ML20117J984

From kanterella
Jump to navigation Jump to search
Forwards Results of Drag Tests Conducted in Spent Fuel Pool Following Cycle 6,per NRC Bulletin 96-001
ML20117J984
Person / Time
Site: Vogtle 
Issue date: 09/04/1996
From: Woodward J
GEORGIA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-96-001, IEB-96-1, LCV-0788-D, LCV-788-D, NUDOCS 9609110068
Download: ML20117J984 (3)


Text

-c

.. ~..

' Georgia Power Company 333 Piedmont Avenue l

Attanta, Georgia 30308 Telephone 404 526-3195 Ma: ling Address 40 invern. ass Center Parkway Post Omce Box 1295 Strmingham, Alabama 35201 Telephone 205 868-5086 J. D. Woodard the sournem ewtrc system Senior Vice President September 4, 1996 LCV-0788-D Docket Nos. 50-424 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:

VOGTLE ELECTRIC GENERATING PLANT DRAG TEST DATA FOR UNIT 1 CYCLE 6 The results of RCCA drag tests conducted in the spent fuel pool following cycle 6 of l

Vogtle Electric Generating Plant Unit I are attached. This data supplements our response to NRC Bulletin 96-01 transmitted with our letter LCV-0788 dated April 4,1996.

Sincerely, k'

J.

. Woodard l

JDW/HWM/gmb cc: Georgia Power Comnany Mr. J. B. Beasley, Jr.

Mr. M. Sheibani NORMS U. S. Nuclear Regulatory Commission L.b }

Mr. S. D. Ebneter, Regional Administrator Mr. L. L Wheeler, Licensing Project Manager, NRR Mr. C. R. Ogle, Senior Resident Inspector, Vogtle h

(

l

}

9609110068 960904 PDR ADOCK 05000424 G

PDR

Q F/A Last S.O.

  1. ofInactive F/A Burnup F/A Fast Withdrawal Insertion Drag ID Cycle Code Cycles (MWD /MTU)

Fluence Drag (Ibs.)

(lbs.)

2i (x 10 m1)

Dashpot Upper Dashpot Upper himble Thimble 5G01 6

GAEF 0

42390.3 7.35 35 8

40 10 SG02 6

GAEF 0

42381.8 7.35 25 5

35 10 SG03 6

GAEF 0

42551.5 7.35 50 6

60 10 SG04 6

GAEF 0

42524.4 7.35 40 0

40 5

5G40 6

GAEF 0

41623.9 7.2 45 0

45 5

SG41 6

GAEF 0

41223.2 7.12 40 5

40 10 SG43 6

GAEF 0

40728.8 7.02 35 5

40 10 5G44 6

GAEF 0

41631.8 7.2 35 4

45 10 SG47 6

GAEF 0

41177.9 7.11 25 0

30 5

5G48 6

GAEF 0

41159.9 7.11 15 0

25 5

5G50 t,

GAEF 0

41129.6 7.1 15 0

35 5

SG52 6

GAEF 0

41502.7 7.17 32 3

40 10 SG55 6

GAEF 0

49493 8.81 40 0

45 5

5G56 6

GAEF 0

48908.7 8.68 40 0

45 5

SG58 6

GAEF 0

49406.2 8.79 30 0

40 5

5G63 6

GAEF 0

49270.3 8.76 50 2

50 5

5G67 6

GAEF 0

50851.5 9.09 185 7

125 10 SG70 6

GAEF 0

50585.9 9.04 95 13 80 17 SG80 6

GAEF 0

50805.2 9.08 175 6

145 10 SG82 6

GAEF 0

50677.3 9.05 65 5

65 8

5H01 6

GAFF 0

25944 4.23 10 0

15 5

5H02 6

GAFF 0

25716 4.19 10 0

20 5

5H03 6

GAFF 0

25823.6 4.21 15 0

20 5

5H04 6

GAFF 0

25828.1 4.21 14 0

19 5

5H05 6

GAFF i 0

27923.4 4.59 30 0

35 5

5H06 6

GAFF a 0

28251.7 4.65 50 0

65 5

5H07 6

GAFF 0

27993.9 4.6 25 0

30 5

5H08 6

GAFF 0

28035.9 4.61 15 0

20 5

5H09 6

GAFF 0

27842.3 4.57 40 0

50 5

5H10 6

GAFF 0

27817.6 4.57 10 0

15 5

5HI1 6

GAFF 0

28125.3 4.62 30 0

35 5

5H12 6

GAFF 0

28350.9 4.66 45 2

55 5

5H13 6

GAFF 0

27928.3 4.59 15 0

20 5

5H26 6

GAFF 0

26864,6 4.21 10 0

20 5

5H28 6

GAFF 0

26601.1 4.35 20 0

25 5

5H38 6

GAFF 0

26800.7 4.38 20 4

23 7

5H39 6

GAFF 0

26177.1 4.27 20 0

30 5

$H40 6

GAFF 0

26069.7 4.25 20 0

25 5

5H42 6

GAFF 0

26465.1 4.32 25 0

25 5

5H43 6

GAFF 0

27256.3 4.46 15 0

20 5

5H44 6

GAFF 0

26290.9 4.29 10 0

15 5

SH52 6

GAFF 0

29326 4.84 25 0

35 5

1

~-

I i

l F/A Last S.O.

  1. of F/A Burnup F/A Fast Withdrawal Insertion Drag ID Cycle Code inactive (MWD /MTU)

Fluence Drag (lbs.)

(Ibs.)

2i Cycles (x 10 nyt)

Dashpot Upper Dashpot Upper Thimble nimble 5H53 6

GAFF 0

28630.8 4.71 25 0

35 5

5H54 6

GAFF 0

28927.7 4.77 35 5

40 5

5115 7 6

GAFF 0

27677.7 4.54 20 0

20 5

5H59 6

GAFF 0

28924.3 4.77 35 0

40 5

5H63 6

GAFF 0

28851.9 4.76 30 5

35 5

5H64 6

GAFF 0

27795 4.56 30 0

37 5

5H71 6

GAFF 0

27562.7 4.52 25 0

35 5

5H73 6

GAFF 0

28977.2 4.78 40 0

50 5

5H75 6

GAFF 0

30270.4 5.02 25 0

30 5

5H77 6

GAFF 0

29183.2 4.82 25 2

27 5

5H81 6

OAFF 0

27637.8 4.53 25 5

30 10 l

I I

(

\\

I i

i i

-.