I

~

f Departen:nt cf Nucl:Cr Cng!neering Conogo of Engineonng Nuclear Engineene g Tex %s A&M unteersity Safety Enguienn ;

College Station.TX 77843-31*D 1

industnal Hygieri e 409/845-4161

  • Fax 409/845 6443 7

Hearth Physic,

28 Aug1992 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555

REFERENCE:

License R-23, Docket #50 59

Dear Sir:

Please find enclosed one copy of the most recently completed annual operating report dated 1 June 1991 to 31 May 1992 for the AGN-201M reactor, Docket #50-59, if you have any questions concerning this report please contact me at (409) 845-498-Sincerely,

/

{ D. '

i Robert O. Berry Reactor Supervisor AGN-201M s

i I 00Ya l

r,

[k 92o9000152 920531

/ V i

PDR ADOCK c50000S9

,/

k R-

PDF, j

u a

.a

+

1

- k

+-

.~

y t

ANNUAL O'PERATING REPORT of the Q~

TEXAS A&M UNIVERSITY'AGN 201M TRAINING REACTOR

' NRC LICENSE R-23 JUNE 1,1991 - MAY 31,1992 A

w DEPARTMENT OF NUCLEAR ENGINEERING TEXAS A&M UNIVERSITY College Station, Texas 77743-3133-I I

i r m a

ec

p y

-4 ANNUAL OPERATING REPORT of the TEXAS A&M UNIVERSITY AGN-201M TRAINING REACTOR NRC LICENSE R 23 JUNE -1,1991 - MAY 31,1992 j

.g Reviewed by RedclorAupervisor

(

% $O / hL:_

)diewed'b'y Department Head R;

w DEPARTMENT OF NUCLEAR ENGINEERING TEXAS A&M UNIVERSITY College Station, Texas 77743.-3133 l

l~

l-

t

1. SUMM ARY This report details the pertinent activities related to the Texas AG,A University. AGN-201M training facility operated by the Department of Nuclear Engineering during the periori of 1 June 1991 until 31 May 1992.

The contents of this report are intended to comply with requirements of-10CFR50 section 50.59(b), and Appendix A of the Technical Specifications for this facility under. license R-23.

The main functior, of this facility is to provide 71 operating nuclear s'ystem to be used as a research tool, to support the requirements of Nuclear Engineering courses and for operator training as well as

- preventive maintenance. The following Nuclear Engineering courses were supported during this reporting penod:

NUEN 405:. Nuclear Engineering Experiments NUEN 679:

Practical Applications of Radiological Safety 1 i

All of the components that were replaced as part -of preventive and corrective. maintenance are detailed in Section 4 of this report. All of-the

- components replaced during this reporting period do not involve any

~

unreviewed safety ' questions and are not expected' to adversely affect the safe operation of this facility.

During this reporting period both Channel 1 7

and 2 failed, 'ho failuta c' these components and the subcequent time to repair each drawer resulted in the fact that none of the major preventive maintenance was performed during this reporting period.

All requirements 1

of tne technical specifications were meet and the required maintenance were performed within the time limits and all resuits were within normal paramotorr of operation.

b

~

2.. OPERATIONAL

SUMMARY

UTILIZATIOR BY CATEGORY 110]B$

s (a) Support of Nuclear Engineering Ocurses 12.8 (b) Operator Training /Requalification 9.73 (c)

Preventive / Corrective Maintenance 0.72 s

o Total Ooeratina Hour,

23.25 Tof al H.oltLs._GIitical 12.43 l

101aLWaMio.uls__0LOREatiom 3.23 Averace Power Level of Ooeral!on (Wah 00.98 Number of ReactoLSladu.02 36 4

.______-___-___-________-__________N

~

3. UNSCHEDULED SHUTDOWNS DfdE IYPE D.AUSE CORREQllVE ACT103 92691 High '.evel Operator error in Trainee counseled Channel #3 in switching scales l

9 PG 91 High Level Meter spike when Switch rotated to Channel #3 switching scales

- clean all contacts 1 10-92 High Lovel Operator error in Trainee counseled Channel #3 in switching scales i

1

4. MAJOR SAFETY RELATED CORRECTIVE MAINTENANCE j

- (a) 10/17/91 Replaced the following tubes in Channel #2 with l

identical replacements: V-12, V-6, V 10 and V 15.

o b

(b) 10/18/91 Replaced the following tubes in Cnannel #2 with l.

identical replacements: V-12, V G. V-16 and V 15.

(c) 12/1/91 Replaced and repaired several connections and resistors

' i and capacitors in 125 voit power circuit to Channel #2 l

l with equivalent or newer components.

)

(d) 6/29/92 Repleced 24 volt power supply in Channe! #1 with an equivalent power supply.

5.-

(a) FACILITY CHANGES A new metal door with digital and spring return locks was added to

- the. facility at F-1.

This _ new door is intended to replace the hydraulically operated concrete _ door currently in use at this location.

.While-the ~ old door remains in place it is no longer used to control access-into the Accelerator Room.

i p

,w a.

e

+r

, -..r-

+-

n=

~

3 m---e-m

- + - -

v e

ev - -


=-----------'s------'e---

(b) chi,NGES TO PLANS AND PROCEDURES The Secunty P!an and the facility floor plans have been updated to reflect the newly installec dual lock door at located F-1.

(c) NEW EXPERIMENTS OR TESTS No new experirnents or tests were performed during this reporting period.

G.

SUMMARY

OF SAFETY EVALUATIONS No changes, tests or f..<poriments were performed during this reporting period which meet the criteria of 10CFR50 paragrapa 50.59 requiring a safety evaluation.

7.

SUMMARY

OF RADIOACTIVE EFFLUENTS RELEASED No liquid or solid radioactive waste was released during this reporting perind.

-9.

ENVIRONMENTAL RADIOLOGICAL SURVEYS No environmental radiological surveys were performed outside this facility during this reporting period.

9.

RADIAT!ON EXPOSURE During calender year 1991 twa people had exposures that were reported between 0.250 - 0.500 rem. All of-the other exposures were 4

- reported to be less than 0.100 rem.

f L

l M.

p.-,:a m

.,c.

,.m..,y.

.,,,,y.

,3_,_,---.-..9.--y g

y 9y wg...%wn,

.~. _ _ _. _. _._.-._._._._..____ _ _____ _ _ _ _ _.._ _ ___,

e i

l l

10. MISCELLANEOUS i

The followinn personnel currently hold activ6 licensos for the AGt-620lb1

)

i Robert Berry SOP - 43374

~ John Court OP - 70038 lan Hamilton

- OP - 70023 During this reporting period both John Court and Ian Hamilton received their operating licenses.

i f

p t

5 J

.<v

.... ~....,,, - -,