o.,

'31NW1'L*'i itf'TP "YA R'E N"DUR ING'* A"'llTSCH A R EE'" WWE NT, EXCEPT F0Ft PET HC FOR kHIC D AMPLES SHALL BE TAKEN DUIilNG~~

i THE 1ST PHECIFITATION-EVENT OF MONTH WHICf! c Ucr.~

UTSCHARGE a1URIt.'G WGRK ING HRS C IS PR 8' C E D E D BY MINIMUM l

DRY PEFIOD OF 72 HRS.

  • Ua*Ne 'o " "' 58mP at " *

' "' rfui m(arta danas rn mal wrLing hours was not king enough for Jumen and 45 men sampics.

h EPA Form 33201 (Rev.9-88) Previous oderions snay t,e un g8153 17451 77535 06431 easa or

. -

  • v.sor a use o i 8

12 u

pe#taarvan maus: ApoRess #adede

=.vio a t cou ve. e o.sc

.ms,e e o=,= a v.o= se s, a ma c VOLL Feessay Neune/Locesa>= 44fferra'l DISCH ARGE MONITORING REPCRT -D*r80

(;.G., _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

um n7&

Form Appro-G neg_

P

_f._D.,RDX_;iU6/N21 NJOO25411 462B OMB tb 2040-0004.

A noRees Approut emp res 6-30 9L eeRuir aum==a

- ----c.---..-

_.__._ _____BahCOGS__BRLDiiE,NJ 080 38

] MAJCR SALEM f_______-------------

MONITORING PERIOD PS(EG HOPE CREEK GENERATING ST y

l racion rao= -9 b4b SOUTHcRN RE6ICN tocarOa LOWER ALLOWAYS CREEgNJ_0 8038__

ro l

l DMR NUMBER: 92070486 av2o a2 zo ad v cm T.CFTsEJTi NOTE: Reed estrinctsons before completmg this form.

( I t ard Only )

QU AN TIT V OR LO A DING 44 (ord Delti QU ALSTV OR COP *C E N I R A T ION

('**

'*AM M

P A R A n.* ET E R (46-J f )

13441) ifA49p 4 46.J f )

(344f)

  • O XkY.,buKXN XXMX.AXXM X).XhuxXN un

^ ['[,

("

\\

V4V6EMXXX XX.Xin N XX uneTo j

\\

BOD, 5-DAY

  • ^ " " ' '

52.3 M.3 384 384 Um W2

""^*""""'"'

(20 DEG. C)

REPORT

'REN5RT KG/

REPORT REPDAT R MG/L DNCE7~ERAF-00310 G 0 p

un RAW SEW / INFLUENT

"""'""""' MNTH AWG SLY: MAX $

DAY MNTH AVG DLY MAX MONTM

! O Vmo Gmb

" "^

  • u"e't u'eu r l.2 1.M 9

9 BOD, 5-DAY

  • ^ '

(20 DEG. C) 00310 1 0 naurr : 6.SMSgt

_ RETIliT -

KG/

REPORT MPCRT jMG/L UNCE7 EAAB-~

"'*'"""'"' MNYWiAVE - SLYEMAX' ' DAY 7elTH AVG DLY MAX

{

MONTH l

EFFLUENT GROSS VALUE i

l0 2/wk.

Grch 6.2 7.4 j

PH

,,,.A"Eu'eu,

u

            • ~
        • E.ODeet M#***

9;05 N F R Su THICEFERAR-

~

00400 1 0 nou ir

^

        • MINIMUM MAXIMUM l

' ~~T 1

NEEK1 EFFLUENT GROSS VALUE SQL IDS, TOTAL 826 826 1/mo Comp

""^* * "'"'

SUSPENDED M

        • ~64*M5 KEFORT REPuMI MG/L DMCE7 COAPSb 00530 G 0 nnuir.

RAW SEW / INFLUENT MNTH AVG DLY MAX MINITM MMIC 19 19 0

1/mo Comp SOLIDS, TOTAL

,,,,a

""^*""""*"'

SUSPENDED

        • ~~4fe #W*

30;55555'~~ IDCieweet MG/L UNCE7 CUpr55 00530 10 esnu ir MCITH AVG BLY MA-4 MEMf7M EFFLUENT GROSS VALUE

          • e 6

0 1/mo Grab DIL AND GREASE o

  • *= Pu

""^.ume=Euf FREON EXTR-GRAW MET 0

        • N4M6 10;essee 15.seeee MG/L ussces timMs -

00556 10 nnu n

! ' '~

MNTH~ AVG BLY MAX MONT98

"""'"""W EFrLUENT GROSS VALUE

        • N Daily Floin4 FLOW, IN CONDUIT OR

...,u 0.032 0.047 l

THRU TREATMENT PLANT 50050 1 0

- nnuir

. REPORT!.

