ML20115D264
| ML20115D264 | |
| Person / Time | |
|---|---|
| Site: | Farley |
| Issue date: | 09/30/1992 |
| From: | Hill R, Woodard J SOUTHERN NUCLEAR OPERATING CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9210200317 | |
| Download: ML20115D264 (9) | |
Text
_
ru nenu m one
,acomny,,
PO'.t Offce Box 1295 E' min 7cm, Alltuma 35201 lelephane PDS 668 b(L66 Ka
}
Southern Nudear Operating Company
- . o. wooo,,,
hNNI$
october 15, 1992 Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Coramission ATTN: Document Control Desk Washington, D. C.
20555 Joseph H. Farley Nuclear Plant Unit I and 2
. Morithlv Operatina Data.Recorts Gentlemen:
Attached are the September 1992 Honthly Operating Reports for Joseph H.
Farley Nuclear Plant Units 1 and 2, as required by Section 6.9.1.10 of the Technical Specifications.
If you have any questions, please advise.
Respectfully submitted,
(-N nds,\\
Jy. Woodard AEJ:edb3014 Attachments cc: Mr. S. D. Ebneter Mr. S. T. Hoffman Mr. G. F. Maxwell l
931o30030 920930
' 93 PDR ADOCK 05000340 Q
R PDR
'g
/
I,l 1
l
\\
l 2
l i
JOSEPH M.
FARLEY NUCLEAR PLANT I
UNIT 1 NARRATIVE SUItMARY OF OPERATIONS September, 1992 i
l The unit was taken off line at 2307 on September 25, for the cycle 11-12 j
refueling outage.
i There were no other unit shutdowns or major power reductions during the-month j
of September.
i The following major safety-related maintenanco was performed during toe month 1.
Miscellaneous corrective and prevcntiv+ maintenance was performed
{
on the diesel generators.
4 2.
Local leak rate tests (LLAT) wero performed on 43 of 118 j
containment penetrations and 21 of 43 eltetrical penetration.
3.
The A, B and C loop main steam safeties i ere tested.
l 4.
Various safety related check _ valves and motor eperated val, a were inspected.
1 I
t 1
i
-l i
i l
5 4
l i
i '
3.
1 i
i ij-
~
1 L
4 i.
l
- 1 I
4
},
2
t OPERATING DATA REPORT i
DOCKET No. 50-348 DATE October 6, llc BONE (b5)BT 56 OPERATING STATUS Notes
- 1. Unit Name:
Joseph M. Farley - Unit 1
- 1) Cumulative data since
- 2. R porting Period:
Seotem0er 1992 12-1-77, date of
- 3. Licensed Thermal Power ( M t):
2,652 commercial operation.
- 4. Nameplate Pt. ting (Gross We):
860
- 5. Design Electrical Rating (Net Me):
829
- 6. Maximum Dependable Capacity (Gross N e):
855.7
- 7. Maximum Dependable capacity (Net m e):
812.0 B. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report,
'~
Give Reasons: N/A
- 9. Power Level To Which Restricted, If Any (Nct Ne):
N/A
~
10.R:asons For Restrictions, If Any:
N/A
'Ihis Month Yr-to-Date cumulative
- 11. Hours In Reporting Period 720.0 6,575.0 130,031.0
- 12. Number Of Hours Reactor Was Critical 599.4 6,45T 4-102,365.3
- 13. Reactor Reserve Shutdown llours 0.0 0.0 3,650.C
- 14. Hours Generatot On-Line 599.1 6,454.1 100,718.4
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0~
- 16. Gross Thermal Energy Generated (WH)
_1,564,342.1 17,035,888.5 258,440,512.6
- 17. Gross Electrical Energy Generated (tMI) 500,420.0
__5,484,566.0 83,269,346.0
- 18. Net Electrical Energy Generated (!MI) 470,288.0 5,201,648.0 78,616,446.0
- 19. Unit Service Factor 93.2 98.2 77.5
- 20. Unit Availability Factor 83.2 98.2 77.5
- 21. Unit Capacity Factor (Using MDC Net) 80.4 97.4 74.7
- 22. Unit Capacity Factor (Using DER Net) 78.8 95.4 72.9
~
- 23. Unit Forced Outage Rate 0.0 0.T 6.7
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
Refueling / Maintenance Outage, September 25; 1992, approximately 54 days.
- 25. If Shut Down At End Of Report Period, Estimated Date of Startup: 11/19/92
- 26. Units In Test M.atus (Prior to Commerciel Operation):
Forecast Achieved INITIAL CRITICALITY 08/06/i7 08/09/77 INITIAL ELECTRICITY 08/20/77 08/10/77-COMMERCIAL OPERATICN 12/01/77 12/01/77 Form 2/34
DOCKET No.
