NPDES Discharge Monitoring Rept for Sept 1992
ML20115B439
Person / Time
Site: Perry 
Issue date: 09/30/1992
From: Grimm J, Lyster M
CENTERIOR ENERGY
To:
OHIO, STATE OF
References
PY-CEI-OEPA-016, PY-CEI-OEPA-16, NUDOCS 9210160063
Download: ML20115B439 (5)


Text

.

'C.ENTERIOR ENERGY PERRY NUCLEAR POWER PLANT Mail Address.

P O. DOX 97 Michael D. Lyster 10 CENTER, Ngo PERRY, OHIO 44081 g pggg, g, PERRY, C 410 4 091 (216) 259 " 37 October 13, 1992 PY-CEI/0 EPA-0163 L Ohio EPA Division of Vater Pollution Control Enforcement Section, ES/MOR 1800 Vatermark Drive Columbus, Ohio 43266-0149 Gentlemen, Enclosed are the NPDES monthly report forms for the month of September, 1992.

Please feel free to call if you have any questions.

Sin et ly, M

Michael D. Lyster MDL:LKB:ss Eaclosure cc: NRC Project Manager NRC Resident Inspector Office NRC Document Control Desk NRC Region III 15003.

9210160063 920930 PDR ADOCK 05000440 A

1 R

PDR f,). h ove-: g c: va

~. _,

5 da Fa s <

4500

.)NTHLY REPORT FORM CLEVELAND ELECTRIC ILLUM CO 3IB00016004 SEP 1992 1 1 GHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 004 POINT REP OF DISCHARGE PRIOR 7 NORTH PERRY 44081 LAKE ENTRY TO TUNNEL Fonu 4

CEI, PERRY J.J. GRIMM 1

1 3

3

.999 999-1 1

WATER CONDUI CHLOR PH TEMP FLOW FREE A F.

MGD MG/L S.U.

2__._00011.

50050

.50064,_00400 01.

74 92.2 0.00 8.2 Ca. _ _

76 91.9 0.00 03 76 100.4 0.00 j

04 75 103.2 0.00 8.1 05 75 93.7 0.00 1

06 76 88.0 0.00 07 75 93.7 0.00 08 76 89.0 0.00 8.3 09 75 95.2 0.00 to 75 95.9 0.00 11 71 102.7 0.00 8.2 12 71 107.2 0.00 13 71 108.2 0.00 14 72 103.5 0.00 15 75 94.7 0.00 7.9 16 75 93.0 0.00 17 76 90.7 0.00 to 77 84.8 0.00 8.2 to 75 88.7 0,00 20 74 83.1 0.00 21 76 98.4 0.00 i 22 75 94.4 0.00 8.2

! 23 72 97.1 0.00 l24 70 95.9 0.00 25 70 100.6- 0.00 8.1 26 71 91.7 0.00

! 27 71 101.1 0.00 l28 71 92.3 0.00 8.5

', 29 69 101.5 0.00 ao 67 118.6 10.00 j 31 2202 2891.4 0.00 73.7 i

73 96.4 0.00-8.2 77 118.6 0.00 8.5 07 83.1 0,00 7.9 i

i

{

NONE l

mpomun e.

r 4.

1

~

'^

e 4500 MTHl.Y REPORT FORM CLEVELAtid ELECTRIC ILLUM CO 31B000)6002 SEP. 1992 11 OHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 002 DISCHARGE FROM CHEMICAL CLEANING NORTH PERRY 44081 LAKE _

LAGOON E PLANT ronu 1

CEI. PERRY J.J. GRIMM-1 1

2 3

2 2

2 999 999 96 1

96 96 96 C0!!DUI PH RESIDUE O&G PHOS-T COPPER IRON FLOW T NFLT TOTAL P-WET CU, TOT -FE, TOT MGD S.U.

MG/L MG/L MG/L

.MG/L UG/L 50050 00400 00530 00550 00665 01042 01045 01 02 03 -

04 05 06 07 OB 09 10 11 12 13 14 15 16._ __

17 la 19 -

20 '

21 t

' 22 23 24 25 26 27 29

' 29 30 M

UO; DISCHARGE OCCURRED DURI!!G THE MONTH w roarra

,....J..

...m..

.,... ~.,

4500

)THLY REPOM FOHfA, CLEVELAND

  • ELECTRIC ILLUM CO 3IB00016001 SEP 1992 1 1 OH10 NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 001 DISCHARGE FROM REGENERATE 1

NORTH PERRY 44081 LAKE NEUTRALIZATION PITS ronu rEI, PERRY J.J. GRIMM' 1

1 1

2 3

999 999 999 96 1

i CONDUI PH PH RESIDUE O&G FLOW (MAX)

(MIN)

T NFLT TOTAL MGD S.U.

S.U.

MG/L MG/L 50050 00401 00402 00530 00550 1

AH AH AH 2

AH AH AH 3-AH AH AH 4

AH AH All 5

AH AH l'8 s

AH AH A.,

or AH AP AH pa AH AH AH 09 AH AH AH 10 0.0332 7.6 7.3 28 AA it AH AH AH s

l12 AH AH AH

t. 3 AH AH AH l14 AH AH AH l15 AH AH AH
is -

.AH AH AH

i7 AH AH AH l1s 0.0130 8.9 6.6 l19 AH AH

-AH 20 AH AH AH i21 AH AH-AH l22

'O.0160 8.2 7.- 8 9

AA (23 AH AH AH

!24 -

AH AH AH

25 AH AH AH l2s -

AH AH-AH

[27 AH AH AH l2s 0.0142 8.3 8.1-5 AA

[29_

.AH AH AH jao AH AH

-AH

!ai O.0764-33.0 29.8 42 AA 0.0191 G.3 7,5 14' AA 9.0132 8.9.

0.1 ~

-28 AA 0.-0130

-7.6 6.6 5-AA AA.- BELOW DETECTABLE. LIMIT f5 mg/l for O&G and 2.5 mg/l for RESIDUE)

AH - SAMPLE NOT TAKEN. NO DISCHARGE PERFORMED THIS:DATE 4tPORTEM

..,_.,.<-,,4...-,.....<,_....
    • $ 'w &

t

'HLY Rt PCHf FOHM CLFNELAND ELECTRIC ILLUM CO 3IE00016800 SEP 1992 1 1 OHIO NU ". EAR GROUP 63461 Cc PE2RY NUCLEAR POWI". PLANT 10 CENTER ROAD RC0" E210 800 INTAKE WATER AT INLET TO PLANT UORTH PERRY 440e' LAKE FP.0M LAKE ERIE rosv Ci &, PERRY J.J. GRIhD1 1

}

999 m.

4 u

3 68 t

1 A

..t 69

~

69 t

69

'h 69

.a 7v 9

69 4

o 69 a

1 69 2

68 3

(40

'4 68 5

68 6

69

'7 69 a

70

'9 69

o 08

't 60

2 68 67

?a 64

!s 64

's 64 a

64

.l d h-a

's 63

o 61 4

31 202" 67 70 61 NOME PEPOR TER

[g*

J.J 'O wmy

,;,.