. REPORT -

N T###

    • M ##
        • U BAILY FLuissu EFFLUENT GROSS VALUE "'"'"""" )HffM AWS n SLY i MAX -

MED

,.ur o e o,r, nauamru rRiucicAt anscuriva OrriceR

.,cj ; ;,g-oe= gtg oj.a=,,v,-ar g t,, g agv; g o

- ~~ ~

r-

<a

-.ou ~ o, v.<se at va,*i s - r

  • n t. ans,<-sa i ".

J.

Hagan OffT assesesG V Wet sesf OpuA Ts0 g E Sbf 4It vi f att StEbne11iD pd QNas A T af Jes,

,s e-ue *maan

~o e-in. *-

-<<-><-e.

-. sv General Manager

./'

" 7'I'O. 'T.~%'f' "1.# s*7* %", o' T. 7d,P.~.<~'.

609 339-346J 92 08 25 Hope Creek Operations _ _ _.

ad*******'"'N'**"**""'"'""**'"'"'"*'""**d*

1.

~ u

>+

.~c

' ucurewe

.., s.s

...,,., _...,....,. ~...,.,.,.,.

A A

OF M OR UTMO t2LU.GENf NuMNtR YEAR MO DAY Yy *ED OR PR8NTEO

' WWd@Mfef"cBT f/ Wit *f6Y"ce6W"Unainef 7/*12 and 7/26.

.. m a r =o r.e use o e 09153 1745]

7753j __OM 31

,.ce o,

EPA form 3320-1 (Rev. 9-48) Previous editions mad 12 y,

N av so**= s *ouu v A=v oesc -a nse r u== = a vio s sis aa MDE3i pennestres P AMassoomass (Juh.de Dt'LCH AGGC MONITOCENG REFORY :DetR) featary Neme/Lors:kn tf &fferent)

U te!

Form Approved.

tsA"Jr-- _ESE LG ---- __ - - - -,_. ___ _ __

  • *
  • r **___ _E.D _.aD E 2 3 6/N2L_ __ ___ __ _ __ _

NJ0025411

%2B l

OMB No. 2040-0004.

=+ -- a r.< ~ ~* a l Approva! expass 6-30-9L

  • * * "' r a u " ** n

_ __ _ __HANCDCKS_ BRIDGE,NJ_08Q36_______

MONITORING PERIOD MAJOR SALEM

- - _ _ _ _ - ~ - - ~ ~ ~

f_ ACLU _Tv__.,f5f gfa_BQEE_(RE EK f,ENER ATING ST

,,,,, ;,, YMi~

vo 4

D

,$1-SOUTHWN REGICrv

_LDMER_ALLQM MS CREE,NJ 08038 52l G

  • ao*

t.ec areO" DMR NUMBER: 92070486 av 2n al.w a< n, a6a, cg #7JJ UT NOTE: Read instructeons befora completing thes form.

/

(1 Card Defy) QU ANTITY OR 1.OADING u ( sed Only )

QU AL* T y OR CONCE N T R A T ION

{;N

  • "'"l '*

s*,,y*

(g *7"""',,, " '.,,,

/

m ss>

< sa >

vus >

us.ss a

usur, rrRAuETER x m m xx x m m xx xmwxW
oNu,

("-">

xu m axx xuwwxx UNu.

,m, COLIFORM, FECAL

.AMeet

<1

<1 0

1/mo Grab measure =ENT

/100 DECETRR W GENERAL 2W"POG* g

L MONTii'dED NKLY SED M

MONTH

{

74055 10 vgRu uT "800'"5" E"Y EFFLUENT GROSS VALUE i

BODp S-DAY PERCENT

. A M,L, 97.6 97.6 0

1/mo Calc

"'**""'"ENT 81010 K 0

- eERM er-

        • 67 5999&

REPORY

  • *WM PERCE GMCET CKCTl>

REMOVAL "E " "'"'"'

~

        • MONAVRIN EVERAGE NT MONTH PERCENTREMOVAL SOLIDS, SUSPENDED

.AMetE

=EAsuRE=mf 98 98 0

1/mo Calc PERCENT REMOVAL

~~TfDKT

    • s*6*

PERCE CNCE/ CACCT1l

~

R 81011 K 0 eERuir A5.ggggtt-

"* * *EME"Y

        • MONAWMIN AVERAGE NT MONTH PEC!CENTREMOVAL DXYGEN DEMAND

. AMet E

""^*""'"'"'

1.5 1.47 10.8 10.8 0

1/mo Cale

{

82210 1 0 PERU ir 8 2M

. PEPORT --

KG/

REPDRT MPORT MG/L UtiCET CACCM l

FIRST STAGE f

EFFLUENT GROSS VALUE RNTH - AUG' BLY MAX'-

DAY MNTH AVG DLY MAX MONTH S AM PLE MEASUREMENT PERMIT REQUIREM ENT.

