ML20116N677

From kanterella
Jump to navigation Jump to search
Forwards Long-Term Pipe Support Insp & Evaluation Program Plan as Suppl to Jp Bayne to HR Denton.Program Plan Describes Complete Plan for Investigating Current Condition of Pipe Supports on safety-related Piping
ML20116N677
Person / Time
Site: FitzPatrick 
Issue date: 05/02/1985
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Vassallo D
Office of Nuclear Reactor Regulation
Shared Package
ML20116N679 List:
References
JPN-85-38, NUDOCS 8505070306
Download: ML20116N677 (1)


Text

123 Wn Street White Plains, New York 10601 -

914 681.6800 1

a "a">a'a a A NewYorkPbwer

!" *J O!% "*"'

tv Authority May 2, 1985 JPN-85-38 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr. Domenic B. Vassallo, Chief Operating Reactor Branch No. 2 Division of Licensing

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Long-Term Pipe Support Inspection and Evaltation Program

References:

1. NYPA letter, J. P. Bayne to H. R. Denton, dated January 20, 1984 (JPN-84-02).

Dear Sir:

This letter supplements the information provided in Reference 1 regarding the Authority's long-term pipe support inspection and evaluation program.

The program plan for this effort is included as Attachment No. 1 to this letter.

The program plan describes the complete plan for investigating the current condition of pipe supports on safety-related piping and assuring that these supports comply'with applicable installation criteria.

The plan also describes: the scope of the investigation; a program to repair or restore discrepant pipe supports; and, a program to document both the investigation and any corrective actions necessary.

The plan also includes a preliminary program schedule.

If you have any questions regarding this matter, please contact Mr. J. A. Gray, Jr. of my staff.

Very truly yours, J' -

ayn s

irst Exec 3tive Vice President s

Chief Operations Officer 0

cc:

U.S. Nuclear Regulatory Commission

]6 Office of the Resident Inspector Jg Post Office Box 136

\\

Lycoming, N.Y.

13093 L