Part 21 Re Matl Supplied by Bonney Forge Lacking Chemical Overcheck.Encl Notification Ltr Sent to Recipients of Matl Lacking Chemical Overcheck.Exhibits Used in Conjuction W/Ltrs Also Encl
ML20113D461
Person / Time
Site: Fermi 
Issue date: 05/25/1984
From: Grunthaler
GUYON ALLOYS, INC.
To: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-84 NUDOCS 8504150307
Download: ML20113D461 (36)


Text

f GuiUN ALLOYS,IE s

TUBULAR PRODUCTS FOR THE ENERGY INDUSTRIES 1

m 950 South Fourth Street, Harrison, N.J. 07029 (201) 485-5050 Y2. )

United States Nuclear Regulatory Cmmission Washington, D.C. 20555 Attn: Mr. Edward L. Jordan, Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement

Subject:

Bonney Forge Material lacking Cbmien1 Overcheck Requirement of ASME Section III Paragraph NCA-3867.4(e)(2).

In accordance with the request contained in your letter of March 16, 1984, attached please find a copy of our notification letter typical of the notification sent to all recipients fra Guyon Alloys of material identified by Bonney Forge as lacking the ref-crenced ch=4 cal overcheck, together with a copy of our letter to Bonney Forge referred to in our notification letter, dich advises of a neber of missions or errors in the Bonney Forge notification and requests more detailed infonnation for assistance of the material recipient or licensee's deviation evaluation.

Also attached is one copy each of 26 of our Ddtibits I used in conjunction with our notification letters to identify the material in question furnished to each purchaser, In addition to identifying the purchaser, purchaser's order number, and material identity, except for one unidentified overseas project, the exhibits indicate the licensee and the licerisee's nuclear plant site for which the material was procured, With the excepticn of unshipped porticris of SA-1051/4" 6000# 'Ihreaded Caps of Heat Code 497T, 3/8" 3000# SW Half Couplings of Heat Code BN66, 3/8" 6000# SW Couplings and and Half Couplings of Heat Code BR57, three 16"x16" Std. Wt. Weldolets of Heat Code 210 one 18"x16" Std. Wt. Weldolet of Heat Code 437K remaining and quarantined in our Harr N.J. and Houston, Texas warehouse inventories, the 26 Exhibits I account for all it ms of material and quantities thereof shown on our corrected order / material listing sent and attached to our letter to Bonney Forge. 'Ihe quarantined inventory itms will be sold only for cmmercial quality applications or will be eventually returned to Bonney Forge, If any additional information is required or desired, the undersigned may be contacted at our letterhead address or telephone number.

i b

Very truly ours, eg04%h 4%/&~yf/w - [?

AI M e

V

% ;p" ge E. Grunthaler Vice President v

&[

Technical Services J

0 e

O ElYON ALLOYS,IE g

TUBULAR PRODUCTS FOR THE ENERGY INDUSTRIES 4

950 South Fourth Street, Harrison, N.J. 07029

- T (201) 485 5050 May 24, 1984 Reactor Controls, Inc.

5854 Butternut Drive East Syracuse, NY 13057 Attn:

Mr. Tony Iosue

Subject:

RCI Orders J103-477, J103-489, & J103-491 Enrico Fermi Nuclear Station-Unit No. 2 10CFR21 Notification Pursuant to the notification requirements of the Code of Federal Regulations Title 10, Part 21 (10CFR21) and confirming previous advice, par attached copy Guyon Alloys has received a notification from the Bonney Forge-Gulf & Western Manufacturing Company advising that some meterial shipped from their Carlinville, Illinois plant has been fur-nished to Guyon Alloys with incomplete documentation and lacking the chemical overcheck requirement of Para. NCA-3867.4(e)(2),

Based on a thorough review of our records in conjunction with the material listing received with the Bonney Forge notification, some of tha items of material cited by Bonney Forge have been identified as hsving been in turn furnished by Guyon Alloys against the subject order (s) for the referenced groject.

The items so identified are listed on attached " Exhibit I As discussed in the attached copy of our return letter to Bonney Forge, it is suspected that the identified items have been manufactured from unaualified stock material which was incompletely or improperly qualifidd (upgraded) under the provisions of NCA-3867,4(e) or NA-3767,4(e) es and if applicable.

Additional detailed information as requested by our letter will be relayed to you upon receipt from Bonney Forge, In as much as Guyon Alloys as a material supplier does not have the cepability of determining whether the use of the discussed material as furnished may create a substantial safety hazard, this notification and tha additional information to follow is being provided to facilitate your such determination.