. A M PLE MEASUREMENT

' PERMIT REauiREw sNr

. AM et E MEAGUREMENT f

PER W IT R EQUIR EM EN r e

m s't (Tv

(

Tw i

e nn tv see s o TEL EPHONE DA 7E NAME/ TITLE PHINCIPAL EXECUYlvE OFFICER a]

.w w. fSE SM[SPOpe$a g t..F Me OF veef aNL3Wstasat S aheme([mAf f t y Des esv spe(JusRv

%st, /

no.. an = ve ~ SoM.vvi o==

oevaa. 1-r J.

IIagan t Gh it Af f t,fRA rf A.gO COnerg f f t e 4 44 Amapf VMAY T Mi set sauf

~<-

  • ~s

~ wr.

General Manager

~ ~*o e s.e m...o 75

,e

~ o,,,-* u -

6Q339-3463 9 2.

.08.

25 u

su ust

..o0, 55"*"

E'

'P^'

"E(""vE

.~w...m, r u.

s.

.*~.,.,.... a i. ~ n.....

m.m Jope_ crock _OpRtNTEDe r a t a..o n s _ -.

  • d"'aad********7"*'**'""*d6'****""**'"-**d'"***'

of F st M AU ORill AGENT NUMBER VEAR MO DAW T\\ PED OR COM M E N T A ND E X PL A N A T ION OF A N Y V 90t A f 00N S ( Nrferr#8Ef ull esten hautessi s #Drrr )

ease or EPA Fo#m 3320-1 (Rev. 9-88) Provsous editions may be usmf.

i.*a rt Ac ts se A conM v-se m.mc.N M A v No r er usEo 081S3 17451 77J3*5 _OfAQL 10 12 LABS:

- Paesestvas manes, ADDRESS ffsclesdt.

Mateosi at roLLuv anv eesc e* A#GE EL****** &Yeost s y sts**, Al'Df 51 Ferdatp Wom/locasins iforfferenal DIT, CHARGE MONITOQlNG MEPORT <D4fK1 IRAtl.5__ fifna (1 161 (17191 Form Approved.

=

e.o o m as,_. l n g e_. J D K _ 2 3 6 f M 2 L _ _ _ _ _ _ _ '

NJOO25*s11 463A OMB No. 20404004.

l __ ___HMC0CES.3RLD6f *MJ__Oso_38_ _._ __

E = =ir au=== si -

= - -

Appvovat empires 6-30-9L t

SOUTH STORM DRAIN.

