Reissued NPDES Permit VA 0052451,issued to VEPCO
ML20115G787
Person / Time
Site: North Anna  
Issue date: 03/19/1985
From:
VIRGINIA, COMMONWEALTH OF
To:
Shared Package
ML20115G785 List:
References
VA-0052451, VA-52451, NUDOCS 8504220337
Download: ML20115G787 (46)


Text

c yi i

f %;%

?

i x

1 u

o COMMONWEALTH of VIRGINIA STitTE 11'<1TER CONTROL B0ilRD "g[L*Nll,""

211I Ilarnilton Street Post Office Box 11143 Richmond, Virginia 23230 Permit No.:

VA 0052451 (804) 257-0056 Effective Date:

March 19,1985 Expiration Date: March 19,1990 AUTHORIZATION TO DISCHARGE UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM AND THE VIRGINIA STATE WATER CONTROL LAW l.

In compliance with the provisions of the Federal Water Pollution Control Act and pursuant to the State Water Control Law and regulations adopted pursuant thereto, VEPCO & OLD DOMINION ELECTRIC COOPERATIVE

-is authorized to discharge from a facility located at Lake nna off State Route 700, Louisa County, Virginia 4

to receiving waters named Lake Anna and North Anna River, Section 3, York River Basin, Class III, Special Standards: None in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in this permit.

2.

Design and operation of facilities and/or treatment works and disposal of all wastes shall be in accordance with the application filed with the State Water Control Board and in conformity with the conceptual design, or the plans, specifications and/or other supporting data approved by the Board.

The facilities shall be operated in accordance with the conditions of the permit.

3.

The approval of the treatment works conceptual design or the plans and specifications does not relieve the permittee of the responsibility of designing and operating the facility in a reliable and consistent manner to meet the facility performance requirements in the permit.

If facility deficiencies, design and/or operational, are identified in the future which could affect the facility performance or reliability, it is the responsibility of the permittee to correct such deficiencies.

7 050411 oerd2 05042 K0500g8 W fer Control Board Executive Director, St 3

wx Date Rev. 12-82 s

itn it(firinative itetion/ Equal Opportunity Ernployer

swCn/1-80/1 PART I PERMIT NO.

VA 0052451 Page 1 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.~.rge from outfall(s) serial number (s)

Low volume waste sources 001 & 002 Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day other Units (Specify)

Measurement Sampic Monthly Avg. Daily Max.

Monthly Avg.7 Daily Max.

Frequency Type 3

Flow-M / Day (MCD)

NL NL NL NL 2/ month Estimate Total Suspended Solids NA NA 30 mg/l 100 mg/l 2/ month Grab pil& Grease NA NA 15 mg/l 20 mg/l 2/ month Grab I

1 1

2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored 2/ month by grab sample.

3.

There shall be,no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken i?t compliance with the monitoring requirements specified above shall be taken

~

at the following location (s): Flash evaporator - Unit 1 report as 001 1

Flash evaporator - Unit 2 report as 002

U022OzgW(. pI 0g >.go_g_< *F4hW 3<HWE uQzpEO. EO gg 2

J y=t gs3dr> g v:,pGz'd'3W'6j9Fo3$'8 MZO3W.2Ma gig dt']'~33o s e.iFi s *ss3d;'

!.i I_

E17Oa t.

0 gz<

9 g *z >

-2

[k L3 c

c;gw:&VOtz$ "J aoN@

fJ 1u.

r e

lt ag>n3:cp: e

~

-l

>W.QO i EgI 4 z z 4 n. O 3 w x m r, 2 n M O_,

z,y t

<o[w3 3*CCiAsU" Cee

>4J.W> EWOMUZ4_t Ot(oLMOW l

J o :la:

n*O* max N4 m

'Wa2 > Z3Im "

QeO*

E n

D0X &mm

's g u.

C2MODW33FW2'.

>r.*

x M OJ*;.6;.0 NnNm D

NN)a e N L

i a$tI I 'gso fcnImN28NW&t

.u"?

'*a j

a=,

l o,,

n ag<pOz gMJw 2O Nme4 4c*

6g2

  • O t

E=$ *jst le :r,:

z0U~

'os}s:g.MI>j$2I

'= 8s sf E* o, 0; **

.;sl *e vi "a e 0 '*

am3 3o.

  • 3te n<E<2Wbwg 8a ea: **

<$*8o,,

2<E233

3zt, 2E I3g

<>!*o.

3<E23g 3zta co.-*

eJOo gWn0E WO

                  • e o********9
  • ,g******9

!aR 1CC

                  • o g********e
  • ,g******0 ms1 LVF

!sII a ;-

con i

o_ T EWnOEhWO ***$****************

g********o

! l3E A * * $ * *

  • 4,.e********8*

4*CCCc g********e CeCCCC VD as1 tO9T i8I=>

J

,e ce4 eOW.c J msmemo_som EWnoE W0

    • o******o l3D
    • o****0*o Md=aaco ecCeCCCc 1CNJ msI e D :a &

a <* '-

  • i 83 a>

mco O4J a i < -

eawcow EWn0E W0

                • ,*****4**,4*

t

l3L
                • ,.********o**
  • e * * * * $' * *

~V3aco mCa CCCc 1dN_

NsE e0<tI l8Ia>

gWn0E W0

sR i u I r>

gWn0EEW0

! :3D 1"3 a>

gWn0E W0

32 1* 5e>

gWa0E W0 l32 l83 r>

d.g2a a "a: > l '3 a !.:e0 u!l=

E*< a

><3 doz

  • Og.

go.

Oawg g Og E EWm2Za2ay h4E0W

04y, a> f==w.

'UU s g = z5,

_g0 ~

,r0 -

<za

/

.n W2a3j

  • =a 0e &Ez>WO *<2w "S z <-

"W WWE;Eu< W *0.

>u<E 20 j>

  • > o o

eEE j

r. p;83$ g'.;zU _ I t.ma "l=gpa 3'g 1 g 5 se, g a[ E,,

i

o 3" s is
  • E*

o

5 gWg.o E4 2y,

[ z;-[J Wxwu3E>W 0kgu a Oe *3*

" :O4o,g,.

p dWaj z W 0<>,

g.g 8g:gi f1,5z0wE

m. j$ *bgE o o

g.

u,; [.6 **og4.E" 3tIG**pMg. !

>yg g 55n.

g qg ILla #<gz h""8 z[y s83_2,i.

t5-

<2

h a g

E

  • 8 E"

e8

,g [ 5o2t.633-

~I g 2 4

)jpl'.s4I Et jI

  • ,i It

].f'

,l

  • g=oOttE2>waz<2w
  • S*<

$W z3l"t

>w<z 20 gUco 2ocwu yOEE,

0' 3,

s

CCMMONWEALTH OF VIRGINIA STATE WATER CONTRCL BOARD

"JJ.7,'%"CIL'Of.'"J'.",;',"JI-, '

"""D'AnWZ'WI;;ti?27,e"H";is"#5M"J, -1:

INDUSTRIAL MAJOR 03/19/85 ET ATE W A.T.E..R.C. O.N.T.R..O.I,. BO A RD s.

NAME VEPCO-NORTH ANNA POWER STATION A oO R E,,

va0052451 002 VALLEY REGIONAL OFFICE P.O. BOX 26666 r=""'rauM.ER

'"n::$ $=

P.O. SOX 268 RICHMONU VA 23261 BRIDGEWATER, Vt. 22812

~

703-828-2595 rACluTv LOC ATION FILE NO.22.4740.

rROM TO

NOTE, R.......,.............

.....c.=6.............

....,.1,.6......

... u,,.. c. c..v.....

e...u,.mc, PARAMETER

  • ^ " ' ' '

AVERAGE M AKIM UM UNITS MINIMUM AVERAGE MAXIMUM UNITS

""*'I

001 F L O.y REPORTED J

...'J,",;'.,

100 2/;;

EST 002 PP R EFORTE D **##################

Y

...f,",;g..,,

6.0000**********

9.0000 SU 2/N GRA9 004 TOTAL SUS. SOLIDS REPORTED ####################

...f,;;g.,

30.0000 100.0000 MG/L 2/M GRAB S00 OIL &

GoESSE REPORTED #####*##############

...f,,;g,,,,

19.0000 20.0000 r4G/L 2/M PAa REPORTED

" J REPORTED

+

....e.,

u.. as.n, REPORTED 0

p

.a.s e, REPORTED us..es.=,

4

.svi.se.6e..ast,...ua..as.se,... c. eses.gr.

B Y P A S S E:.S OCCUR NCE.

G G

AND

' OVERFLOWS S CERTIFY UNDER PENAL 1Y OF LAW THAT 4 HAVE PERSONALLY EX AMINED AND AM TYPED OR PRINTED N AME SIGN ATU RE CERTIFICATE NO.

YEAR MO DAY F AMIL!AR WITH THE INFORMATaDN SUBMITTED tN THa5 DOCUMENT AND ALL ATTACH-MFWTs AND e HAT. BASE D ON MY INOutRY OF THOSE INDIVIDUALS IMMEDIATELY RE.

PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SenNSIBLF FOR OSTAINING THE INFORMATION I SELIEVE THE SuSMITTED INFORMA.

TION 13 TRUE. ACCUR ATE AND COMPLETE. I AM AWARE THAT THERE ARE SIGNIFt-C ANT PEN ALTIES FOR $USMITTING F ALSE 6NFORMATION. INCLUDING THE POSS8BeLI-TV OF FINE AND IMPRISONMENT. SE E 18 U S. C 01001 AND 33 U $ C. 91319 IPenal-t es b'ete.under these s4ewtes enay enclude flnes up to $10.000 and/or spesimum impr of sn 6 mon *e end 5 veers )

TYPED OR PRINTED N AME SIGN ATU RE NUM BER YEAR MO DAY SWCB NPDES FORM 5 PAGE OF o

SWCB/1-80/I PART I PERMIT NO.

VA 0052451 Page 2 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.a.rge from outfall(s) serial number (s) 003 - Process waste clarifier.

Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day Other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Avg..j aily Max.

Frequency Type D

3 Flow-M / Day (MCD)

NL NL NL NL 2/ month Estimate l

Total Suspended Solids NA NA 30mg/l 100 mg/l 2/ month Grab E0il & grease NA NA 15 mg/l 20 mg/l 2/ month Grab i

I j

2.

The discharge shall have a pH value between 6.0 and 9. 0 at all times and shall be monitored 3

2/ month by grab sample.

'3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4,.

Sampics taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

final outfall of clarifier.

COMMONWEALTH OF VIRGINI A STATE WATER CONTROL COARD

'0"J/L".s ",E'f,",OJ'".?."J1. i

"""D'.7.n"J71 A'rNWs M&"O';'J"f'U M",6"'* *8 INDUSTRIAL MAJOR 03/19/85 a

t;T A T E W A.T.E..W.C. W.N.T.R..f.? L.

BOA %3 VEPCO-NORTH ANNA POWER STATION amar

' ~

4DoRESS uannsp451 001 VALLEY REGIONAL OFFICE P.O. 80X 26666

  • CO*'

P.O. 80x 268 RICFMOND Va 23261 BRIDGEWATER, VA. 22812 703-828-P.S95 r A C. L. Tv R.a........;.....6......,...

LOC ATIO N FILE NO.22-4740.