50-348 q
UNIT 1
DATE October 6, 1992 COMPLETED BY R. D. Hill TELEPHONE (205)899-5156 MONTH September DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POVER LEVEL (MVe-Net)
(MVe-Net) 4 1
805 17 702 2
804 18 713 3
801 _
19 806 4
804 20 807 5
804 21 806 6
803 22 804 7
804 23 805 8
805 24 812 9
803 25 667 10 803 26 0
11 804 27 0
12 805 28 0
i 13 805 29 0
i 14 809 30 0
t 15 808 31 16 767 INSTRUCTIONS on this format, list the average daily unit power level in MVe-Net for each day in the reporting month. Compute to the nearest whole megavatt.
t l
l
-^
UNIT SMUTDOWh5 AND POWER REDUCTIONS DCCKET NO.
Jj)-?M UNIT NAME J. M. P ast E Y - L'N ! T 1 DATE October 6. 199?
COM;tETED ST P. O. Mitt REPORT MONTH SEPTEMBER TELEPHONE (205)309-5156 l
l l
l l
lMETHODOF lLICEWSEE l j
l CAUSE 1 C0kRECT!YE l
., l l
l lDURATICW l lSHUTT1kG
} EVENT l SYSTEM lCouPONEgi l
ACTION TC l
5 I
l REPORT # l CODE' l CODE l
PREVENT sECuartkCE l
lDATE l TYPE l(HOURS) l PEASON2lDOWN S
'lNO.
..........................................................'1 ACTOR l002
-l W0925 l
5 l 120.9 l
C l
1 l
N/A l N/A g
N/A lAt 2307, on 9-25-92 the unit a s taken off tine forl l
-l j
-l l
l l
l ltheCycle11-12refuelingcutage.
l l
l l
1 l
I i
i l
i I
I
~l i
I i
l l
I l-I l
i i
i i
i I
i l
i i
l i
i l
I i
l i
i l-1 I
I i
l l
l 1
1 1
I l
'l i
i I
i i
i I
i I
-l I-I i
i i
i l
I i
1 1
i
'l I
I I
i l
I-1 I
I i
I I
I I
I I
i i
i l-I l
I l-1 I
I I
i i
l-1 I
i 1
1 1
I I
i i
i 1
1 I
I I
i i
i l-1 I
i 1
I I
I I
I 1
i-1 I
I I
I:
14 i
i i
i i
i
-l i
I i
.I I
I 1
1 I
I I
i I-1-
I-I I
I I
I I
I I
l I.
1 i
.I I
i i
I it i
l I
l I
I I
I I
I I
I I
i i
i I
'l I
I i
l
.1-1 1
11-1 1
1 1
I l-1 I
I I
I I
'l I
i l
I i
I
.1 l'
l-I l-I I
I I
I: Forced 2
3 Method:
' Exhibit G-Instructions F
Reason:
~ S: Scheduled A-Equipment failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram.
Entry Sheets for Licensee C-Refaling 3-Automatic Scram.
' Event Report (LER) File (NUREG-D-Regulatcry Restrictiert -
4-Other (Explain)
,0161)
E-Operator Training 8.i.icense Examination 5 Exhibit I -Same Source F-Administrative G-Operational Error thpicin)
(9/77).
M-Other (Explain)
1,
-I 4
j j
1 i
i l
JOSEPH M. FARLEY NUCLEAR PLANT i
UNIT 2 3
NARRATIVE
SUMMARY
OF OPERATIONS.
]
September,'1992 4
{
At 0000 on Sept-Jer 19, reactor power was reduced to 15 percent for steam generator. chemical contaminate flushing. The-unit returned to 100 percent i
power on September 21 at 2110.
There were no unit shutdowns during the month September.
4 j
The following major safety related maintenance wrs performed during the months b
I l-1.
Miscellaneous correctiveEand preventive maintenance was performed on the diesel generators-and the B10 sequencer.
'2.
Corrective maintenance was performed on an Agastat-relay in the I
power supply to.the "C" containment. post-LOCA air mixing fan.-
i l
4 i
e i
i
'E
+
}-
I 4
t
.=a
-.a
OPERATING DATA REPORT DOCKET NO. 50-364 DATE October 6, 1992 COMPLETED BY R. D. Hill TELEPHONE (205)899-5156 OPERATING STATUS
- etes
- 1. Unit Name:
Jcseph M. Parley - Unit 2
- 1) Cumulative data since
- 2. Reporting Period:
September 1992 7-30 81, dcte of
- 3. Licensed Thermal Power (M t):
2,652 commercie.1 operation.