1


~~~~~

MONITORING PERIOD 5*b'5".lifl;&_ HOPE CR8EEK GENERATING STLQWE8_.AL103A35[CMEndO]O'_38((

racsurv MAJOR

' SALEM-I'M W db M-D 1

SOUTHERN REGIOh rao=

10 DMR NUMBER?. 92070486 ao 2i, ar2w n4 25, a -27s,20, isS>i, NOTE: Eead iratructioens before completaris this foem-l N

O can o *n au su n sv On tonD,~a v cas o.sn ovata, On concnnsnanOn n,,

n,v on,,

g

,,-l.. y A...E,E.

l'* "'

^ ~ ^';

xxxmeoe<xx xxxN m xx u-n.

yxu,x m xx xxxwxxxxp xxx m xxx m.n..

eH uE'.u"iTEw'im 7.7 7.7 0

1/mo Grab 1

004C0 10

'**** Ehs, 3.OPRt SU

_-__a# Emmu U

        • EIMENUR~

MAX 1/.asM MMT88 EFFLUENT GROSS VALUE " " * " ' * * " " " ' -

a n

SOLIDS, TOTAL

...,,tE SUSPENDED

"*^*""*"*"r

. 116 116 1/mo Grab 00530 l'1 (ADMik).

Y Y

.lI N D

    • 3*

4'

        • 7: 2995-REPORT.

REPURT MG/L GECE# IERAB l

99980 %

i ::::.:

,,....r u

EFFLUENT GROSS VALUE MNTH AVG-DLV MAXe AM HYDROCARBONS,IN H20s

...,t g IR,CC14 EXT. CHROMAT "E^*""*"*"'

<0.10

<1 0

1/mo- ' Grab.

s <== r,

-L

- :::f:

REFORT-~~1N-MG/L smCE7 M1,

00551 1 0 e

M fMTS AWG' BLY' MAX mmT86

  • , +

EFFLUENT GROSS V4LUE CARBON, TOT ORGANIC

... Pt f 36 36 0

1/mo Grab (TOC)

""^*".".E"*"'..: ::::

~~

REPORT 54h MG/L ussa.ms 6 00680 1 1

,E

,y ;

EFFLUENT GROSS VALUE NNTH AUGT DLY MAX 3 3 1788 FLOW, IN CONDUIT OR

    • 464*

e6T54s i

" '^.u"n"Eu"a u r 0.22 0.22 1/mo-

  • ^ '

THRU TREATMENT PLANT 50050 10

.L,,,. r.

REFWRT 4
REgesen U

~59888*-

454###

usen.t/

EFFLUEhT GRO5S VALUE,""****"""E Mfgl

  • AWS ' SLY) OthX 4 - MGD HMflg i

S AM PtE MEA 9UREMENT l

PERM lT kk['

f ese.,usasse. sNr.

m sawetE

+

MEASUREMENT f Peemst '

~

aseuensuswr p

4 NAME/ TITLE PRINCIPAL EXECUTlvE OFFBCER 4 centss y uovoEm peeativ Cw t aas tesa t a Mavt eg asos.at e na sw D spd opsuaT40se hugeeTTE D ME nt m.ty TELEPHONE DAYE ANO AM F AmeUAR wpTM T eeg aasO ta5ED J*

Haaan Otsf a"sp'eepst, "T*4E

"' "msF OIDMA f sO4'"o" "* * "* * 'u"an'er FTE D to.p osteina v"aose 7,

a s

i Sit 4 WR THE S s

j j

ceneral Mana9er

' "-r ".e"o"a..". c., c= "..'.~c'.~m~s, ~.e., _'-..~.o.e~ m~e..~u q

a so

~

l Hope Creek Operations

',"'o.",M*ll',' Z,,';"', ^2 "*",C',,,,5",ja, up1,*,"y;,,?

ntn= Ec o nv E 609 339-346] 92 08 25

. ~ uE P.,

rYPED OR PfttNTED

    • '8*"******'****'P""**"***'#"**'****""#4***#6***'**

I!I ^

Op 04 AUT ORIZE '

AGENS NUMBER YEAR

  1. 80 DAT a5MMPEt*5" YUfM'"?AR'E4P'DURUIG5 A*DTscMAmeE~eWENT, EXC E PT FGR PET HC~ TOR ~WHT MPEES-MLL-EE TAKEN EURING-~~

THE IST PRECIPITATION EVENT OF ' MONTH MHICH C AUSES DISCHARGE LURING hiORKING HRS C IS - Pua-CEDED BY MIhIMUM

'I DR Y PER10 D OF 72 HRS. *UaaNe to meer samphng crucch a a m m ma a.norge event ihai occured dunne normat =ortmg t =rs was noe sons enough for 3rnma and 45mm sampics.

EPA Form 332M (Rev. 9 44) Prowdous editions may be used.

gggas aea eowu v-se _w

.c_

= a v mor en_use o.:_ GfsJ 53 L2.ML.22515. 06ill y y o' 12 i

easu

n a veon a t cot tu v a v o.sc = a n c.a s o=.m r eo = s < s v a = rVDE L

  • smuntras mauss Aposenes (Imetaure Dl&CH ARGE MQNITOHING QEPCRY DWRi Tecday Neasa/Locarba (f &/farr.cf o-ro!

