Amend 188 to License DPR-49,revising TS by Incorporating Addl Reactor Water Cleanup Sys Leak Detection Instrumentation Requirements
ML20116M460
Person / Time
Site: Duane Arnold 
Issue date: 11/12/1992
From: Shiraki C
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20116M461 List:
References
NUDOCS 9211200285
Download: ML20116M460 (4)


Text

,

_. y l gM*svg %,

3 *'

UNITED STATES

  • 3 NUCLEAR REGULATORY COMMISSION o

WASHINoToN, D.C. 20805 10WA ELECTRIC LICHT AND POWER COMPANY

([NTRAL 10WA POWER COOPERATIVE LORN Bell POWER COOPERATIVE QQM.ET NO.30-331 DUANE ARNOLD ENERGY CENTER AMENDMENT T0 FACILITY OPERATING LICENSE Amendment No. 188 License No. OPR-49 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by lowa Electric Light and. Power Company, et al., dated April 22, 1992 and supplemented by another letter dated _ April 23, 1992, complies with the standards and requirements of the Atomic Energy Act of:1954, as amended (the-Act),

and the Commission's rules and regulations s'et forth in 10 CFR Chapter'l; B.

The facility will operate in conformity with the application, the provisions of the Act,-and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be-conducted-in compliance with the Commission's regulations;-

D.

The issuance of this amendment will not be inimical to the common defense and security nr to the health and safety;of the public; and E.

The: issuance of this amendment is in accordance with 10 CFR Part 51 l-of the Commission's regulations and all applicable requirements have.

l been satisfied._

L L

2.

Accordingly,-the license is amended by changes to the Technical:

L Specifications as indicated in the attachment to.this license amendment-and paragraph 2.C.(2).of facilit'y Operating License No. DPR-49_is hereby amended to read as follows:

4 V

i l;-

9211200285 921112 PDR ADOCK_OS000331T

, P; PI)R : *

=_- _ -

- - - =

1 1

l

.2-(2) Technical S a rlfj u ilqn The Technical Specifications contained in Appendix A, as revised through Amendment No.188, are hereby incorporated in the license, The licensee shall operate the facility in accordance with the Technical Specificationi.

3.

The license amendment is effective as of the date of issuance and shall be implemented within 30 days of the date of issuance.

FOR THE NUCLEAR RECVLATORY COMMISSION f

/ Clyde Y. Shiraki, Sr. Project Manager project Directorate !!!-3 Division of Reactor Projects lil/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance: November 12, 1992

ATTACHMENT TO LICENSE AMENDMENT NO.188 FACILITY OPERATING LICENSE NO. DPR-49 DOCKET NO. 50-331 Replace the following page of the Appendix A Technical Specifications with the enclosed page.

The revised areas are indicated by marginal lines.

LIST OF AFFECTED PAG 11 Rf)@lE MIERI 3.2-5a 3.2-Sa

an

.x

'M' TABLE 3.2-A EL S

INSTRUNENTATION THAT INITIATES PRIMARY CONTAINMENT ISOLATION (continced) 3.

2 Minimum No.-

Miraber of j [ ef Operable-Instrument g Instrument Channels Valve Groups.

1 m Channels Per Provided by Operated by Instrument Trip Level Setting-Design Signal Action (2)

Trip. System (1).

1.

Reactor Cleanup 130'F 3

5 D

Area Ambient High Temperature i

1 Reactor Cleanup A14'F

  • 3 5

D Area Differential

Highl Temperature w

su

/,, --

1 Reactor Cleanup

$111.5'F 2

5 D

j :*

Area:Near TIP L

Room Ambient l

High. Temperature 2

Loss'of. Main

- $10 in Hg Vacuum 4

1 B

Condensor Vacuum j

2

' Reactor Low-Low'

>+119.5" indicated 4

8 A

j water Level level.(3)

  • Note:

The actual setpoint shall be 14*F above the 100% operation ambient i

temperature conditions as determined by DAEC Plant Test Procedure.

p

=

~

..r,

- M~