6 e

e GUYUli ALLOYS,IE g

TUBULAR PRODUCTS FOR THE ENERGY INDUSmlES J

3""!

~

950 South Fourth Street, Harrison, N.J. 07029 (201) 485-50'A Please note that under the size / quality program exclusion provi-sions of Paragraph N(x)-2610 per the 1974 Edition / Winter 1975 Addenda and later Edition and/or Addenda of ASME Section III, it may be pos-sible.to consider 2" nominal pipe size or smaller fittings as liste.d on Exhibit I acceptable as furnished.

For such fittings procured to en earlier Code Edition and/or Addenda, the use and acceptance.of the size / quality program exclusion provisions per a later Code Edition and Addenda may be necessary.

Please advise Guyon Alloys of the results of your determination of whether the use of the fittings as furnished would create a sub-senat.ial safety hazard, the ' status, and any proposed disposition of the fittings involved.

Very truly yours, G

ON S

yC.

Li w

, -d 1 l o

George H. Grunthaler Vice President Technical Services t------------------

-.2

r.....

I G,UY@N ALL.GYS', INC.

EXHIBIT I

Orders No. J103-477, J103-489, & J103-491 Purchaser: Reactor Controls, Inc.

Proj ect:

Enrico Fermi Nuclear Station - Uni.t No. 2 Detroit Edison Company Order J103-477 SA-234 Grade WPB, ASME Section III Class 2, 1977 Edition / Summer 1978 Addenda Item #1.

3 pes. 10"x8" XH Weldolets, Bonney Forge Heat Code 342DD Date shipped:

5/2/80 (G/A A-31273-N)

_ Order J103-489 SA-234. Grade WPB, ASME Section III Class 2, 1977 Edition / Summer 1977 Addenda Item #4..1pe. 12"x8" XH Weldolet, Bonney Forge Heat Code 342DD Date shipped:

5/13/80 (G/A A-31305-N)

Order J103-491 SA-105, ASME Section III Class 2, 1977 Edition / Summer 1978 Addenda Item #3.

1pe, 10"x8" XH Weldolet, Bonney Forge Heat Code 345DD Date shipped:

9/25/80 (G/A A-31377-N)

L.

s m s A u s a m c.

TUBULAR PRODUCTS FOR THE ENERGY INDUSTRIES

(~

950 South Fourth Street, Harrison, N.J. 07029

- r (201) 48 5 5050 May 7, 1984 G & W Bonney Forge Gulf & Western Manufacturing Company 201 West Mount Street Carlinville, Illinois 62626 7

Attn:

Mr. D.L. Kale 0.uality Control Manager

( 35 CC:

Mr. P.R. Benavides Quality Assurance Manager G & W Bonney Forge P.O. Box 359 Cedar & Meadow Streets Allentown, Penna.

18105

[ 89 0

Subject:

Your letter notification dated 2/15/84 of material furnished without,the " chemical overcheck" requirement of Para. NCA-3867.4(e)(2)

Receipt of your subject notification letter and the three page listing of order numbers, item numbers, heat numbers (codes) and fitting descriptions attached thereto is herewith acknowledged.

Your referred to listing is disorganized, includes apparent errors or omissions, and in many cases references item numbers of your mill orders which do not relate to item numbers of Guyon Alloys purchase orders.

There-fore it has been necessary to perform a very time consuming review and search of our records to properly identify items involved with probable non-conformity and to accordingly identify recipients of probable nonconforming Bonney Forge material.

All documentation which had been provided by you for listed items included certification of ASME Section III conformance, manufacture under an NA-3700 or NCA-3800 Quality Program, and for items purchased after March 1979 supply under your ASME Qualified Program with one set of chemical proper-ties and one set of physical properties reported for each item.

Such docu-montation did indicate and was accepted on the basis that all items had been manufactured from fully qualified raw material.

N Your advice of incomplete documentation and material furnished lacking W

the " chemical overcheck" requirement of paragraph NCA-3867.4(e)(2) indicates that contrary "to documentation provided by you, the listed items were manu-

+,

gerly qualified under the provisions of NCA-3867.4(parently has been im factured from unqualified" stock material which ape).

The terminology chemical overcheck" does not appear in ASME Section III and is not an accep-ted description for product analyses required to be performed on each piece of unqualified stock material used to manufacture final material.

j

GUYON ALidYS', INC.

