Corrected Tech Spec Page 3/4 7-21,section 4.7.8.b,for Amend 160 to License DPR-65
ML20114C006
Person / Time
Site: Millstone 
(DPR-65-A-160)
Issue date: 08/26/1992
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20114C008 List:
References
TAC-M82750, NUDOCS 9209010075
Download: ML20114C006 (2)


Text

- - -

1 4,

P' PLANT Sf111MS-1 3/4.7.8 SNUBiti,R.S 4f

,i llMITING CONDITION FOR OPERATION All snubbers shall be OPEPABLE. The only snubbers excluded from the 3.7.3 requirements are those installed on nonsafety-related systems and then only if 1

their failure or failure of the system on which they are installed would have i

no adverse effect on any safety-related system.

APPLICABILJ.H: MODES 1, 2, 3, r.nd 4.

MODES 5 and 6 for snubbers located on 4

j systems required OPERABLE in those MODES.

~

l ACIlON:

1 With one or more snubbers inoperable within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> replace or restore the inoperable snubber (s) to OPERABLE status and perform an engineering enluation i

per Specification 4.7.8.d on the attached component or declare-the attached l

f.

l system inoperable and follow the appropriate ACTION statement for the systen 4

7V,EILLANCE.RE0VIREMLNTS i

t

4. ).8 Each snubber shall be demonstrated OPERABLE by performance of the following augmented inservice inspection program and the requit uments of Specification 4.0.5.

o a.

Inspection TYDes l

As used in this specification, " type of snubber" shall mean snubbers i

of the same design and manufacturer, irrespective of capacity.

b.

Visual Inspections Snubbers are categorized as inaccessible or accessible during -

reactor operation.

Each of these. categories (inaccessible and..

accessible) may be inspected independently according to the schedule 1'

determined by Table 4.7-3.

The visi'ai inspection interval for each type of snubber shall be determinea based upon the criteria provided i-in Table 4.'i-3 and the-first inspection interval determined using-this criteria shall be based upon the' previous inspection interval as established by the requirements in effect leefore Amendment 160.

c.

Visual InsDection Acceptance Criteria Visual inspections shall verify that (1) the snubber I.as no visible-indications of damage or impaired OPERABILITY, (2) attachments to the foundation or supporting structure are functional, ar.d (3) fasteners for the attachment of the snubber-to the component and to-l the snubber anchorage are functional. Snubbers.which appear inoperable as -a result of visual inspections shall be classified-as unacceptable and may_ be reclassified acceptable for the purpose:of

~

establishing the next visual. inspection. interval, provided that-(1) the cause~ of the rejection is clearly established and remedied for-~

that particular snubber and for other snubbers irrespective of-type Millstone-Unit 2 3/4 7-21 Amendment'No. JJ, fJ, #,

N III' Corrected by lett'er dated -

L 9209010075 9P0826 PDR -ADOCK 05000336; 8/26/92.