NOTE x

PARAMETER AVERAGE M AXIM UM U N ITS MINIMUM AVERAGE MAXIMUM UNITS 091 FL O 'q REPORTED MGD

        • 4**4** ********************

2/'t CST J

002 pg REPORTED 11

.. /"," "'J..,

  • 4**********4*****e4 s.0000 **********

9.0000 SU p/h r,o t A 004 TOT *.L SUS.SULIOS REPORTED ********************

..J,","L o,,

44**4*******4*****44

-****44****

30.0000 100.0000 MG/L 2/M GcAR 500 OIL 6

~~~

~

~ '

~~

GwEASE REPORTED ********************

.. l.",","'J..,

44******4***4*****44 I c;. 0 00 0 20.0000 MG/t 2/M npaa REPORTED

...P.,.....

REPORTED REPORTED

.. :,, J.,

REPORTED 6.....

RYPASSES OCCu CES M G G

AND

  • OVERFLOWS TYPED OR PRINTED N AHE SIGN ATURE CERTIFICATE NO.

VEAR MO DAY 8 CERTeFV UNDER PENALYY M L AW THAT I HAVE PERSONALLY EM AMeNED AND AM ME TS AND THA A ED O V N R f OSE D 5IMME AT,

PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SPUNss9LE FOR ORT AINING THE iNFORMATION 4 BELIEVE THE SUBMITTED INF.RMA.

TION IS TRUE. ACCUR ATE A7.0 COMPLETE. I AM AWARE THAT YMERE ARE SIGNIFI-C ANT PE NALil?S FOR SUGMlf TING F ALSE INFORM ATION. INCLUDaNG THE POSUBILO-T, OF FINE AND IMPRISONMENT. SEE 18 U. 8. C. E Scot AND 23 U. 5 C. 91319 IPeasi-Det undet meee steeuwe may melude fmes up to $10.000 and/or monsmum imensonment of

""'**"*'**d'""'I TYPED OR PRINTED N AME SIGN ATURE "U"

NUMBER YEAR MO DAY SWCB NPDES FORM 5

"^GE o'

e

SWCB/1-80/1 PART I PERMIT NO.

VA 0052451 VEPC0 - North Anna - Units 1 and 2 Page 3 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch: rge from outfall(s) serial number (s) 004 011 Separator Such discharges shall be limited and monitored by the permittee as specified below EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Avg.. Daily Max.

Frequency Type 3

Flow-M / Day (MCD)

NL NL NL NL 2/ month Estimate Total Suspended Solids NA NA 30 mg/l 100 mg/l 2/ month Grab pil& Grease NA NA 15 mg/l 20 mg/l 2/ month Grab 2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored 2/ month by grab sample.

~3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4 Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Final outfall of separator.

COMMONWEALTH OF VIRGINIA STATE WATER CONTROL COARD

L".'.VA"
.W':*,.=J2'in"?."z.,i

"""*"aSMn"2;"2L's;4U2,%"l iAf"PTL",6. osi INDUSTRIAL MAJOR 03/19/R5 ST ATE W A.T.E..R C. O.N.T.R..O.L.O A R D i.

VEPCU-NORTH ANNA POWER STATION NAME

~

A oO R ESS VA0052451 004 VALLEY REGIONAL OFFICE P.O. BOX 26666 PERM'raUM.ER

"*:=^;;=

P.O. BOX 268 RIChMOM VA 23261 9RIDGEWATEll, VA. 22812 703-828-2995 rAciuTv LOC ATiON FILE NO.22-4740.

rROM TO

NOTE, R........,.............,,,,,,

....m.........

...e................

PARAMETER Z- " " "...* ^ "';"

AVERAGE M AXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 FLON

~

REPORTED

,,.;f,;;g.,

MGD 2/M rST 002 pu REPORTED

'.5

  • u#######*

..lf.", g.,

        • 6***** o*********

6.0000*******###

9.0000 SU 2/M GcM6 004 TOTO.L SUS.SOLIUS REPORTED **********

,,.lf,",;g.,,,

  • s******** **********

30.0000 100.0000 MG/L P/M Gc AH 500 01L 6, GREoSE REPORTED

.. f,", g.,

15.0000 20.0000 MG/L 2/M GPA8 REPORTED

...P,. e.s t,

._R E PO RTE D

..lf,".:g...

REPORTED REPORTED A,a.tre.som b P.aws,.s.u s..u.as,.....aees.se,.

^

BYPASSES OCCUR NCES g g g g AND O V EH f'LO W S s

1 CERTIFY UNOER PENAL TV OF LAW TMAT I MAVE PERSONALLY EXAMINED AND AM TYPED OR PRINTED N AME SIGN ATURE CERTIFIC ATE NO.

VEAR MO DAY F AMell AR WITH THE INFORM ATION SUBMITTED IN THt$ DOCUMENT AND ALL ATTACH-MEJ4TS AND TH AT. SASED ON MY INGuiRY OF YMOSE INDIVIDUALS IMMEDIATELY RE.

PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SPONSISLE FOR OSTAIN'NC THE INFORMATION I BELIEVE THE SUBMITTED INFORMA-TtON IS TRUE, ACCUR ATE AND COMPLETE. 6 AM AWARE THAT THERE ARE SIGNIFB-CANT PEN Att'IES FOR SUBMITTING F ALSE INFORM ATION, INCLUDING THE POS$18tLi-TY OF FINE END IMPRISDNMENT. SEE 18 U, S C 61001 AND 33 U S. C. 41319. (Peneb ties

of kt. undue these statuses may enclude f.ews up to $10.000 and/ae enemmum _. -

wn s amnes sad 5 pes )

TYPED OR PRINTED N AME SIGN ATU RE NUM.ER YEAR MO DAY SWC8 NPDES FORM S PAGE Or a

SWCB/1-83/M PERMIT No. -VA 0052451 PART I

- Pagi 4 cf 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS t

1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to discharge from outfall(s) serial number (s) 005 Sewage Such discharges shall be limited and monitored by the' permittee as specified below:

EFFLUENT CHARACTERISTICS DISCHARGE LIMITATIONS-MONITORING REQUIREMENTS Monthly Average Weekly Average Instantaneous Frequency Sample Type

~

Limitation Min.

Max.

Flow (MGD)*

-- ~ y 1/ month Es timate BOD 30 mg/12.27kg/d 45 mg/13.40 kg/d 1/ month Grab 5

0 2

'.4 5 mg/1 40 kg/d 1/ month Grab 3

Suspended Solids mg/l kg/d Residual (mg/1)( }

NA NA C1 2 pH (standard units) 6.0 9,0 1/ month crab

,2.

(a) No more than NA of all total chlorine residual analyses shall be outside the range NA through NA milligrams per liter for any one calendar month.

(b) Any NA consecutive test results not within the range NA through NA milligrams per liter shall be immediately reported in accordance with paragraph A(7)(a) of Part II.

(c) No single chlorine residual analysis shall exceed NA mg/l at any time.

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Final Outfall.

  • The de, sign flow of this treatment facility is 0.02 MGD. The permittee shall monitor. flow as specified above (See the Board policy for Sewage Treatment Plant Loadings effective February 1, 1981).

O

COMMONWE ALTH OF VIROINI A CTATE WATER CONTROL COARD

1";'? %".'"J","A7.ZJT;';"I"mi

""'*"diSF.u"L"1 A'3"T'%%"'"3' "i'f61",4"*** l. INOUSTRIAL MAJOa 03/19/B5 O

LT AT3 W A.T.E.Q.C3.N Ti O.t. BO A",.D q.

s As WF9C l NAME VEPCO-NORTH ANNA POWER STeTION

~

A DD R ESS van 0MP491 on9 VALLEY REGIONAL OFFICE

"'CO:"

P.O. Box 568

~

P.O. 80X 26666 RICHMOND VA 23261 BRIDGEWATER, VA. 22812 703-828-2595 rAC uTY

..A.

.A.

..A.

.a' LOC AT ION FILE No.22 4740.

NOTE:

R. A.... A... =. A.6

.v.U e ve..

.............e...

..A.T.,.....A....

.MAm............A....

"O,*;"

PA R AM ETER

"*/

or AVERAGE M AXIM UM UNITS MINIMUM AVERAGE MAMIMUM UNITS 001 FLO.9 REPORTED J

..U."."'..,

MGrj 6******d6*********************

1/P FST 002 pg REPORTED ********************

                  • c

...o","," 0.,e,

6660****************

A,nnnp **********

Q.nnnn SU 1/'4 GQa4 003 gogg REPORTED

..l"."."'..,

2.2700 3.4000 KG/D; ****6***6*

30.Onnn 45.nnon M G /i_

1/M Gona J

004 TOTel

~~~

SUS.SULIOS REPORTED

.. U."." U..,

2.2700 3.4000 KG/C 30.0000 45.0000 MG/t I/M A""

REPORTED

.. :.","," 2..,

REPORTED

..U,""0..,

REPORTED

...U.

.. net REPORTED P..r...tT. set u g.. es Gr qTlo. A b P..tet?.5.ug.f *s A.T..it Cu....T.

^

BYPASSES OCCUM CEs M G.

K G AND

' OVERFLOWS TYPED OR PRINTED N AME SIGN ATU R E CERTtFIC ATE NO.

YEAR MO DAY I CE8tTIF Y UNDER PEN ALTV OF L AW THAT I HAVE PFRSONALLY E N AMINED AND AM f AMILIAR W8TH THE INFORMATtON SUBMITTED IN THis DOCUMENT AND ALL ATT ACH.

MENTS ANO THAT S ASED ON MY INQUIRY OF THOSE IND.vtDUAL5 eMME DI ATELY Rt PRINCIPAL EMECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SFUNSIBLE FOR ORT AINeNG THE INFURM A ftON 6 SE LIEVE THE SuaMIT TED INFORMA.

ItON l$ TRUE. ACCUR ATE ANO COM*LETE. 4 AM AWARE THAT THE RE ARE SIGNIFt-C ANT PEN ALTIES FOR SU8VITYtNG F ALSE INFDRM ATION. INCLUDING THE POSSIBILB-TV OF FI'JE AND IMPMISONMENT SEE 18 U. $ C E 1001 AND 33 U. S C. 61319 (Penal-e.es under thew esatvees mey enetwin fines up to 310,000 and/or maximum emonsonment of en 6 nenmo end 5 yeen )

TYPED OR PRINTED N AME SIGI4 ATU R E "Me NUMBER YEAR MO DAY SWCB NPDES FORM 5 CAGE Or

SWCB/1-83/M PERMIT NO.

VA 0052451 PART I Pzg3 5 of 18 A.-

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective.date and lasting until the permit's expiration date, the permittee is authorized to discharge from outfall(s) serial number (s) 006 sewage Such discharges shall be limited and monitored by the permittee as specified below:

J EFFLUENT CHARACTERISTICS DISCHARGE LIMITATIONS MONITORING REQUIREMENTS Monthly Average Weekly Average Instantaneous Frequency Sample Type Limitation Min.

Max.

Flow (MGD)*

--i l/ month Estimate l

BOD 30 mg/11.13kg/d 45 mg/l 1.70 kg/d 1/ month Grab S

Suspended Solids 30 mg/11.13kg/d 145 mg/l 1.70 kg/d 1/ month Grab Residual (mg/1)( }

NA NA l

C12 pH (standard units) 6.0 90 1/ month Grab 2.

(a) No more than NA of all total chlorine residual analyses shall be outside the range NA through NA milligrams per liter for any one calendar month.

