HAWKEYE VALVE & FITTING CO.

O'*

1260 West 11th Street P. O. Box 319 Milan, Illinois 81264 kgN g PHONE: (309) 787 6800 FAX: (309)787-8198 SWAGE p companes October 22, 1992 Harry Johnson Iowa Electric DAEC 3277 DAEC RD Palo, IA 52324

Dear Harry:

l-Per our phone conversation this afternoon concerning 10CFR part l

21 or; your saf ety related order # S69896.

As discussed your part

  1. .?115263 our SS-400-3 heat code #EBY has a possible defect in the raw material.

Please check your remaining stock and ver1*,y that this heat code does not show up.

Also verify any installations that might have used said part.

Thank yo'1 for your help on this matter.

Best regards.

Sincere 1y, G&ff.

Todd White

_ FAX "" % d d. "" 4 MhW

~[%

'" 4 x.

  • ngg?g" m-309-787 8108

=

i l

l l

1 l

l 260067 i

/

9210260337 921022 t

PDR ADOCK 05000331 1

i S

PDR I

_._______------m=_..-

J

' ' ~ ~ '

"92 FRI 10801 CRAW CA D F2TTING COMPANY P.C2

=

D l

C34 A %TO 4D3 WING COMI'ANY h y o m o 44itio raq'a awcs

' ^ ~

a m ostrei 4e m bu 2, W Mr. Todd M.

White Hawkeye Valve & Fitting Co.

P.O.

Dox 319 Milan, IL 61264 Ret SS-400-3 (Heat Coda EBY)

Dear Todd:

We are writing in rogards to your cortification dated May 7, 1992 to Iowa Electric Light and Power.

our roccrds show that you sold 10 pieces of an SS-400-3, union tee, to IGNa Electric.

There is a slight possibility that there is a material defect in tho body of the SS-400-3.

The type of defect is called piping or a conterline shrinkago defact.

This is essentially a void in the material.

It is only the body with heat codes EBY that is suopoet.

Wo had identified this defect in the parts and inspected the parts 100 percent before shipping, but wo know now that we were not able to catch all the bad parts.

Pleano notify your cuutomer immediatoly about the potential probicm.

This type of defect, if it is present, would probably cause the fitting body to crack during pull-up.

Therefore it is likely to be noticed during installation or testing.

l Wo will 2oplace any of the unused SS-400-3 EBY's that your customor has.

Floase conte':t us if you have any questions.

I Sincerely,

,5nb m<.

Bruce Flusche Technical Services rdk cc:

EJZ EDS l

HAWKEYE VALVE & FITTING CO.

'M.

1260 West 11th Street P. O. Box 319 Milan. Illinois 61264 IgN L.

PHONE: (309) 787 6800 FAX: (3C9) 787 8198 SWACELOM October 22, 1992 Harry Johnson Iowa Electric DAEC 3277 DAEC RD Palo, IA 52324

Dear Harry:

Per our phone conversation this afternoon concerning 10CFR part 21 on your' safety related order # S68110.

As discussed your part

  1. P115218 our SS-600-2-6 heat code #EPY has a poscible defect in the raw material.

Please check your rtiaining stock and verify that this heat code does not show up.

Also verify any installations that might have used said part.

Thank you for your help on this matter.

Best retards.

Sincerelv, fk' Todd White l

1 l

n.-

bygk\\bd CR AWFOIID FI'PTING COM:%NY woto w.u nio 44 09 r r4t 0 A Lt9No9 PHONE 761248-4800

~~~

fax ms> 34 sero October 15, 1992 I

Subject:

SS-600-2-6 Heat Code EFY i

Dear Valued Customer:

We are vr'iting in regards to the Swagelok Male Elbott, part number SS-600-2-6.

Our records show that you may have purchased sora of those parts with the Heat Code EPY.

The part can be identified by the letters EPY stamped on the body.

A defect in the raw material that was undetectable har been discovered when the fitting was assembled for service.

The defect causes the fitting body to fail inmediately upon pulling up the nut 1-1/4 turns.

The 20* flare of the fitting body splits longitudially and will leak during system pressurization tests.

When thu nut is removed, the crack is very visible.

Unfortunately, some of these parts were shipped to our customers.

We have recalled all of our world wide inventories of this heat.

Our experience indicates the defect is found upon installation and/or testing of the system.

The number of fittings that have failed is less than 0.11.

If you have any unused inventcry of the part number SS-600 !

l 6,

Heut Cod < EPY, we would ljke to replace it.

Please contact your local distributor if you have any questions.

Crawford Fitting Company ll

-