97'*

Form Approved.

etants _ _._ _P SE EG __.____ _ _ _ _ ___ _ _ ___ __._ _

NJ2023411 464A oug r30. 204o. coo 4.

__Enfe_HDK_236/.N21_ _ _ _ _ ___

Approvat expires 6-30-9L

^* " :'*

""""u"***

_ _ _____HARCDCKS_RRIRGE,NJ_08038_ _ _ __

PERIM STORM DRAIN y o ngy o pgy a pg p,o;,-

SALEM MAJOR

-d;71] SOUTHEM REGION f._^ ctu_r._y___csig_.gogg.lREEKJENER ATING ST Oi Ol~

'o

_LQNEp _ALLOM&YS_ CREE,MJ _ 0 6 Q 3 4__ _

aolo a12* de &

usJo Je 1*<

'AT M NOTE: Read instructeorts before completing this form.

e.cc Ar sOa DNR NUMBERt 92070486 U Card U=JH t.wawTary on LoADiNo to Co.d onto ov4Leiv ce cONCEavraation

  1. AMPL' Os (46 31)

(34 4f 4 14449)

(d6 33)

(3441)

XmKWXXXXV.xxxxXdXXXmEXhu~is.

b, ^ ',,',$ '

PARAMErgM x

[N x m toaxxx xx m wXX u~ ire

("'

i 7.2 7.2

}

O 1/mo Grab PH

.,__E wEasunEwEnr e'W4T44 9.D

~

}SU UNCET MKh-6.

l MONTH 00400 10 cenw sy MAK EFFLUENT GROSS VALUE

        • MIN
  • "#8 M*#8
  • ""8

. A.,,,t E 42 42 1/mo Grab SOLIDS, TOTAL MEAwarMrar 86

        • 7D*H RPDAT RPORT~-~~ M6/L

~WE GRA F SUSPENDED 00530 1 1 (ADMIN)

  • E n u ir EFFLUENT GROSS VALUE

~

f MNTH AVG DLY MAX MONTH

.. rt E

<0.10

<1 0

1/mo Grab

  • HYDROCARBONS,IN H20, * * ^ " " ' " ' " '

'*O****

REFonT iSTQQi@lAlf~ MG/L OKETGMAB%

~

IRoCC14 EXT. CHROMAT MNTH AVG DLY MAK MONTH 00551 1 0

  • E n v ir EFFLUENT GROSS VALUE

~~

49****

CARBON, TOT ORGANIC

...,c, 17 17 0

1/mo Grab WW****

REPURT Mg7MG/L

-DhCE7 GRAB-(TOC) 00680 1 1

,E

. r MNTH AVG DLY MAK l

MONTH EFFLUENT GROSS VALUE

        • 60

"'^*""*"'"'

O.28 0.28 1/mo FLOW, IN CONDUIT OR

...m.

THku TREATMENT PLANT TWRT*

M* *

  • W
        1. M UNCEI

' REPORT-REPORT ~

MONTH 50050 10

,En u ir

" " * * * * " ' " ' - NNTH AVG BLY ' MAX '

MGD EFFLUENT GROSS VALUE S A M PL E MEASUREMENT PERMIT REQWnENENT

. _ _ ~ _.

6 A M PL E MEASUREMENr JPEnw ir R EQUIREM KN T TELEPHONE DATE Et PT Liv L

6 af Avf #f att y A

N AME/TirLE PalNClPA4. EEE4 JTIVE OFFICER v,

i

u...

oe y e.

~,_ s - m.....

s.o s.,, m.

sue.-ri o t h(~ o. <x 1

. nu m. A.M e->.

c.

v~e

~ m

.o.

J.

Hagan T.eA T 1 A

g r,

&& A (

sh F 8.UE M fD a.g am.D {l{jempg f Tg

..so.~ r,<

.i,seu o..o u-~.~.u.u.

~

.o

, ~2 a.-vn ~=o n. + =

General Manager Jiope_ Crock.OperatJ.Ons-

~ -...--_.~~.e..

a -- w..e n.. v. i,.

u. s r....

"",^',c" '.,",',,'o,' o w,,,"* 6 Qp, 3 3 9 - 3 4 6 '1 9 2

. 08-2S

~ u.

...o nvu*..m auM=a= ] vE.=

m e-

.*~.... -.. n 1

o.,

mo o,

'dW MI'l'l*5" itI"#@"1* WEN" 00RTNG'* A"'11T5fft AR GE* 1*V E N T, EXCEPT FOR PET HC FOR WHb W SAMPLES SHALL

,v e.o o eneuyEo DURING WGHKIhG H't5 E IS PRECEDED BY MIh1FUM PRECIPITATION EVENT OF MONTH WHICH CAUSES DISCHARGE THE IST 72 HRS.

  • UnaNe to meci sampling enteru due to the sole dixharge event that <stured dunng normal wwLng hours was not long enough for 'lomm and 45rmn samples DHY P t-HI O D OF eum or e eg*ces eea e on s T-as =necee =_a v e.c r ma osao sy 17 4 <{]

77c;3( _nca g EPA Form 33201 (Rev. 9-88) Preveus editions may be used.

t

______