(b) Any NA consecutive test results not within the range NA through NA milligrams per liter shall be immediately reported in accordance with paragraph A(7)(a) of Part II.

(c) No single chlorine residual analysis shall exceed NA mg/l at any time.

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following

]

location (s):

Final outfall.

1

  • The design flow of this treatment facility is 0.01 MGD. The permittee shall monitor flow as specified above (See the Board policy for Sewage Treatment Plant Loadings effective February 2, 1981).

5

COMMONWEALTH OF VIRGINIA STATE WATER CONTROL COARD

i!"a7,%"e;."i3"."J,7.'.MJ'." 7."%

""'*"ei Cin"JSA'5.*W' fin"#'#' "rf6M",6"'=xt INDUSTRIAL MAJOR 03/19/85 J

LT AT3 W A.T.P.%) CS NTLM* E. DO AM t.

o=A6oprec.)

VtiPCO NOH1 H ANNA POWER STATION NAML

~ ~

r.oo R E SS V40052451 006 VALLEY REGIONAL OFFICE P.O. 00X 26666

""" " " u M.E R

=::: :

P.O. E0x 568 AIChriONC VA 23261 BRIDGEWATER. VA. 22812 703-828-2595 rAcluTv

-o

.A.

..A.

.Av

'OC ATION FILE No.22-4790.

r"O" m

NOTE, R.A......,A-......As.,...........

..........L..........

.. Ass,1,Y O. LOA.,N.

.. A LS., O. C ONC. 4,. A,90N PARAMETER

"*/

" " ^ ' " ' "

AVERAGE M AXIM UM U NITS MINIMUM AVERAGE MAXIMUM UNITS 001 Flog REPORTED

                  • e *********c e********e

.. lo","." 0. -,

MGD

            • 6***
                  • e *********e 1Ma eST 002 pn REPORTED
                              • 4****

'.1

                  • e

..U".70..,

44****Ge****6*6***An A,nnnp

                  • e Q.nnnn SU

} /sa Goup 003 bOOg REPORTED

...'",.IO. -,

1.1300 1.7000 KG/D' ****4*****

~10.000n 45.0000 MG/L 1/M Gary 004 TUTAL

~ ~ ~~~ ~

SUS.50LIUS REPORTED

                  • e

-.0.".70.-,

1.1300 1.7000 KG/C 30.0000 45.0000 MG/L 1/M c,vaa I

REPORTED

...P p m.e g, REPORTED

...'f. " 0..,

REPORTED

.. 9. m. t, REPORTED

...r.e..e.n t.,.

p d..

1,go9e Ab P..MI,... 900 88.N1. O. Comas.N,.

BYPASSES OCCU ft NCE.

g g

g AND

' OVERFLOWS TYPED OR PRINTED M AME SIGN ATURE CERTIFIC ATE NO.

VEAR MO DAY I CERTIFY UNDER PENALTY OF LAW THAT 4 MAVE PERSONALLY EX AMINED AND AM f AMILI AR WITM THE INFORMATION SUSMITTED IN THIS DOCUMENT AND ALL ATT ACM.

ME"dTS AND TH AT. SASED ON MY t-QUtRY OF THOSE INDIVIDU ALS IMMED6ATELY RE.

PRINCIPAI. EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPNCNE DATE SPUNHSLE FOR OST AINING THE INFORM ATION I BE LIEVE THE SUSMITTED INF ORMA-TION IS TRUE. ACCUR ATE A*;D COMPLETE. t AM AWARE TH AT THERE ARE SIGNIF1-C ANT PE NALTIES FOR So.MITTING F ALSE INFORM ATION INCLUDING THE POS$1BIL1-Tv OF FINE AND IMPRISONMONT. SEE 18 U. S. C 6 1001 AND 33 U. 5. C. e 1319 (Penal.

tin undw thew statutes sview enoisde hues up to $10.000 and/m snenwnum impe. _

. of ke 6 nenes and l yeere n TYPED OR PRINTED N AME SIGN ATURE g"""

NUMBER YEAR MO DAY SWCB NPDES FORM S PAGE Or

SWCn/1-83/M PERMIT No, VA 0052451 PART I peg 2 6 cf 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMEffrS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the pernittee is authorized to discharge from outfall(s) serial number (s) 007 sewage Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTICS DISCHARGE LIMITATIONS MONITORING REQUIREMENTS Monthly Average Weekly Average Instantaneous Frequency Sample Type Limitation Min.

Max.

Flow (MCD)*

-5

/

l/ month Estima te BOD 30 mg/11.13kg/d 45 mg/l 1.70 kg/d 5

1/ month Grab 30 mg/1 13kg/d mg/l kg/d 1/ month Grab 1

45 1.70 Suspended Solids NA NA C1 Residual (mg/1) 2 PH (standard units) 6.0

9. 0 1/ month Grab 2.

(a) No more than NA of all total chlorine residual analyses shall be outside the range NA through milligrams per liter for any one calendar month.

(b) Any NA consecutive test results not within the range NA through NA milligrams per liter shall be immediately reported in accordance with paragraph A(7)(a) of Part II.

(c) No single chlorine residual analysis shall exceed NA mg/l at any time.

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

3 J

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Final outfall.

  • The design flow of this treatment facility is 0.01 MGD. The permittee shall monitor flow as specified above (Sea the Board policy for Sewage Treatment Plant Loadings effective February 1, 1981).

O

CUMMENWEALTH OF VIRGINIA STATE WATER CONTROL COARD

..., x uo,..,., y..-,...... b..., e)... x )

INDUSTRIAL MAJOR 03/19/85 etesuvve4

-,.... w v.so..

....,,re.

.16..

n..e-. sert.

.,)

D SCH A,m E MiNITORIMw R POa7 MR i.............:

VEPCQ-NORTH ANNA POWEH STATION NAuE

~

A oo,, ES S VA0052aS1 007 VALLEY REGIONAL OFFICE P.O. 80X 26666 PERMiTNuM=ER

"'* :::=

P.O. BOX 268 RICHMOND VA 23261 BRIDGEWATER, VA. 22812 703-828-2595 rAC L.TY LOCAT50N FILE NO.22.4740.

rROM TO NoyE,........,,.......,,,,,,..,,..

.. r... c.,e et..t,..

. e. p.. a,.

.u..,s.,..

Loa.,.

.u. u r,...........,s ose PA R A M ETE R

"*/

  • ^"ll" AVERAGE M AXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 FLOW REPORTED
          • 440*c
                  • c

..;f,,;U.,.,

4G0

                  • c 1/M EST 002 PH REPORTED V'

g,,,,

                                      • e 6 0000 **********

9.0000 SU 1/M GRAB 093 8005 REPORTED

..lo",",;'..,

1.1300 1.7000 KG/C; **********

30.0000 45.0000 MG/L 1/M GPA6 J

004 TOTAL SUS.SULIDS REPORTED

.. lo",",;'..,

1.1300 1.7000 KG/0 30.0000 45.0000 MG/L 1/M G'4 H J

REPORTED

......T..,

REPORTED

..l."",""..,

REPORTED REPORTED

...n......n..................,.

oCCl#,I.D.CE.

[O.;

  • 7*7 ^ *.*y De OPERATOR IN RESPONSIBI.E CH ARGE DATE eTPASSES AND

, OVERFLOWS TYPED OR PRINTED N AME SIG N ATU R E CERTirIC ATE NO.

YEAR MO DAY 1 CERTtF V UNDf R PEN. Liv O' L AW TMaf t HA'vE PERSONALLY EM AMINED AND AM ME 5 AND THAT eA E v eNOU R F

OSE D 5 6MMEDIAT Y PRINCIPAL EMECUTIVE OF FICER OR AUTHORIZED AGENT TELEPHONE DATE SPONSISLE FOR OST AINsNG THE INFDRNIATION I BELIEVE THE SUBMITTED INFORMA.

YlON IS TRUE. ACCUR ATE AND COMPLETE. I AM AWARE THAT THERE ARE SIGNIFB-CANT PENALYlES FOR SUSMITTING F ALSE ONFORMATION. INCLUDING THE POS$1 BILI-TV OF FI 4E E IS U. S. C. 5 1001 AND 33 U. S. C. 0 1319. IPeneb t.en epide,NE A,ND IMPRISONMENT.

ghe steouses rnav inctuoe fines up to $10.000 andeor monwnuse impneenseent of aa t awies end 5 vm l TYPED OR PRINTED N AME SIGN ATU R E NUM.ER YEAR MO DAY SNCB NPDES FORM 5 PAGE Or

SWCB/1-83/M PERMIT NO.

VA 0052451 PART I Paga 7 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to discharge from outfall(s) serial number (s) 008 sewage Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTICS DISCHARGE LIMITATIONS MONITORING REQUIREMENTS Monthly Average Weekly Average Instantaneous Frequency Sample Type Limitation Min.

Max.

Flow (MCD)*

1/ month Estima te BOD 30 mg/11.13kg/d 45 mg/11.70 kg/d 1/ month Grab S

Suspended Solids 30 mg/11.13kg/d 45 mg/11 J0 kg/d 1/ month Grab Residual (mg/1)( )

C1 NA NA 2

pH (standard units) 6.0 9D 1/ month Grab 2.

(a) No more than NA of all total chlorine residual analyses shall be outside the range NA through NA milligrams per liter for any one calendar month.

(b) Any NA consecutive test results not within the range NA through NA milligrams per liter shall be immediately reported in accordance with paragraph A(7)(a) of Part II.

(c) No single chlorine residual analysis shall exceed mg/l at any time.

NA 3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Final outfall.

  • The design flow of this treatment facility is 0.01 MGD. The permittee shall monitor flow as specified above (Sen the Board policy for Sewage Treatment Plant Loadings effective February 1, 1981).

CCMMUNWEALTH OF VIRGINIA GTATE WATER CONTROL COARD

"Ji,7,"UJ."J'".1","2.l*.)'"7,';"i"1,3

""" dis 7Ai"J51 As"JTl fin'i"H'IAf"f'T6M",'3"'**l INOUSTRI AL f4AJOR 03/19/95 LT A T3 W.t.T.h.i.C.,%.N T;st.1..O AL@

4 Prse )

VEPCO-NORTH ANNA PONER ST!LTION NAME

~ '

~

A Do R ESS w o os24c;1 non VALLEY REGIONAL OFFICE "E""'T N uM.E R P.O. BOX 268 P.O. BGX 26666 SIChMOND VA 23261 BRIDGENATER, VA. 22812 e.,,,..........

703-828-2595 rACluTv FILE NO.22-4740.

rao*

To LOC ATION

NOTE, R...............A...........

..M.

l

..m.................

PARAMETER

",*/

AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 p(g'q REPORTED

                  • a*********c o********e J

..lf,",';'..,

MGn

            • 4**o**********
                  • a 1/n eST 002 pg REPORTED

'I -

                  • a

..lJ."."'..,

SU

-s.nnon **********

9.nnnn EU 1/M G o t. P J

On3 9003 REPORTED

                  • e

.. lf.""'J..,

1.1300 1.7000 KG/D' **********

30.0000 45.0n00 MG/L 1/M GoA4 004 TOTAL SUS.SULIOS REPORTED

                  • e

.. if."."'J..,

1.1300 1.7000 NG/n

          • 4****

30.0000 45.0000 MG/l.

1/M r,W p REPORTED

~

x::,;;':..,

REPORTED

..lf,":'..

