Westinghouse - Supplement Submittal for Amendment Request Application USA/9297/AF-96 for Model No. Traveller Std, Xl, and Vver Packages
ML20115E573
Person / Time
Site: 07109297
Issue date: 04/24/2020
From: Sloma-Delosier T
Westinghouse, Westinghouse
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
Shared Package
ML20115E572 List:
References
LTR-LCPT-20-09
Download: ML20115E573 (2)


Text

Westinghouse Non-Proprietary Class 3 Westinghouse Electric Company Nuclear Fuel Columbia Fuel Fabrication Facility 5801 Bluff Road Hopkins, South Carolina 29061 USA ATTN: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Direct tel: +1.720.467-5413 Direct fax:

e-mail: Sloma1t@westinghouse.com Your ref: Docket No. 71-9297 Our ref: LTR-LCPT-20-09 April 24, 2020

Subject:

Supplement Submittal for Amendment Request Application USA/9297/AF-96 for Model No.

Traveller STD, XL, and VVER Packages

Reference:

(1) LTR-LCPT-20-06, Amendment Request Application USA/9297/AF-96 for Model No.

Traveller STD, XL, and VVER Packages, Westinghouse Electric Co., LLC, dated April 6, 2020.

Dear Director,

Based on recent communication between myself and Project Manager, Pierre Saverot, Westinghouse is providing reference documents to supplement the Westinghouse amendment request application for the Traveller package license, USA/9297/AF-96 (Reference 1). Supplement documents support the NRC staff review of Safety Analysis Report (SAR) Revision 15, Section 2.12.9, Zirconium Alloy Performance During Testing, and Section 3.2.1.1, Cladding Materials. Three documents, identified in the proprietary enclosure list, are provided to support the analysis inputs of cladding content variations evaluated in the SAR. In conformance with the requirements of 10 CFR Section 2.390, as amended, of the Nuclear Regulatory Commissions regulations, we are enclosing with this submittal an Application for Withholding Proprietary Information from Public Disclosure and an Affidavit, AW-20-5041 (non-proprietary Enclosure 1).

One copy of the supplement application is submitted electronically via NRC Electronic Information Exchange (EIE) system and one is emailed to the Project Manager, Pierre Saverot. Additional electronic or hard copy submissions are available upon request. If you have any questions, or require additional information, please contact me. Thank you for your review time.

Best regards, Tanya Sloma-DeLosier Package Licensing Program Manager Licensing, Compliance, and Package Technology Westinghouse Electric Company LLC

  • Electronically approved records are authenticated in the electronic document management system

Page 2 of 2 Our ref: LTR-LCPT-20-09 April 24, 2020

Enclosures:

Non-Proprietary

Enclosure:

1. LTR-LCPT-20-10/AW-20-5041, Submittal of LTR-LCPT-20-09, Supplement Submittal for Amendment Request Application USA/9297/AF-96 for Model No. Traveller STD, XL, and VVER Packages, dated April 24, 2020.

Proprietary

Enclosures:

1. CN-NFPE-11-91 Rev 1 (entire), Traveller Hypothetical Accident - Fuel Rod Energy Analysis During 9m Drop, Westinghouse Electric Co., LLC, dated April 2020.
2. GATFT-19-058 Rev 0 (Sections 5 and 6), Burst Testing of Chromium Coated Cladding for Accident Tolerant Fuel Final Test Report. Westinghouse Electric Co., LLC, dated October 2019.
3. SMP-TS-2019-028 Rev 01 (Section 3.2.7), Qualification Report for Surface Finished Cold Sprayed Chromium Coated Tubing (Optimized ZIRLO', 0.374 OD x 0.329 ID) for EnCore Program, Westinghouse Electric Co., LLC, dated January 2020.

cc:

T. Grange, Westinghouse-UK W. Stilwell, Westinghouse-USA P. Saverot, US NRC