Text
_.
. /p e
- t s y'c.
UNITED STATES
'~j NUCLE AR REGULATORY COMMISSION y
y.
e W ASHING'oN. O. C. 2055$
t
/
% m.. p DETROIT EDISO4 COMPANY FERMI-2 DOCKET NO. 50-341 M DMENT TO FACILITY OPERATING LICENSE Amendment No. 84 License No. NPF-43 1.
The Nuclear Regulatory Comissi-(the' Comission) has found that:
A.
The application for amendment by the Datroit Edison Company (the licensee) dated January 28, 1992, complies with tne standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the ccmmon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in'accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes 13 the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Ope ating License No. NPF-43 is hereoy amended to read as follows:
Technical Specifications and Environnental Protection Plan The Technica~1 Specifications contained in Appendix A, as revised through Amendment No. 84, and the Environmentti Protecticn Plan contained in Appendix B,-are hereby incorporated in the license.
Deco shall operate th; i:.cility in accordance with the Technical Specifications and the environmental Protection Plan.
9208310307 920825 PDR ADOCK 0500034A P
PDR'
' 3.
This license amendment it. effective as of the date of its issuance with full implementation within 45 days.
FOR THE NUCLEAR REGULATORY COMMISSION Ledyard B. Marsh, Director Project Directorate 111-1 Division of Reactor Projects lil/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of 'ssuance:
August 25, 1992 l
l
PLANT SYSTEMS 3/4.7.5 SNUBBERS LIMITING CONDITION FOR OPERATION 3.7.5 All* hydraulic and mechanical snubbers shall be OPERABLE.
i APPLICABILITY:
OPERATIONAL CONDITIONS 1, 2, and 3.
OPERATIONAL CONDITIONS 4 and 5 for snubbers located on systems required GPERABLE in those OPERATIONAL CONDITIONS.
j l
ACTION:
With one or more snubbers inoperable on any system, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> replace or restore the inoperable snubber (s) to OPERABLE status and perform an engineering evaluatien per Specification 4.7l.5g on the attached component or declare the attached system inoperable and follow the appropriate ACTION statement fer that system.
SU:vElttL'CE DEOU1REMENTS 4.7.5 Each snubber shall be demonstrated OPERABLE by performance of the fol b ing augmented inservice inspection program in addition to the re;;irements of Specification 4.0.5.
I a.
Jespection TyDes l
As used in this specification, type of snubber snall mean snubbers l
of the same design and manufacturer, irrespective of capacity.
b.
Visual Inspections Snubbers are categorized as inaccessible nr accessible during reactor operation.
Each of these categories (inaccessible and I
accessible) Uy be inspected indepeMently according to the I
schedule determined by Table 4.7.51.
The visual inspection I
interval for each category of snubber shall be determined based I
upon the criteria provided in Thble 4.7.5-1.
The first inspection I
interval determined using this criteria shall be based upon the I
previous inspection interval as established by the requirements in I
effect before Amendment 84.
'As described in the bases.
l l
l FERMI - UNIT 2 3/4 7-16 Amendment No. 84
--