J I

REPORTED

.. e v e.n.e s, p..

w. se, REPORTED

...r.. e.s s, u r.

as..,

A..e,s..a 6 e..as e,..ev s.. as........m ee.se,e EB Y P A S S E S OCCU CES g

g, g pg a AND

, OVERFLOWS TYPED OR PRINTED N AME SIGN ATURE CERTIFIC ATE NO.

YEAR MO DAY S CERTIFY UNOFR PENALTY OF L AW 1 MAT I HAVE PEftSONALLY FM AMINED AND AM M

TS AND THAT ED Y IN R O E

V DU $ IMMED4 AT Lv PRINCIP AI. EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE

$8%NSISLE F OR OBT AINING THE iNFORMATION I REtttvf THE SUBMITTED INFORMA.

Yione IS TRUE. ACC'S WARE TMAT THE Af ARE SIGNIFl C ANT PENALTif 5 FO. ATE AND COMPLE TE. t AM A,4TtON, INCLUDING THE POSSIGILl-SUBMtTTING F ALSE 6NFORA e s.OF F.INE AND IMP.tSONMENT.enchne= hos up to $10.000 and/or manwnw C. 91319. IPensi-TV sea 18 t' S C S 1001 AND 33 U. S und these -seutes may unpenonment of

""*******"d8"'"'

TYPED OR PRINTED N AMg SIGN ATURE c"","

NUM.ER YEAR MO DAY

^

SWCB NPDES FORM 5 PAGE Or

m Sucs/1-so/I PART I PERMIT NO. VA 0052451 Page 8 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.~.rge from outfall(s) serial number (s) 009 Ground water, storm water runoff and backwash from sand filters.

Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Avg.j aily Max.

Frequency Type D

3 Flow-M / Day (MCD)

NL NL_

NL NL 2/ month Estimate Total Suspended Solids NA NA 30 mg/l 100 mg/l 2/ month Grab l

2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored 2/ month by grab sample.

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4,.

Sampics taken in compliance with the monitoring requirements specified above shall be taken at the following location (s): Effluent of settling pond.

~

h CEMMUNWEALTH OF VIRGINI A STATE WATER CONTROL BOARD e4 u,,m

..wA

.....g...m...

1,..

m uor, or,...,, s,..

...,fDM R)e g.

1 INDUSTRIAL MAJOR 03/1o/05

......, u..n

s...

c....)

DISCN Aa E Ma NITAINC. t.EPO4T STA TE W A.T.E..R.C.O.N.T.R..O.L BO A R D i.

A VEPCO-NORTH ANNA POWER STATION NAME

~ ~

cooRESS VA0052451 009 VALLEY REGIONAL OFFICE P.C. BOX 26666 PEaM'r auM=Ea a',, =:::a:=

P.O. BOX idb8 RICHMOND VA 23261 BRIDGEWATER, VA. 22812

, AC uTv 703-828-2595

.A.

FILE NO.22-4740.

LOC ATION rROM TO NOTE: R.......

..........A

..........m......

PA R A M ETE R

  • ^ " ' ' '

AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 FLO.

REPORTED

                1. e*
  • ce*#w#cea

,,ff,;;7,,,,

MGC

                  • 9
    • n******c
                  1. c 2/'i E5T 002 pH REPORTED Y'

,,;f,a,;g,,,

~.0000 **********

9 0000 SU 2/M GRA8 5

004 total SbS.50LIUS REPORTED ****#####**#######e*

..lf,",;g,,,

                        • 6*******

30 0000 100.0000 MG/L P/M GPAe REPORTED

......r...

REPORTED R_E PO RTE D

..if,1 'J..

REPORTED

..ff.::2...

REPORTED

...e...s s, us.....,

A..e e...t e...eev

....e...s..r........es,.

BVPASCES OCCu pe ENCES g

g g

AND

' OVERFLOWS f CERTaFV UNDER PENALTV OF LAW THAT I MAvf PERSONALLY EM AMINED AND AM TYPED OR PRINTED N AME SIGN ATURE CERTIFIC ATE NO.

VEAR MO DAY F AMiLI AR vnTM THE I FCAMATIG8. SUP%elTTED IN TMIS DOCUMENT AND ALL ATTACM.

ME;dTS AND THAT, SASE D ON MY INoumv Of' TMOKE IMOsviDUAL5 IMMEDeA TELY RE.

PRINCIPAL EMECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SPONSIBLE.FOR OSTAIN'NG TMt INFORM ATION a SE LIEvf THE SUBMITTED INFORMA.

TON IS Y UE. ACCURATE AND COMPLETE I AM AWARE THAT THERE ARE SIGNIFS-CANT PEN AL itES FN.4 508MtTTrMG F ALif INFORM AftON, tNCLUDING THE POSS195LB-TV OF F l

4 se usad.eNE AND IMPthose steiine, SONMENT SEE 18 U S. C. E li.pl AND 33 U. 8 C. g 1319. (Penal.

oms, incewee tenes up to $10.000 encuer momenw ampneenseens et

  • * " # 8 "#' '

TYPED OR PRINTED N AME SIGN ATU R E NUMBER YEAR MO DAY SWCB NPDES FORM 5 PAGE Or e

sucn/1-80/I PART I PERMIT NO. VA 0052451 Page 9 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.Nrge from outfall(s) serial number (s) 010 (Discharge of Condenser Cooling Water from Waste Heat Treatment Facility at Dike 3).

Such discharges shall be limited and monitored by the permittee as specified below EFFLUENT CHARACTERISTIC DISCHARGE L1HITATIONS MONITORING REQUIREMENTS kg/ day other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Avg., Daily Max.

Frequency Type L

3 Flow-M / Day (MCD)

NL NL NL NL 1/ day Calculated 9

  • Heat Rejected NA NA NA 13.54 x 10 BTU /Hr.

1/hr.

Calculated

  • & Temperature NL NL HL NL 1/hr.

Recorded 8

See "Special Conditions Nos. 7 & 9.

The value reported for heat rejected is based on calculations which employ the change in temperature across the condensers for Units 1 & 2.

Temperature data measured at the discharge from Dike #3 shall be submitted quarterly as described in Special Condition #9. Heat rejected rate submitted monthly shall be a calculation of the maximum heat directed to the waste heat treatment facility from Units 1 and/or 2.

2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored N/A.

"3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

COMMONWEALTH OF VIRGINI A STATE WATER CONTROL COARD

L".'",";."."."S'?*," J1J';.P"*."..,

"""*"#Sch"i"1 A'81"Cin"ii'l Ai"f'T6M"14"'"'

INDUSTRIAL MAJOR 03/19/95 LT AT3 W A.T.E.d.C.6 oresc.L SO A"AO

$ N TC A g.

e 3

VEPCO-NORTH ANNA POWER STATION "A=E

~ ~

~

aooRESS v 6 0 0524c;1 010 VALLEY REGIONt.L OFFICE PERMIT NUMBER

  • 23 ^::'

P.O. 90X 268 pg gg gg RICM040 VA 23261 BRIDGEWATIER, VA. 22812 703-828-2595 rACluTV LOC ATIO N FILE NO.22-4740

'"o"

'o NOTE R...

............M.

...u,,..............

PA R A M ETER

"*/

AVERAGE M AXIMUM U NITS MINIMUM AVERAGE MAXIMUM UNITS 001

- I p L g.,

REPORTED

                  • a *********a *********a

...f "O 'J..,

MGD

                  • a *********a *********a 1/0 calc 005 TOTEL s

CL2 REPORTED *******************a

                    • *********a

.. JJ,","'J.,

  • b e * * *
  • k il
            • 4***
      • 6*****a

_ pone M r./l _

1 / t.'

r,Q t o 090 TEMP.

REPORTED ns,,***************g

..Jf,"3',.,

6********6**6*****4*

'.' ******e***

c 1/4 art-J 083 HEAT

' ^

s REJ(10**9)

REPORTED **********

                  • e

..J.",""'..,

  1. 4********

13.5400 aTu/r ******************** **********

1/H cal r J

REPORTED

...n..,

REPORTED REPORTED p

..ar...,

REPORTED 4

.vi.

....n BVPASSES OCC U R R ENC ES M G

{K Q AND

. OVERFLOWS TYPED OR PRINTED N AME SIGN ATURE CERTIFIC ATE NO.

VEAR MO DAY f CE.T*FY UNDFR *ENALTV OF L AW THAT 4. AVE PERSON ALLY E nt AMINED AND AM E'o ne', N E DI 5 ME DI A T Ly PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE Ts ANr THAT SPOs45sSL E FOR Opv AINING Te9E INFO,* U ATION t SEL8 eve THE SUBMtTTED INF ORMA.

YlO8e IS TRUE. ACCUR ATE AND COM L ETE 4 AM AWARE THAT YMERE ARE SK,NIFl-C ANT PENAL TIES FOR SU'9MITTING F ALSE thFORMATION. fNCLUDtNG TME POSSealLt-eies u.see me.ND.egeus.R'50NMt NT. SE E 19 U S C. 9 1001 AND 33 u 5 C E 1319 (Peams.

T W OF f tNE A eMP n vaev sectuvie hans up ee $10,000 aamer of

'"" * # I ""'I TYPED OR PRINTED N AME SIGN ATURE c""$ ^

MUMDER VEAR MO DAY SWCB NPDES FORM S PAGE Or a

C3C66:OD/O '

~

~

. PERMIT NO.

NA V0052451-PART I Pcg310 cf _18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREME?rrS 1.

During the period beginning with the permit's effective date and lasting until the_ permit's expiration date, the

~

permittee is authorized to discharge from outfall(s) serial number (s)0ll Permanent STP Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTICS DISCHARGE LIMITATIONS MONITORING REQUIREMENTS Monthly Average Weekly Average Instantaneous Frequency Sample Type i

Limitation Min.

Max.

Flow (MGD)*

. (

l/ month Measured BOD 30 mg/13.40kg/d 45 mg/l 5.llkg/d 1/ month Grab 5

i Suspended Solids 30 mg/13.40kg/d

45 mg/l 5.llkg/d 1/ month Grab Residual (mg/1)( '

C1 l/ day Grab 2

pH (standard units) 6.0 9.0 1/ month Grab i,

2.

(a) No more than 12 of all total chlorine residual analyses shall be outside the range 1.0 through 2.0 l

milligrams per liter for any-one calendar month.

I (b) Any 2

consecutive test results not within the range 0.5 through 3.5 milligrams per liter shall be immediately reported in accordance with paragraph A(7)(a) of Part II.

(c) No single chlorine residual analysis shall exceed 4.0 mg/l at any time.

4 s

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

j 4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Final outfall.

l j

CThe design flow of this treatment facility is 0.03 MGD. The permittee shall monitor flow as specified above (Sze the Board policy for Sewage Treatment Plant Loadings effective February 1, 1981).

I

CUMMONWEALTH OF VIROINI A STATE WATER CONTRCL BOARD

"2'",*:."".","M**"J'.A"."M*.".,

""'*"otS2WA"1a'si.TT"f'idi"C3ii",.f'T624"**.21 INDUSTRIAL MAJOR o3/19/85 ST ATE W A.T.E..R C.O.N.T.R..O.L.

SOARD i.

A VEPCO-NURTH ANNA POWER STATION i

NAME

~

i AooRESS VA0052451 011 VALLEY REGIONAL OFFICE 4

P.O. 80X 26666

"= R" "u M.E R

  • 'J :::"

P.O. 80x 268 RICHN0hD VA 23261 BRIDGEWATER, Va. 22R12

'703-828-2595 rAC.L TV

.A,

..A.

