' g3yg/3y - c/ V/0 APCo Exhibit i19 M12.12 Material Safety Data Sheet
(/ 2_,
tJ.S. Department of Labor;iii May be used to compPy with Occucationel Safety and Health' At! ENstration OSHA's Ha.tard Commufwcation Standard, (Non. Mandatory Form)
\\
H CFR 1910.1200. Statyjard must to Form Appro.ed umuned for speerhc requirements.
OMB No.1218 0072 '92 JUN -2 P12 :0h tOOq (As Used at tabet aM Uso thre SwA space a:, not pumma. I any nem is tw atxscabw w m CHICO A Sealino comtmind
- rmaaran a em m apeo(mst to metid m ems iney,,,
Secte i
"" $ ;,k,/ ilh5$ Huard P.ati! l Marvaawrer e Name t.r%rgency lowpnone Nm Healtha 3 Minimal Crouse-Hinds ECM Div. Cooper Industries 11 % /d 7 7-7nnn Aooma (N. mew, Lewr, ca, sta% and i/P owe)
Treptiuns Numour s r informacon Flamm 2 Llity: 0 Min l r
u l
l Hol f t, 7 th th rth S t s.
315/477-7000 R*8'Ct*VifY'OM2^18 om Preontec 10/86,3 /D7, P.O_._ Box 4999 6/87,9/87,2/88,2/8% 12/90, 1/01
&gnature of Preparer (opponat)
Syraeute, NY 13??1 Section 11 - Hazardous ingredients /ldentity information Omer Umru Harwoous Comccr+ms (Sc=n6e Cnemeal Identity. Commun Namats))
% (mra Aluminum Oxide CAS1344-28-1 15mg/m" Total long/m# Total 251 Calcium oxide CA51305-78-0 15mg/m" Total 10mq/m# Total 24%
rarric oxide CAsl309-37-1 15mg/m# Total 'lom0/m# Total 8%
3 7errous orida CAs1345
- >5-1 15me/m Total 10mq/m Total M
Silicon Dioxide CAG7631-86-9 15mg/m#'Ntal 10mg/m# Total 3g lite,:41um Dioxide CAS13463-67-7 15mg/m# Total lOmg/m# Total 2%
(All of the above components are ccebined as common names calcium aluminatesi calcium alumin'o 'farrites, calblum alumino silicates, and calcium titanate.)
Plaster of Paris CAS7778-18-9 10mg/m3 Smg/m3 (respirable) 2n 3
Portland Cement CAS65997-lS-1 10mg/m3 Smg/m (Respirable) 1%
All substances in Chico A Sealing Compound appear on the Toxic substance Control Act In-Section ill - Physical / Chemical Characteristics 0o4." Point SpectAc Grswr vi O - 1) i vapor Prosaure (mm No)
Mefung Poem N/A 1300 * -la !
Vapor Denasty (AIR = 1) bsparation Ra:e N/A (But$ Aceta's = 1)
N/A Sok6 tty m Water Neoliotble to 0.2%
- Appeararc.e and Ocor Licht gray, odorless powder Section IV - Fire and Explodon Hanrd Data Flash Point (Memoc usec) f tammarme Umrts LEL UEL.
MONE N/A Estoguraning und.a Not combustible C
Special Fro Fighung Procedurers Nono unusuai r,,.m en.n.,i nawa None 9207310146 920518 PDR ADDCK 05000348 G
.~
. ~ -. -
~
11AR-31 '92 TUE 09:3-1 ID:C-H ECM EASTERN REG TEL tot 315 47? 5179 a635 P03
~*
' 0'P1313
- s. coon v - n eway Det.
Satsy Unsatse conomons to Avoid None Sabee X
i thcompatibility (W4fortels to Arodtf)
_None Hazankxa Omanrvyosen a f>yprvoutxa Above 1450 C - 50, & Cao Nazarocus May Occur Corontons to Avoed fvymervaern WJ Hot Cbcur X
Section VI - Heetth Hazard Data fWus) et Erry' trMmm? -
SkJo?
tegeston?
X X
y Health Ha24tos (Acus arty Ctrtruc)
Acute:
See below Chronie:
None known Carorv9e* #
NTf'?
lAAC Munogra.T.a?
OSMA Re;punec7 Sagas and Symptoms a F;goeure over r.wposure may cause irritation of eves and skin.
Mav develop sufficient heat to cause burns to a large Skin mass if Xept in contact while hardening takes. place.
YphalatiCrQ duct i t' con 9iderad a nui9mnce dutt with a TLV of 10 to/m3 total, or 5 mg/m3 respirable.
Emer?ency &nd F4 AC Procedarse sealing compound hardends when wetted and_if ingested results in obstruction -(hardeninc irritar36n continues,iate1ghvste}. '!.
flood immed for timeis2{-20 minutes)em,eeppyemspA_bvwaspno,feyecontact s
sici In ca o
,-4 -ene w th water, ve 1
s>ee i.
SectJon Vil - Precautions for Safe Handling and Use -
l Stocs to Be Taken in Casa Malena!Ifww or Splio1 vacuun where possible, or sween uo.
Avoid creating excessive dust.
Material will harc
._in presence of water and may cluc drains.
- Waste Disposal Metrud Best convenient method in accordance with Local, state, and Federal reculations.
Precavuons to Be Taken in Handling and Storing Store under dry conditionc.
Dew point conditions or other Vet conditions during storas will harden sealing compound.
Other Precauuons None Section Vill - Control Measures RewraWy Protecuon (Specty Two)
__ NIOSM anoroved nuisance duse repirator if aMve TLV (in very dusty conditior s) vomtaten t oca! P.xhaust SpocaT.
Vem if above *tv Meenarucal(Genere!)
omer outdoor conditions Protectrve Guves Eye Protecten War c1nvec 4 f rin c t nr ninrry in irritatine Dust coqqles if dust is annoying Other Pettoctr4 Clottung et Equ@mont I
t
.-.4...
.