- 4. h meplate Rating (Gross We):
860
- 5. Design Electrical Rating (Net W e): 829
- 6. Maximum Dependable Capacity (Gross We):
864.3
- 7. Maximum Dependable Capacity (Net me):
824.0
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: N/A
- 9. Power Level To Which Restricted, If Any (Net MWe):
N/A
~ ~ ' ~
- 10. Reasons For Restrictions, If Any:
N/A
'Ihis Month
'!r-to-Date cumulative
- 11. Hours In Reporting Period 720.0 6,575.0 97,944.0
- 12. Number Of Hours Reactor Was Critical 720.0 4,969.2 82,833.'5
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 138.0
- 14. Hours Generator On-Line 720.0 4,821.0 82,749.5
- 15. Unit Reserve Shutdown Hourb, 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated (&H) 1,779,781.1 11,986,715.7 210,946,037.3
- 17. Gross Electrical Energy Generated (&H) 572,831.0 3,885~,2 3 5. 0 69,181,319.0
- 18. Net Electrical Energy Generated (&H) 543,261.0 3,664.353.0 ~65,598,415.0
- 19. Unit Service Factor 100.0 73.3 84.5
- 20. Unit Availability Factor 100.0 73.3 84.5
- 21. Unit Capacity Factor (Using MDC Net) 91.6 67.6 81__. 7
- 22. Unit Capacity Factor (Using DER Net) 91.0 67.2 80.0
- 23. Unit Forced Outage Rate 0.0 33 4.1
- 24. Shutdowns Schtsduled Over Next 6 Months (Type, Date, and Duration of Each):
N/A
- 25. If Shut DJan At End Of Report Period, Estimated Date of Startup: N/A
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81_
INITIAL ELECTRICITY 05/24/81 05/25/81 CCMMERCIAL OPERATION 08/01/81 07/30/81 Form 2/30
DOCKET NO.
50-364 UNIT 2
DATE 0ctober 6, 1992 COMPLETED BY R. D. Hill TELEPHONE (205)899-5156 MONTH September DAY AVERAGE DAILY POVER LEVEL DAY AVERAGE DAILY POVER LEVEL (MVe-Net)
(MVe-Net) 1 820 17 809 2
819 18 811 3
818 19 201 4
819 20 28 5
818 21
'420 6
815 22 802 7
817 23 804 8
817 24 812 9
817 25 813 10 816 26 813 11 816 27 810 12 816 28
- *)9 13 817 29 811 14 821 30 820 15 818 31 16 811 INStaUCTIONS, On this format, list the average daily unit pcver level in MVe-Net for each day in the renorting month, compute to the nearest whole megawatt.
4
i UNIT SHb7 DOWNS QCD POWER REDUCTIONS DCCKET No.
50-364
~~
L41T NOME
.!. M. F ARLEY
- .Cif 2 DATE october 6. 1992 CCMPLETED SY R. D. MILL REPORT MONTH SEDTEMBE R TELEPHONE (2051899-5156 l
l l
l l
lMETHODOf l LICENSEE l l
l CAUSE 1 CORRECTIVE l
l l
'l l DURATION l
,l SHUTTING l EVENT
[ SYSTEM l COMPONENT l
ACil04 TO l
I l REPORT # l CODE' l CODE l
PREVENT RECURRENCE l
S l WO.-
lDATE l TYPE l (HCL *RS) lREA$0N2 l DOWN REACTOR 3
.l012 l920919 l
S l69.2 l
B l
N/A l
- fA lN/A
)
SG lAt 0000 on 9-19 M, reactor power was reduced to (
l l
l l
l l
l
[
]
l15%forsteamgeneratorchemicalcontaminate l
l 1
1 1
1 1
I I
I Iftushir*.
I I
I I
I I
I I
I I
i 1
1 I
I
'l i
I I
I I
I f
I I
i l
i 1
i l
I I
i 1.
I I
I I
I I
I I
I I
I I
i 1
1 I
I I
I I
I I
i i
i I
I I
I I
I I
I I
I I
I I
I I
I i
1 1
I I
i i
i I
I I
I
.I I
I I
I I
i i
i l
i l
i 1
I I
I I
I I
I I
I I
I i
1.
I I
I I
i 1.
I l-
.l.
I I
I I
I I
1 l
l 1
I
.I I
I I
I I
I i
I I
I i
i I
i i
i l
I l
I i
l i
l i
i i
i i
1
'l 1
1 I
I I
I I
I I
I l
i I
I I
I I
I I
I I
I I
i i
i i
l I
i i
1 l-1 I
I I
I I
I I
I I
I I
I I
I I
i I
i i
i I
i i
l I
l-
-l i
I I
I I
I I
I i
'l i
I I
I i
7: Forced 2
hethod:
'Eshibit G-Instructions F
Reason:
5:-Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data S-Maintenance or Test 2-Mantal Scrara.
Entry Sheets for Licensee C-Refueling 3-Automatic Scrara.
Event Report (LER) File (NUREG-D-Regulatory Restriction' 4-Other (Explain) 0161)
E-Operator Training & License Examination SExhibit I -Same Source F-Acteinistrative G-operational Error (Explain) u
~_
,