.A.

LOC A TION F ILt:. NO.22-4740.

rROM TO

NOTE, R..A.............A.........

A1.,,...A....

..Au,,.....c....A,...

PARAMETER

",*/

AVERAGE M AXIMUM UNITS MINIMUM AVERAGE MAMIMUM UNITS 001 FLO4 REPORTED

                1. 4**###******

,,;f,";g.,,,

n;3D

                • c#**********
                  • c

] /pi MEA $

002 pH REPORTED *####*#e*#**##**#**#

') ~

(

..;f =,,;g.,,,

                                      • e 6.0000*********#

9.0000 SU 1/M GWB 003 3405 REPORTED

...J "'J 3.4050 5.1100 KG/D# **********

30.0000 45.0000 MG/L 1/M WA8 004 TOTAL SUS. SOLIDS REPORTED

                • e#

..JJ "."'J..,

3.4050 5.1100 AG/D 30.0000 45.0000 MG/L 1/M GRAB 005 TOTAL I

ClJ REPORTED ****##*************e

                  • 8

.. JJ.".

'J..,

1 0000 **********

2.0000 NG/L 12 1/D GPAS 165 CL2 IN5T HES(M*X)

. REPORTED ####################

..;f;;g.,,,

                  • a 4.0000 NG/L 1/D GPAS i

REPORTED

. A.";'J..,

REPORTED

.As.....,....

e..

T TOTAL F OW TOTALSOOs OPER ATOR IN RESPONSIBLE CHARGE DATE BVP ES OCC E.

AND OVERFLOWS B CERTIFY UNDER PENALTV OF LAW THAT 4 6. AVE PfRSONALLY EMAMINED AND AM

" O MIUM N E

UU MU E E U RU N M

"A" OAY F AMILIAR WITH THE GNFCRMATION SUOMITYf D sN THIS DOCUMENT AND ALL ATTACM-MENTS ANO TMAT. SASE D ON MY sNCAJiRY W THOSE INDIVIDUALS IMMFDIATELY RE.

PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE Y

s TRu AC ATE A et TE A

RE TM T E AR Ss.N F CANT PENALYaES FOR SUSMITTING F ALSE AdFORMATf0N..NCLUOtNG THE POSS BIL8-

.TV OF FINE! AND IMPRISONMENT. SEE 18 U 5. C. 51001 AND 33 u, S.C. e 1319 IPens.i-

'e unusse these steuse s may lectode. wies up o $t0,000 and/or enesunuse ^

t f 8 menebs and t year. #

TYPEO OR PRINTED N AME SIGN ATURE NUM.ER YEAR MO DAY SWCB NPDES FORM 5 PAGE Or

~

SWCB/1-80/I PART I PERMIT NO.

VA 0052451 Page 'll of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.9rge from outfall(s) serial number (s) Turbine Building Sumps 012, 013 & 014 Such discharges shall be limited and monitored by the permittee as specified below EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day Other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Avg.uDaily Max.

Frequency Type 3

Flow-M / Day (MGD)

NL NL NL NL 2/ month Estimate Total Suspended Solids NA-NA.

30 mg/l 100 mg/l

& month Grab pil& Grease NA NA 15 mg/l 20 mg/l

~2/ month Grab 2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored

'P/ month by grab sample.

  • 3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

Sump #1 report as 012, Sump #2 report as 013, Sump #3 report as 014.

yH22O.zgW<. Fz og > ggZ C ' 4H 3<HWE o0zrEO-moqgg a

I l

.g 3.5tm, )p:. *:* P. i.N:=l -

o3 t'"

MZa24bNMCJ 7e,or 0mNM&NTD 8 y ggZ<h]a.'iI<,;t3gp 24>

f33 c

=;'3 f

L i:

D*

2o

,">1; j$ 3 6j

'aI

<;is 's

  • >n3q(7u !. :sdbjJ aodf
E 5-

>wauo.

zorpI azZt 0 o J't f W>4>Mo2 t

z I=

Jr e

eo==

2cCcta4LI" cA

>1<JJw> EW0MOZ<J Oa.Lk6OW r

6 max tceco r=E> Zs2 e "

ip;;.8t Q.O.

mOx NCm n.oe e

u

.?

NMNe-Q%MOow3.eFWf x.uxc.ozo

><. NNWMN

.'on mNW N Ce l2oi

  • fo m

D' &in N

6l:! ?

'e

  • a a

oe, I

I a$<Eoz aM W 2O.NmI4N4o.

g;2

  • o t

zo5-E.::*l>jo:al '- *I3l2I

'.r: *o,jg:g-

' o. f e!=

t> o, o

  • E*

3 E= $2*

{.g:u,

'o 18t.

ihE l

0<t<2 8

  • a i !

< "E<ou 2<E 2 = 2 3gO I g232 t>

  • 4ou 3<E232 aE>w a

ocM t.

zWnombWO

    • e******e
  • $****o***
      • 0*****e

.Jo3 s

5.t 1ec
                  • e
                  • a

.n i.-

LWH ia, L

cCm a1 ewa0mHWO *******************o

                  • 4
.!. t
                  • s*********e

<ecCcc *********W OaCccu m:

nss eG<2

!3 l r, f

oo, toF a i

mon.moJMam rW.a0m>WO *********e*********o

                  • o i

!e

.! = f r,

  • 80*0**************e
                  • e "C*cccG
  • ceeecco xe%_j gsw e c.< E iCo Oe.J e

. i e

n oIm mw muaOmFWO *******************o

  • e*******o
.i.t
                            • e****o
                  • e

~U cccG Nc occc ze5i aRs le<1 j

l, i

o o

aWaomHWO I,

gr.I$

i l

eWa.oelWO

  • !i
.!. e l e, mwa0eFWO
  • li
.l. t l,

mWa0m8WO

r. I e,

)

4:eo, I.i = = s

.t. : v5a.y.

ug==J=, >o,yd -

~* o-g*<

Eaog

  • o$ J 'OcI O.,

kO2 ~Z *we0zb.ay UIt'ao, O<$

.>2mm:

O r,a

,o>weu3 =e r;waog g *>waz<2w "2z <$ e W uwl c5*w zd

>w 2o 8">

3,gc: $qG,no:!:e,!s g E "r.r$W$ *2i3oh{o !

v Bs,;t;z "r

g E=;<

gif g y1<a Uwu3;>w ot $e o= 4s>E"-

wo 4, z>

  • Jwgozw o<l o;

,3n5 ct r 3a;3g.8. s,I "7 *d5.g;,,5.Ed,!H o 5 =,1s; x

g 8<

5o

"'.E s2rd0 o

v8r.., *s

  • f *Q35,
.$ii
  • E gp [ d. ! inpr;*g ',g o
  • g go 2 s. oy $is 5gj ga !dia.lI !ri! gj =1 e ' *gg la ls{
    • r=

e i

g jis.gI6

  • ,[.

,;uaot g *>w0z<2u "2z < j e W i 38wa

>wc" Io 0I">

  • ge
  • g.

g:o: zAo$ uO0s u

!0w oh o

s e

COMMONWEALTH OF VIROINI A CTATE WATER CONTROL BOARD i.

P aw,64,m,. A te.,....,.,P 6...

u..,....-...

m.,. e). x i INDUSTRIAL MAJOR 03/19/95

/b. 49.e tP P...,)

DBSCH Ae.W MONITWING,.EPO-T (DMN t

ST A T E W A.T.E..R C..O.N.T.R..O.L SO A R D i.

VEPCO-NORTH ANNA POWER STATION NAME ADDRESS VA0052451 013 VALLEY REGIONAL OFFICE P.O. SCX 26666 PERM'TNuM.ER

"'c::an=

P.O. 80X 268 RICHMOND Vt 23261 BRIDGEWATER, Va. 22812 rACluTv 703-828-2595 LOC ATio N FILE NO.22-4740.

rROM TO

NOTE, R......,,.......,...

...........-T.....

PARAMETER

"*/

""""l-AVERAGE M AXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 FLOA REPORTED

. 0,",;;.,,,

t1GC 2/M EST 002 pH REPORTED ##**###**#########**

Y'

,,.0,",:g.,,,

                          1. o******

6.0000 **********

9.0000 SU 2/M GRAR 004 TOTAL SUS.SOLIOS REPORTED **##*###*****#***###

..."=,,; g.,,,

30.0000 100.0000 MG/L 2/M GoAB 500 CIL &

GRETSE REPORTED *****#*********###**

. 0".17.,

15.0000 20.0000 MG/L 2/M GRA8 REPORTED

. 0,":2.,

REPORTED REPORTED

. 0,":...

REPORTED se.

..e.s,

... es. se, e

.lve..

6 c..ees,.......es..T.....eene.es,.

BYPASSES OCCURRENCES G

(

G 4

AND OVERFLOWS 9 CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EltAMINED AND AM TYPED OR PRINTED N AME SIG N ATU P E CERTIFIC ATE NO.

VEAR MO DAY F AMILI AR WITH THE INFCRMATION EUBMITTED IN THIS DOCUMENT AND ALL ATTACH.

MENTS AND THAT, BASED ON MV INQUIRY OF THOSE INDivlDUALS IMMEDI ATELY RE.

PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE DATE SPO.NSIBLE FOR OST AITNG THE INFORMATION 0 SELIEVE THE SUBMITTED INFORMA-TOO t IS TRUk, ACCUF6 ATE AND COMPLETE. AM AWARE THAT THERE ARE SIGNIFB-CANY PENALYsES FOR SUBMITYtNG F ALSE,NFORMATION.,NCLUDING THE POSS18tLf-TV OF FINE AND tWPRISONMENT. SEE C

Des e,nder these statutes eney enctode tone,IS U. S. C. S 9001 AND 3J U S.no '. 61319 IPenal-up to $10.000 and/or eneswsu

. of 6 snanthe yd t yearsJ TYPED OR PRINTED N AME SIGN ATURE "U"

M UM BER YEAR MO DAY SWCB NPDES FORM 5 PAGE Or e

COMM'INWEALTH OF VIR'JINI A CTATE WATER CONTROL COARD

".""'""e? ""."a"fMMJ'".?,"*'. v

""'*"stSi*.u"21"Ja'u"GOliya";"3' "#GM"R'i" ' * " '

INDUSTRIAL MAJOR 03/19/85 8

LT AT3 WME 2 Cr NTGC L BO A7D insosoveAh errocal VEPCO-AGRTH ANNA POWER STATION NAME r.oo R E SS v h 0 0 5 P 4 c,1 014 VALLEY REGIONAL 0FFICE P.O. BOX 26666

= "":"

P.O. BOX 2iS8 RICWOND VA 23261 BRIDGEWATER, VA. 229]2

,vo...e....

703-828-2595 rACiuTv A-A-

A-

-A-FILE NO.22-4740.

LOC ATION NOTE.

R. A.

-.T.A

. e A 6 s, o e r..-.

........6.e..s.

eU AnvIrv 04 LOAS48ee ew A6syv OR CeseC Esev4 AveON

...e

.y PA R A M ETE R

"*/

" "" *1" AVERAGE M AXIM UM UNITS MINIMUM AVERAGE MAXIMUM UNITS 001 REPORTED

                  • e *********e
                  • e
ptg,

.. l"""'J..?

