.. _

t Pacific Northwest National Laboratory Operated by Batteile for the U.S. Depa. ment of Energy 1

i

~

i I

~

go-4' ?'I, 4 4 Y l

March 26, 1996 i

E. Harold Gray US Nuclear Regulatory Commission Region I 475 Allendale Road l

King of Prussia, PA 19406 j

Dear Harold:

Subject:

JCN 2126.

Task 4.

Manual and Automated Procedure for Ultrasonic Examination of Centrifuga11y Stainless Steel using Low Frequency SAFT-UT System.

i l

The objective of Task 4 was to establish the feasibility of using the SAFT-UT System on cast stainless piping at the Seabrook Station. One of the l

deliverables for this task was a procedure for us'ng the SAFT-UT System in l

both automated and manual modes on cast stainless steel.

l Please find enclosed a copy of the procedure that we developed for use at the Seabrook Station.

Sincerely, N

l George J. Schuster Sr. Scientist j

Imaging / Nondestructive Evaluation

)

GJS:mb Enclosure DFD'S Yl i

2100G3

~

Mail Stop K5-26 Phone (509) 375-3913 Fax (509) 375-6497 4

l Battelle Boulevard a P.O. Box 999 e Richland,WA 99352 Sp &Cf y~

~ ~

Y, WOl/9004

$ bl/61l pyl_n

~

/[,

i a

,