ML20113F427

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Nov 1984
ML20113F427
Person / Time
Site: Summer 
Issue date: 11/30/1984
From: Dixon O, Loignon G
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Barry L
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8501240015
Download: ML20113F427 (5)


Text

-

n Director,-Office of Resource ~ Management November Monthly Operating Report December 12, 1984-ATTACHMENT I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50/395 UNIT V.

C.

SUMMER I DATE 12/12/84 COMPLETED BY G.

A.

Loignon TELEPHONE (803) 345-5209 MONTH NOVEMBER 1984-DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net).

(MWe-Ne t ) -

1.

-7 17.

-8 2.

-6 18.

-8 3.

-7 19.

-8 4.

-8 20.

-14 5.

-8 21.

-14 6.

-7 22.

-14 7.

-7 23.

-14 8.

-8 24.

-14 9.

-7 25.

-14 10.

-7 26.

-14 11.

-7 27.

-12 12.

-7 28.

-10 13.

-8 29.

-14 14.

-8 30.

-14 15.

-7 31.

N/A 16.

-7 i

8501240015 841130

~f k b" I PDR ADOCK 05000395 R

PDR n

l

8 L

Director, Office of Resource Managenent.

i November 2nthly Operating Report Page 2 nanamhar 12, 1984 ATBCHMENT II 0?J! RATING DATFL REPORT DOCKET NO.

50/395 UNIT V. C. SUMER I DATE 12/12/84 000fLETED Bf G. A. Ioignon TELEPHONE (803) 345-5209 t

l

~ OPERATING STA'IUS

1. Reporting Period:

NOVBBER 1984 Gross Hours in Reporting Period: 720

2. Currently Authorized Power Invels(MWt):

2775 Max. napand. Capacity (Mee-Net):

885 Design Electrial Rating (MWe-Net):

900

3. Power Ievel to which restricted (If Any)(MNe-Net): N/A i
4. Reasons for Restrictions (If Any):

N/A'-

i

'IHIS KNIH YR 'IO DATE CWUIATIVE i

5. Nunber of Hours Reactor itas Critical 0

5,253.5 5,253.5 i

6. Reactor Reserve Shutdom Hours 0

0 0

7. Hours Generator on Line 0

5,095.6 5,095.6 l

8. Unit Reserve Shutdom Hours 0

0 0

9. Gross 'Ihermal Ehergy Generated 0961) 0 12,876,704 12,876,704
10. Gross Electrical Ehergy Generated (Miti) 0 4,286,339 4,286,339
11. Net Electrical Ehergy Generated (Mei)

-6,920 4,067,389 4,067,389

12. Reactor Service Factor 0

65.3 65.3

13. Reactor Availability Factor 0

65.3 65.3

14. Unit Service Factor 0

63.4-63.4

15. Unit Availability Factor 0

63.4 63.4

16. Unit Capacity Factor (Using EC) 0 57.2 57.2
17. Unit Capacity Factor (Using Design MNe) 0 56.2 56.2
18. Unit Forced Outage Rate-0 11.2 11.2.
19. Shutdowns Scheduled Over Next 6 2nths (Type, Date, and Duration of Ehch):

N/A

20. If Shut Down at Ehd of Report Period, Estimated Date of Startup: 12/14/84
21. Units in Test Status (Prior to Caseerical Operation):

PGUK:AST ACHIEVED.

Initial Criticality N/A 10-22-82 Initial Electricity N/A 11-16-82 i-Oasearcial Operation N/A 01-01-84 l

P s

Director, Of fice of Resource Management November Monthly Operating Report Page 3 D:cember 12, 1984 ATTACHMENT III UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

50/395 UNIT V.

C.

SUMMER I DATE 12/12/84 COMPLETED BY G.

A.

Loignon TELEPHONE (803) 345-5209 (1)

METHOD OF (2)

TYPE SHUTTING DOWN F: FORCED DURATION-THE REACTOR OR CORRECTIVE ACTIONS /

NO.

DATE S: SCHEDULED (HOURS)

REASON REDUCING POWER COMMENTS 11 840928 S

720.0 C

4

11) Refueling Outage

s Director, Officelof Resource Management November Monthly Operating Report Page 4 December 12, 1984 ATTACHMENT IV NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE The Virgil C.

Summer Nuclear Station, Unit No.1, was shut down for refueling during the month of November 1984.

On November 11,1984, at 0855 -heurs, the offload of fuel from L.ie reactor vessel commenced.

Offload was completed at 1220 hours0.0141 days <br />0.339 hours <br />0.00202 weeks <br />4.6421e-4 months <br /> on November 14, 1984.

On November 17, 1984, core reload was begun.

Reload was complete at 1939 hours0.0224 days <br />0.539 hours <br />0.00321 weeks <br />7.377895e-4 months <br /> on November 19, 1984.

On November 30, 1984,- the Plant was in Mode 5 preparing for startup.

i l

p:

N

.gX SOUTH CAROLINA ELECTRIC & GAS COMPANY -

Post OFFICZ 764 COLuusiA south CAROLINA 29218 O. W. DIMON, JR.

Vice PassiosNT -

suct a. o

.ario~.

December 12, 1984 Director, Office of_ Resource Management U.S. Nuclear Regulatory Commission MNBB 7602 Washington, DC 20555 ATTN:

Mr. Learned W. Barry

SUBJECT:

Virgil C.

Summer Nuclear Station Docket No. 50/395.

Operating License No. NPF-12 November Monthly Operating Report

Dear Mr. Barry:

Please find enclosed the November 1984 Monthly Operating Report for the Virgil'C. Summer Nuclear Station Unit No. 1.

This submittal is made in accordance with the requirements of

. Technical Specification 6.9.1.10.

If there are any questions, please call us at your convenience.

Very tr yours s

O. W.

Dx CJM: GAL:OWD/lcd Attachment cca V. C.

Summer

.C.

L. Ligon (NSRC)

T. C. Nichols Jr./O. W. Dixon, Jr.

K.

E. Nodland E.

H. Crews, Jr R. A.

Stough E. C. Roberts G. Percival W.. A. Williams, Jr.

C. W. Hehl H.

R. Denton J. B. Knotts, Jr.

J. P.

O' Reilly INPO Records Center Group Managers ANI Library.

D. A. Nauman L.

N.

Carter O. S. Bradham C.

S.-Gramling C. A. Price NPCF-FILE.

'///

T64

-