MGn

                  • e 2/M c9T 002 g

pq REPORTED *******************e U

.. l",""'J..,

os******************

.A.nnnn **********

o.nnno SU P/M c-p a R 004 TOTAL SUS.SOLIOS REPORTED ********************

..e'.",","'J.,

  • 4**s***4*** sus ***se v **********

30.0000 10 M 000 MG/L P/M

'; eta 500 OIL &

GREASE REPORTED ********************

..eo",","'..?

  • s****************s*

1%0000 20.0000 M n /t_

2/M noaq J

REPORTED es e nsar as even u meeny REPORTED p e o ne s, ne even s muser REPORTED es sees sy m aeuen s es==v REPORTED re n essy a meuse m an essy hoosysomeA6 Pennesy maeusannesesvs on cosensumvs TO T A L-TOTAL FLOW TOTALBODs OPERATOR IN RESPONSIBLE CH ARGE DATE BYPASSES OCC U R R E NC ES l M. G. )

lK G )

AND

' OVERFLOWS TYPED OR PRINTED N AME SIGN ATU R E CERTIFIC ATE NO.

VEAR MO DAY t CERTIFY UNDFR PENALTY OF LAW THAT 8 HAVE PERSONALLY EM AMINED AND AM M T5ANOTMAY E D ON IN U OSE De S IMMED AT y PRINCIPAL EXECUTIVE OFFICER OR AUTNORIZED AGENT TELEPHONE DATE SPONSISLE F OR 08 T AINING T HE INFORMATION 4 SE LIEVE TME SUBMITTED eNFORMA-YtON IS TRUE. ACCUR ATE AND COMPLETE. I AM AWARE THAT THERE ARE StGNIFI-CANT PEN ALTtES FOR SUBMITTING F ALSE 6NFORM ATION. INCLUDING THE POSS181LI-TV OF FINE AND IMPRISONMENT SE E 18 U. S C. t 1001 AND 33 U 5 C. t 1319 treaal-ties under these seetwees may Whade fmee up to $10.000 and/or enenwnurn impmaaraent of we e mones and t e s TYPED OR PRINTED N AME SIGN ATURE NUMBER YEAR MO DAY SWCB NPDES FORM S PAGE Or

=

SWCB/1-80/I PART I PERMIT NO.

VA 0052451 Page 12 of 18 A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS I

1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to discherge from outfall(s) serial number (s) Bearing cooling tower Blowdown-015 Such discharges shall be limited and monitored by the permittee as specified below EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORINC REQUIREMENTS kg/ day Other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Ayg., Daily Max.

Frequency Type 3

Flow-M / Day (MGD)

NL NL NL NL 1/ month Estima te Chlorine NL NL NL NL 1/ month Grab h

1 i

i l

2.

The discharge shall have a pH value between 6.0 and 9.0 at all times and shall be monitored 1/ month by grab sample.

3.

There shall be no discharge of floating solids or visible foam in other than trace amounts, 4.

j' Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

prior to mixing with flow in discharge canal.

CEMMONWEALTH OF VIRGINIA STATE WATER CONTROL BOARD

'i";','Z** ".:."A!,at*,%:'J'",%?.b,i

"""*"d,'SF,u"Ji"E' A'; ;n;T;i NT'"J'"H'EJ,4"'*2d INDUSTRIAL MAJOR 0V19/85 STATE W A.T.E..R C. O.N.T.R..O.L BO A R D i.

VEPCO.h0RTH ANNA POWER STATION NAME ADDRESS VA0052451 015 VALLEY REGIONAL OFFICE P.O. BOX 26666

"<a"'T nuM.ER

';::::::=

P.O. BOX 268 RICHMOND V%

23261 BRIDGEWATER, VA. 22812 703-828-2595 rAciuTV FILE NO.22-4740.

LOC ATlON rROM TO

NOTE, R.

PARAMETER

  • ^ " ' ' '

o.

AVERAGE M AXIMUM UNITS.

MINIMUM AVERACE M AXIMUM -

UNITS 001 FI,QW REPORTED

'GD 1/f t E51 i

002 3

PH REPORTED

' y'

. 0,a,;g.,,,

-6.0000**********

9.0000 SU 1/M GRAB 005 TOTAL 3

CL2 REPORTED **######*********#**

,,..'=,, ; g.,,,

MG/L 1/M GoAB REPORTED

....e.,

REPORTED REPORTED

...'.","."'J.,

REPORTED REPORTED i

a...,...

\\

i T T A R. BOD.

OPERATOR IN RESPONSIBLE CH ARGE DATE BYPASSES O.CU CE.

G (M

AND

, OVERFLOWS 1

4 CERTIFY UNDER PENALTY OF LAW THAT, HAVE PERSONALLY EXAMINED AND AM TYPED OR PRINTED N AME SIGN ATU RE CERTIFIC ATE NO.

YEAR MO DAY M TS AND THA AE ON Y R

OSE D S IMME AT y PRINCIPAL EMECUTIVE OrFICER OR AUTHORIZED AGENT TELEPHGNE DATE SPONS, ISLE FOR OBTAINING THE INFOR%,ATsO CANT PE,NALTIES FOR SUBMITTING F AL,SE

,N t SELIEVE THE SUSueTTED INFORMA-TION $ TRUE, ACCUR ATE AND COMPLETE AM AWARE THAT THERE ARE SIGNIFI-NFORMATION. INCLUDING THE POSSIBILt-TV OF F NE AND IMPRISONMEN f.,SEEmes u.U. S. C. 9 1001 AND 33 U. S. C. e 1319. (Penal-8 eo $10,000 andnor momemwn impnsomment of time awuser i,m sesivies mey incsude e mnam end $ veers )

TYPED OR PRINTED N AME SIGN ATURE NUMBER YEAR MO DAY SWCB NPDES FORM 5 PAGE OF

SWCB/1-80/I PART I PERMIT NO.

VA 0052451 Page 13 of 18 a

A.

EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS 1.

During the period beginning with the permit's effective date and lasting until the permit's expiration date, the permittee is authorized to disch.c.rge from outfall(s) serial number (s) Intake screen wash water 016 Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CHARACTERISTIC DISCHARGE LIMITATIONS MONITORING REQUIREMENTS kg/ day Other Units (Specify)

Measurement Sample Monthly Avg. Daily Max.

Monthly Av'g. Daily Max.

Frequency Type 3

Flow-M / Day (MCD) 7,.-

5:'

The only authorized discharge from this outfall is intake screen wash water.

No monitoring or reporting is required.

i i

a j

j 2.

The discharge shall have a pH value between 6.0 and 9 D at all times and shall be monitored N/A 3.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

j 4.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s):

N/A

h5 l

~

a

?

%lll"@g/

=

gy 1/C

\\

4 n

W 4 e y) m' p

Ir' v4 2

W f

4 N

% b m : e. 4 ec el s

a 4 %x;

!! /

hw e

f s4 E

CD C

=;

~~

f j'

~n

=

L.

2 is e

ce

?

?

E

(

C W~

)

.b Y

~)[?

1 E

C i

Jv 5

)L

/

~

s 9

~ ' ' ~. _. _

'W,

.e.-

?

g:

a 5

E sa b I Oz Po f

et e

W W

8

<-1 S

l l

4 e

.g e 2

=.

A s L

=<

Jw

=<m3 a88 A2

/

l,

)

Es

'm e-j H<

2 k2 C<

I :

mw 2M C<

b l'

LM 1

u C2 ACw G'

b, b6 sge

.: t.:

"2 >

LO

<w l

i n

E

?

=I" x

O e

a

/

w i

i i

~

M

Permit No. VA 0052451 N, orth Anna Page 14 of 18 Special Conditions: Effective Immediately Unless Otherwise Specified 1.

Debris collected on the intake trash racks shall not be returned to the waterway.

2.

There shall be no discharge of polychlorinated biphenyl transformer fluids to navigable waters that originate from this source in amounts equal to or greater than detected by EPA Test Methods specified in the Federal Register 40 CFR Part 136, Guidelines for Establishing Test Procedures for the Analysis for Pollutants.

3.

All limitations and monitoring requirements for liquid radioactive waste discharges shall be regulated by the Nuclear Regulatory Commission in accordance with regula-tions as set forth in 10 CFR part 20 and 10 CFR part 50.

4.

The permittee has requested alternative effluent limitations under Section 316(a).

VEPC0 will conduct a 316(a) study and will submit a demonstration report on the study. The Board approved 316(a) study plan was implemented on 1 January 1984 and shall be concluded within two years of implementation. Within 3 months of the completion of the 316(a) study, VEPC0 shall submit a. draft final report to the Board. During the 316(a) study, should serio~us adverse impacts develop as a result of the thermal discharge, the Board reserves the right to reopen and modify the permit as expressed in Part III.B.4 or as deemed necessary to assure adequate pro-tection of the biota in Lake Anna and the North Anna River.

5.

The permittee shall at all times provide minimum instantaneous release from the impoundment of at least 40 cfs.

6.

The findings of fact and conditions set forth' in the 401 CertiIicates issued by the Board on August 29, 1973, and the 21(b) certificate as amended on February 11, 1972, are incorporated herein by reference as limitations and shall continue in full force and effect.

These certificates may be revised in the future. Upon the completion of any amendments, the revised certificates shall be incorporated herein by reference as specified above.

7.

In the event final water quality standards revisions are approved, the permit shall be modified by the Board or upon the request of the applicant to reflect the require-ments of any such changed standards.

8.

The permittee shall prepare a report which summarizes the impingement and entrain-ment information collected from the initiation of commercial operation of Unit 1 through December 31,1983, inclusive. After the summary report has been reviewed by the Board, the permittee will be notified of the conclusions and whether or not the Board believes that the permittee should submit a plan to reduce the number of fish, eggs and larvae entrained or impinged. A modified impingement and entrain-ment study may also be required as a result of the review of the Summary Report and/or the remedial action, if any is deemed necessary.

9.

Temperature monitoring program shall be done on a schedule as listed below and -

identified in accordance with accompanying Charts #1 and #2, except for the period l

of time during which the 316(a) demonstration is being conducted.

I f

f E

e, North Anna Permit Number VA 0052451 Page 15 of 18 s

Special Conditions continued:

Page 2 A.

Fixed Continuous Temperature Recorders as noted on Chart #1.

1.

Temperature measurements are to be taken hourly at surface, mid depth and bottom at Stations 1, 3, 4, 5, & 6, at a depth of 3 meters at Station 10 and at the surface only at Stations 2, 7, 8, 9, 11.and 12.

2.

Report temperature readings as listed below:

a.

Monthly maximum daily temperature in degrees celsius, b.

Mean of daily high, mean and low values in degrees celsius, c.

Reports are to be submitted quarterly within 90 days of the end of the quarter.

B.

Quarterly Thermal Plume Survey Network as noted on Chart #2.

1.

Temperature measurements are to be taken during daylight hours from the surface to the bottom at meter intervals at Stations A through N on Chart #2.

10. The permittee shall provide notification 'to the Board prior to the use of chlorine or other biocide for any purpose other,than disinfection at the sewage treatment plants.
11. This permit may be modified or alternatively revoked and reissued to comply with any standard or limitation which results from the recommendations of the Disinfection Task Force.
12. Semiannual toxicity tests shall be conducted on outfall 011 using Daphnia palex and fathead minnow, Pimephales promelas.

The Daphnia test shall be a 48-hour static test and the fathead minnow test shall be a 96-hour static test, both conducted in such a manner and at sufficient dilutions for calculation of a valid LC50.

