Text

_

e.

~

GE NucIcar Energy o

... f a,

o t

4 April 14,1992 MFN No. 088-92 Docket No.STN 52 001 SLK 9253 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention:

Robert C. Pierson, Director Standardization and Non Power Reactor Project Direct nate

Subject:

GE Responses to the Resolution ol' Selected Issues Related to ABWR DSER Chapter 19 (SECY 91309)

Reference:

Submittal of Amendment 4 to GE's ABWR SSAR, MFN NO. 05 89,

~

dated January 31,1989 Submittal of Amendment 8 to GE's ADWR SSAR, MFN NO. 052 89, dated July 28,1989 Enclosed are thirty-four (34) copies of the GE responses to SECY-91309 Outstanding Items 1 and 6.

Please note that this material contains information that is designed as General Electric Company proprietary information. This material relates to the Chapter proprietary information that was previously sent to the NRC via the above referenced letter and their corresponding proprietary affidavits.

It is intended that GE will amend the SSAR with these responses in a future amendment.

Sincerely, R.c.w u dLL R. C. Mitchell, Acting Manager Regulatory and Analysis Services M/C 444, (408) 925-6948 cc: F. A. Ross (DOE) g N. D. Fletcher (DOE)

G. B. Kelly (NRC) gge[0(

l O C. Poslusny, Jr.

(NRC)

R. C. Berglund (GE)

J. F. Ouirk (GE)

]

Y.s

- i 9 9204160229 920414 PDR ADOCK 05200001 A

PDR

__