If a test results in an LC50 of less than 100%, then further toxicity testing may be required. Technical assistance in developing the pro-cedures for these tests shall be provided by the State Water Control Board staff and all procedures shall be approved by the staff.

13.. Annual toxicity tests shall be conducted on outfall 010 using Daphnia puler and the fathead minnow, Pimephales promeZas.

The Daphnia test shall be a 48-hour static test and the fathead minnow test shall be a 96-hour static test, both conducted in such a manner and at sufficient dilutions for calculation of a valid LC50.

If a test results in an LC50 or less than 100%, then further tox-icity. testing may be required. Technical assistance in developing the pro-cedures for these tests shall be provided by the SUCB staff, and all procedures shall be approved by the staff.

i

North' Anna' Permit Number VA 0052451 Page 16 of 18 i.-

Special~ Conditions' continued:

E'

.l'4.'~The results of these studies shall be submitted upon completion and no later-

-than with the DMR of-the month endingithe calendar quarter in which the studies l

were conducted.. Bioassay results shall' be reported on the " Data Sheet for i.

Effluent Toxicity Test" found on page 33 of publication EPA 600/4-78-012.

TAdditional data or comments may be attached.

'15.

At the end of two' years, the program will be ~ evaluated with a view toward con-tinuation, modification or. elimination. Any modification must be done.in accordance with the Virginia State Water Control Board's Statutes, Regulations, i

Policies and other Documents Manual; Regulation 6.

t l

f :

j

.~

~

a 4-

PART II

~

PERMIT NO.

VA 0052451 Page 1 of 4 A.

Monitoring and Reporting 1.

Sampling and Analysis Methods Samples and measurements taken as required herein shall be representative a.

of the volume and nature of the monitored discharge, b.

The sampling and analysis program to demonstrate compliance with the permit shall conform to Part I of this permit.

The permittee shall periodically calibrate and perform maintenance c.

procedures on all monitoring and analytical instrumentation at intervals that will insure accuracy of measurements.

2.

Test Procedures Test procedures for the analysis of pollutants shall conform to the applicable test procedures identified in 40 C.F.R. Part 136 unless otherwise specified in this permit.

3.

Recording of Results For each measurement or sample taken pursuant to the requirements of this permit, the permittee shall record the following information:

a.- The date, exact place and time of sampling or measurements; b.

The person (s) who performed the sampling gr measurements; The dates analyses were performed; c.

d.

The person (s) who performed each analysis; The analytical techniques or methods used; and e.

f.

The results of such analyses and measurements.

4.

Records Retention All records and information resulting from the monitoring activities required by this permit including all records of analyses performed and calibration and maintenance of instrumentation and recording from continuous monitoring instrumentation shall be retained for three (3) years. This period of retention shall be extended automatically during the course of any unresolved litigation regarding the regulated activity or regarding control standards applicable to the permittee, or as requested by the Board, 1

1

r PART LI PERMIT NO.

VA 0052451 Paga 2 cf 4 5.

Additional Monitoring by Permittee

~ If the permittee monitors any pollutant at the location (s) designated herein more frequently than required by this permit, using approved l

analytical methods as specified above, the results of such monitoring shall be included in the calculation and reporting of the values required in the Discharge Monitoring Report (DMR). Such increased frequency shall also be indicated.

6.

Water Quality Monitoring The Board may require every owner to furnish such plans, specifications, or other pertinent information as may be necessary to determine the effect of the discharge on the water quality or such information as may be necesgary to accomplish the purposes of the State Water Control Law or Clean Water Act.

The permittee shall obtain and record such information on the receiving waters as requested by the Board. Such information shall be subject to inspection by authe-ized State and Federal representatives and shall be submitted with such frequency and in such detail as requested by the Board.

7.

Reporting Requirements a.

If, for any reason, the permittee does not comply with any maximum daily or average weekly discharg.e limitations or standards specified

[

in this permit, the permittee shall submit to the Board with the DMR at least the following information:

(1) A description of the discharge and"cause of noncompliance; (2) The period of noncompliance, including exact dates and times and/or the anticipated time when the discharge will return to compliance; and (3) Actions taken or to be taken to reduce, eliminate, and prevent l

recurrence of the noncomplying discharge.

l b.

In the case of any discharge subject to any applicable toxic pollutant i

effluent standard under Section 307(a) of the Act, the information required in paragraph (a) regarding a violation of such standard shall be provided immediately, that is as quickly as possible upon discovery.

If this information is provided orally, a written sub-mission covering these points shall be provided within five days i

l of the time the permittee becomes aware of the circumstances covered

(

by this paragraph.

c.

In the case of other discharges which could constitute a threat to human health, welfare, or the environment or are considered to be unusual or extraordinary

  • discharges pursuant to the Board's Regulatic n No. 4, the infomation required in paragraph (a) shall be provided immediately, that is as quickly as possible upon discovery.

If this information is provided orally, a written submission covering these points must be provided within five days of the time the permittee becomes aware of the circumstances covered by this paragraph.

Part II PERMIT NO. VA 0052451 Page 3 of 4

  • Unusual or extraordinary discharges would include but not be limited to any discharge of waste resulting from (1) spillage of materials resulting directly or indirectly from the owner's processing opera-tions, (2) breakdown of processing or accessory equipment, (3) fail-ure of or taking out of service, sewage or industrial waste treatment facilities or auxiliary facilities, or (4) flooding or other acts of nature.

If the Regional Office cannot be reached, the Board maintains a 24-hour telephone service in Richmond, telephone number 804/257-0080 to which the report required in (b) and (c) above are to be made.

d.

Pollutants for which the permittee must report violtaions immediately pursuant to (b) and (c) are listed as such in this permit in Part I(A).

e.

The permittee shall submit to the State Water Control Board Regional Office, at the address listed below, by the 10th of each month an original of the National Pollutant Discharge Elimination System Dis-charge Monitoring Report of the facility's performance in accordance with Part I.A.

In addition, a monthly report covering the facility's general operational data may be required.

(An original of each month's report to:)

State Water Ccnirol Board Volley Regienal 03 ice 11G North Main St:act P. O. Box 263 Bridgewater, Virginia 22s12 8.

Before utilizing the services of any person or commercial laboratory as defined in Section 6.45 of the Board's Regulation 6 to perform any permit monitoring requirement, the permittee shall comply with the pro-visions of Section 6.45(b) of the Regulation 6 and submit a copy of any contract made to the Board.

B.

Definitions Unless otherwise stated here, the definitions of Regulation #6 apply 1.

The " average monthly discharge" is the total mass, and concentration in the case of sewage' treatment works, of all daily discharges sampled and/or measured during a calendar month on which daily discharges are sampled and measured, divided by the number of daily discharges sampled and/or measured during any such month. The average monthly discharge limitation may not be violated during such calendar month.

2.

The " average monthly temperature" means the arithmetic mean of measure-ments made on an hourly basis, or the mean value plot of the record of a continuous automated temperature recording instrument, either during a calendar month, or during the operating month if flows are of shorter duration.

J '. -

PART 11 PERMIT NO.

VA 0052451 Peg 3 4 cf 4 3.

The " maximum daily discharge" is the highest total mass of a pollutant discharged during the calendar day or, in the case of a pollutant limited in terms other than mass, the highest average concentration or other measurement of the pollutant specified during the ' calendar day or any 24-hour' period that reasonably represents the calendar day for the purposes of sampling.. The maximum daily discharge limitation may not be violated during any calendar day.

4.

The " average weekly discharge" is the total mass and concentration of all daily. sewage treatment works discharges during any calendar week on which 7

daily discharges are sampled and/or measured divided by the number of daily discharges sampled and/or measured during such calendar week. The average weekly discharge limitation may not be violated during any calendar week.

5.

" Bypass" means the intentional diversion of wastes from any portion of a treatment facility as defined in Section 6.14(m) of Regulation #6.

'6.

" Upset" means an exceptional incident in which there is unintentional and temporary noncompliance with technology-based permit effluent limita-tions because of factors beyond the reasonable control of the permittee as defined in Section 6.14(n) of Regulation #6.

7.

" Composite Sample" means a combination of individual samples taken at selected intervals to minimize the effect of the variability of the individual samples.

8.

" Grab Sample" is an individual samp e collected in less than 15 minutes.

9.

"i-s" (immersion stabilization) means the.isnmersion of a calibrated device in the ef fluent stream until the reading is. stabilized.

10.

The " maximum daily temperature" means the highest arithmetic mean of the temperature observed for any two (2) consecutive hours during a 24-hour day, or during the operating day if flows are of shorter duration.

11.

" Measured flow" - any method of liquid volume measurement the accuracy of which has been previously demonstrated in engineering practice, or for which a relationship to absolute volume has been obtained.

12.

"At outfall XXX" - A sampling location in outfall line XXX downstream from the last addition point or as otherwise specified.

13.

" Estimate" is to be based on a technical evaluation of the sources con-tributing to the discharge including, but not limited to pump capabilities, water meters and batch discharge volumes.

14.

"NL" means no limitations on the affected parameters, however, monitoring is required.

15.

"NA" means effluent limitations and monitoring requirements not required.

16.

"Non-contact cooling water" means water used to reduce temperature which does not come into direct contact with any raw material, intermediate product, waste product (other than heat), or finished product.

PART IL1 PERMIT NO.

VA 0052451 Pags 1 of 6

  • A." Management Requirements 1.

Change in Discharge All discharges authorized by this NPDES permit shall be made in accordance with the terms and conditions of the permit. All expansions, production increases, or process modification., that will result in new or increased s

discharge (s) of pollutants, must be reported promptly to the Board by submission of a new NPDES application, or, if such discharge (s) does not violate effluent limitations specified in the NPDES permit, by submission to the Board of notice of such new or increased discharge (s) of pollutants.

The discharge of any pollutant more frequently than, or at a level greater than that identified and authorized by this permit, shall constitute a violation of the terms and conditions of this permit.

If this permit is for a discharge from a treatment works that receives waste from an owner other than the permittee, the permittee shall promptly provide notice to the Board of the following:

Any new introduction of pollutants into such treatment works from a.

an establishment, treatment works, or discharge (s) which would be a new source, as defined in this permit, if such source were dis-charging pollutants to State waters.

b.

Any new introduction of any pollutant (s) into such treatment works, which introduction represents a significant increase in the discharge of pollutant (s) to the treat. ment works or may interfere with, pass through, or otherwise be incompatible with such works, from an establishment, treatment works, or. discharge (s), if such establish-mant, treatment works, or discharge (s) were discharging pollutants to State waters; and,

. ]

Any substantial change, whether permanent or temporary, in the c.

volume or character of pollutants being introduced into such treat-ment works by an establishment, treatment works, or discharge (s) that was introducing pollutants into such treatment works at the time of issuance of the permit.

Such notice shall include information on:

(1) the characteristics and quantity of effluent to be introduced into such treatment works; (2) any anticipated impact of such change in the quantity of characteristics of I

effluent to be discharged from such treatment works; and (3) any additional information that may be required by the Board.

Any owner proposing a new discharge or new source shall submit an application for a NPDES permit at least 30 days prior to commencing erection, con-struction, or expansion or employment of new processes at any facility.

Within that 30 day period, the Board may prohibit such commencement until the NPDES permit is issued. In no case, however, shall any discharge from said facilities commence prior to the issuance of a NPDES permit.

l l

PART IL1 PERMIT.NO. VA 0052451 Page 2 of 6_

i i

+

r E2.

Treatment Works Operation and Quality Control i

All waste collection, control, treatment and. disposal facilities shall be operated in a manner consistent with the following:.

a.

At all times,_all facilities shall be operated in accordance with the CTO, if applicable, and in a prudent and workman-like manner so as.

to minimize upsets and discharges of excessive pollutants.

b. ' The permittee shall provide an adequate ' operating staff which is duly qualified to carry out the operation, maintenance and testing functions required to insure compliance with the conditions of this permit.

c.

Maintenance of treatment facilities shall be carried out in such a manner that effluent quality requirements are not violated.

d.

Collected residues shall be stored in such a manner as to prevent entry of those wastes (or runoff from the wastes) into State waters, and disposed of in accordance with this permit or other Certificate issued or plans approved by the Board.

3.

Adverse Impact The permittee shall take all feasible steps to minimize any adverse impact to State waters resulting from noncompliance with any effluent limitations specified in this permit, and shall perform and report such accelerated or additional monitoring as is necessary to determine the nature and impact of the noncomplying discharge.

~

4.

Treatment Facilities Failure In order to maintain compliance with the effluent limitations and prohibi-3-

tions of this permit, the permittee shall:

a.

In accordance with the Schedule of Compliance contained in Part I, or in accordance with the Virginia Sewerage Regulations, if applicable, provide an alternative power source suf ficient to operate the waste-water collection and treatment facilities; or, if no date for implementation appears in Part I, and the Virginia Sewerage Regulations do not apply, b.

Halt, reduce or otherwise control all discharges upon the reduction, loss, or failure of the primary sources of power to the wastewater collection and treatment facilities.

c.

Halt, reduce or otherwise control all discharges upon the reduction, loss, or failure of the treatment facility until the facility is restored or an alternative method or treatment is provided.

e

PART 111 PERMIT NO.

VA 0052451 P4gs 3 of 6

'S Structural Stability

.C l

The structural stability of any of the units or parts of the facilities herein permitted is the sole responsibility of the permittee and the failure of such structural units or parts shall not relieve the permittee of the responsibility of complying with all terms and conditions of this permit.

6.

Bypassing Any bypass of the treatment facilities herein permitted is prohibited unless:

the bypass is unavoidable to prevent a loss of life, personal injury, a.

or severe property damage; and b.

there are no feasible alternatives to bypass, such as the use of auxiliary treatment facilities, retention of untreated waste facility shutdowns or maintenance during normal periods of equipment down time; and c.

The Board is notified immediately, and as quickly as possible upon discovery of the bypass (if orally notified, then followed by a written submission within five (5) days). Where the need for a bypass is known (or should have been known) in advance, this noti-fication shall be submitted to the Board for approval, if possible, at least ten (10) days before the date of bypass; and

~

d.

the bypass occurs under conditions determined by the Board to be necessary to minimize adverse effect.,The public shall be notified and given an opportunity to cor.nent on' bypass incidents of significant duration, to the extent feasible.

7.

Conditions Necessary to Demonstration of an Upset An upset shall constitute an af firmative defense to an action brought for noncompliance with technology-based effluent limitations only if the permittee demonstrates, through properly signed, contemporaneous operating logs, or other relevant evidence, that; a.

an upset occurred and that the permittee can identify the specific cause(s) of the

' set; and b.

the facility permitted herein was at the time being operated in a prudent and workman-like manner and in compliance with proper operation and maintenance procedures; and c.

the permittee submitted a notification of noncompliance as required by Part II.A.7 above; and l

l d.

the permittee took any measures necessary to minimize adverse impact to State waters.

m.

3 PART ILL-PERMIT NO. VA 0052451 Pzg2 4 cf 6

~

8.

State Law Compliance with this permit during its term constitutes compliance with the Law and Act except for any standard imposed under Section 307 of the Act for a toxic pollutant injurious to human health.

~

Nothing in' this permit shall be construed to preclude the institution of any legal action under, or relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any other State law or regulation or under cuthority preserved by Section 510 of the Act.

9.

Property Rights The issuance of this permit does not convey any property rights in either real or personal property, or any exc'lusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement'of Federal, State, or local laws or regula-tions.

10.

Severability The provisions of this permit are severable, and if any provision of this permit, or the application of any provision of this permit to any circum-stance, is held invalid, the application of such provision to other circumstances, and the remainder of this permit, shall not be af f ected thereby.

11.

Reapplication for a Permit At least 180 days before the expiration date of this permit, unless permis-sion for a later date has been granted by. the board, the permittee shall submit a new application for a permit.

B.

Responsibilities 1.

Right of Entry The permittee shall allow authorized State and Federal representatives, upon the presentation of credentials:

a.

to enter upon the permittee's premises on which the establishment, treatment works, or discharge (s) is located or in which any records are required to be kept under the terms and conditions of this permit; b.

to have access to and copy at reasonable times any records required to be kept under the teres and conditions of this permit; c.

to inspect at reasonable times any monitoring equipment or monitoring method required in this permit; d.

to sample at reasonable times any discharge of pollutants; and, b

^

o' PART 111 PERMIT NO VA 0052451 Paga 5 cf 6 to inspect at reasonable times any collection, treatment, pollution e.

management or discharge facilities required under this permit.

f.

For purposes of this section, the time for in,spection shall be deemed reasonable during regular business hours or whenever.the facility is discharging. Nothing contained herein shall make an inspection time unreasonable during an emergency.

2.

Transferability of Permits This permit may be transferred to another person by a permittee if:

a.

(1) the permittee notifies the Board, in writing, at least 60 days prior to the proposed transfer; (2) a written agreement signed by a11' parties to the transfer, con-taining a specific date for transfer of permit responsibility and coverage between the current and new permittees (including acknowledgement that the existing permittee is liable for viola-tions up to that date, and that the new permittee is liable for violations from that date on) is submitted to the Board; and (3) the Board within 30 days does not notify the current permittee and the new permittee of its intent to modify, revoke and reissue, or terminate the permit or to require that a new application be filed rather than agreeing to the transfer of the permit.

b.

Such a transferred permit shall, as of the date of the transfer, be as fully effective as if it had been is, sued directly to the new permittee.

n.

3.

Availability of Reports All reports pertaining to this permit shall be available to the public.

The Board shall not at any time disclose to any person other than appro-priate officials of the EPA pursuant to the requirements of the Act any secret formulae, secret processes, or secret methods, properly identified and denoted as such, however, other than effluent data used by any owner or under that owner's direction. Such trade secrets transmitted by the Board to EPA will be subject to appropriate Federai rei;ulations governing confidentiality of such information.

4.

Permit Modification and Revocation In accordance with the Board's Regulation 6, this permit may be modified or revoked in whole or in part during its term for cause including, but not limited to, the following:

violation of any terms or conditions of this permit; a.

b.

obtaining this permit by misrepresentation or failure to disclose fully all relevant facts; a change in any condition that requires either a temporary or permanent c.

reduction or elimination of the permitted discharge; or

o PART lil PERMIT NO. VA 0052451

$ ^

Prg3 6 of 6 d.

information that the permitted discharge poses a threat to human health or welfare.

5.

Toxic Pollutants Notwithstanding Part III.B.4 above', if a toxic effluent standard or pro-hibition (including any schedule of compliance specified in such effluent standard or prohibition) is established under Section 307(a) of the Act for a toxic pollutant which is present in the discharge and such standard or prohibition is more stringent than any limitations for such pollutant in this permit, this permit shall be revoked and reissued or modified in accordance with the toxic effluent standard or prohibition and Section 62.1-44.15(5) of the Code of Virginia. Any effluent standard or pro-hibition established under Section 307(a) for a toxic pollutant injurious to human health is effective and enforceable by the time set forth in the promulgated standard, even absent permit modification.

6.

Civil and Criminal Liability Except as provided in permit conditions on " bypassing" (Part III A-6),

" upset" (Part III A-7) and " treatment facilities failure" (Part III A-4),

nothing in this permit shall be construed to relieve the permittee from civil and criminal penalties for noncompliance.

7.

Oil and Hazardous substance Liability Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or penalties to which the permittee is or may be subject under Section 311 of the Act or Sections 62,.1-44.34(1) through 62.1-44.34(7) of the Law.

t l

I l

O o

MEMOilANDUM

      • * # 4 2/9 4 State Water Control Board 2111 North Hamilton Street P. O. Box 11143 Richmond, VA. 23230

SUBJECT:

Reissuance VA 0052451, VEPC0 and Old Dominion Electric Cooperative North Anna Power Station, Mineral, Virginia - Louisa County TO:

Executive Director FROM :

Assistant Director of Operations ofWatekResourcesManagement DATE:

18 March 1985 COPIES:

VR0 File #22-4740 Legal Name of Owner:

VEPC0 & Old Dominion Electric Cooperative Application Submitted By:

VEPC0 Application Date:

Initial submission dated 7 December 1981 and the additional information submitted as a supplement to this application.

Type of Discharge:

Existing Industrial Discharge.

Manufacturing Operation:

The industry is involved in the production of (Sic Code 4911) electricity by the fission of nuclear materials.

Wastewater Treatment Facilities:

The sixteen permitted discharge points have a variety of treatments. The sanitary wastes are treated by extended aeration STP's. The industrial wastes are treated by clarifiers, settling sumps, oil / water separators and/or cooling ponds.

Receiving Stream:

Stream:

Lake Anna and North Anna River Basin:

York Subbasin: None Section:

3 Class:

III Special Standard (!,):

none Public Notice:

The application has received public notice in accordance with Regulation #6 and no response was received.

Planning:

The discharge is in conformance with the York River Basin Water Quality Management Plan.

EPA Comments:

EPA has no objections to the adequacy of the draft permit, but did offer several comments about the draf t pennit. One comment concerned a typographical error which has been corrected. The balance of EPA's comments and the staff's rationale for maintaining the draft permit as proposed were discussed with EPA and verbally approved. There remain no unresolved objections by EPA.

, 'a O

,Roissuanc? VA 0052451, VEPC0 and Old Dominion Electric Cooperative - North Anna 18 March 1985 Page 2 c-Corps of Engineers Comments:

The COE offered no comments concerning the adequacy of the draft permit.

Previous Board Action:

There has been no previous Board action with respect to this reissuance.

Staff Comments:

NPDES Permit No. VA 0052451 was issued on 2 June 1977 and expired on 2 June 1982. The terms and conditions of the permit were administratively continued follow-ing expiration.

The permit reissuance process was delayed by numerous revisions to the draft permit, the Toxicant Monitor-ing Program, the 316(a) study requirements and due to EPA's failure to accept the staff's concentration effluent limitations or provide their rationale for requiring mass based effluent limitations. Additional delays were created by a one-third reduction of regional manpower since March 1984.

The discharge is not controversial and is currently meeting the.Lrequired effluent limitations.

The effluent limitations for pH are based on Water Quality Standards while the balance of the parameters are based on Federal Effluent Guidelines.

The staff believes that the attached effluent limita-tions will maintain the Water Quality Standards adopted by the Board.

Certified Operator The staff believes that a Class IV Wastewater operator Requirements:

is required.

STAFF RECOMMENDATIONS:

The staff recommends that the Executive Director:

1.

Approve the attached effluent limitations and monitoring requirements.

2.

Direct the staff to reissue VA-NPDES Permit No. VA 0052451.

APPROVED:

// M Executive Dire r

DATE:

///9 5