Page 2 of 4 NCA-3867.4(e) and various Code Interpretations (III-1-77-170, III 79-107, III-2-79-16, III-80-210, III-80-211, III-82-40, & III-82-67) issued by ASNE permit acceptance.of the certification by the stock material man-ufacturer of only the requirements of the material specification which must be performed during melting, i.e., heat (ladle) analysis and melting method; and require that in addition to product analysis on each piece of stock ma-terial all other requirements of the material specification be performed on stock material and be reported.

Per the referenced Interpretations, "all other requirements" includes heat treatment when applicable, and it is required that the stock material manufacturer's material test report be furnished with CMTR's applicable to final material.

Based 'on the foregoing, the following questions apply to the items affected by your notification.

Your answers to these questions as appli-cable to each item are requested to permit additional and complete infor-mation to be provided to recipients of the material in question for their use in determination of whether the use of the material may create a sub-stantial safety hazard.

1.

Do chemical properties reported by your CMTR represent the stock ma-terial manufacturer's heat (ladle) analysis?

2.

Are samples of each piece of stock material available and traceable to each assigned and documented heat code for performance of product analyses?

3.

Can copies of original stock material melter and manufacturer's mater-ial test report traceable to each assigned and documented heat code be furnished?

4.

For final material specifications requiring heat treatment, has all stock material including stock material used to produce final items by machining been heat treated by you or your qualified subcontractor?

5.

Do physical properties test results reported by your CMTR represent results of test performed or subcontracted by you on stock material?

6.

For final material specifications requiring heat treatment, do physi-cal properties test results reported by your CMTR represent the ma-terial in its final heat treated condition as heat treated by you or your subcontractor?

7.

Have physical properties tests been performed on each piece of stock material if traceability has not been established to permit physical testing on each heat and lot of material?

8.

If physical properties tests have been performed on each heat and lot of material has objective evidence been maintained of traceability having been established?

9.

Has objective evidence been maintained of no welding or weld repairs having been performed by stock material manufacturer?

Based on the discussed review of our records we have prepared and are attaching two copies of an order / material listing which we believe is organized and more accurately contains and describes the material

CUYON dLd.dYS; INC.

Page 3 of 4 affected by your notification.

This listing reflects correction of apparent errors or omissions and is arranged in chronological order of dates of original Guyon Alloys orders and numerical order of item numbers of each Guyon Alloys order.

Our listing provides cross references to Bonney Forge order or job and item numbers shown on your listing.

The attached listing also provides a simple means for you to provide the answers to our fore-going questions by entering a "Y" for yes, an "N" for no, or a "O" for not applicable on the line for each item in the column under each question number.

Please complete the listing accordingly and return one copy of the completed listing to us as soon as possible.

The following provides a synopsis of apparent errors and omissions included in or omitted from your~ listing.

The paragraph letters in paren-theses of this synopsis are also noted on our attached listing for your ready reference.

(a)

Item 47-of our order A-28539-NW is shown on your listing as Item 77 of your Job 2805 but as Item 47 of your CMTR.

(b)

Your CMTR's identify starting material of mill heat 654C675 for Heat Code 342DD as A-106 for Item 1 of our order A-31273-N and your Job 4162 and as a A-105 for Item 1 of our order A-31305-N and your Job 4204.

The same 342DD Heat Code is certified as SA-105 by your CMIR for Item 1 of our order A-45418-LAN and your Job 4706.

(c)

Your listing identifies Heat Codes 478DD and 479DD material as Monel 400 for Item 1 of our order A-33293-NC and your Job 3542 whereas SA-182 Grade F316 material was purchased and certified by your CMTR.

(d)

Items 58 & 59 of our order A-51469-NW and Items 65 & 66 of your Job 9026 were listed by you as XXS whereas XS nipolets were pur-chased and certified by your CMTR.

(e)

Your listing identifies Heat Code BU94 material as F304 stainless for Item 79 of our order A-51469-NW and Item 86 of your Job 9026+1 whereas SA-105 nipolets were purchased and certified by your CMTR.

(f)

Heat Code 521BB is indicated by your listing as being in question for Items 106, 107, 108, 124, & 126 of our order A-51469-NW and Items 47, 48, 49, 91, & 93 of your Job 9026 whereas your CMTR's certify all or the affected portions of these items as Heat Code 521S.

(g)

Heat Code 497DD is indicated by your listing as being in question for Item 75 of our order A-52084-NW and your Job 8825 whereas your CMTR certifies this item as Heat Code 497T.

(h)

Heat Code 557B is indicated by your listing as being in question for Items 10, 21, & 22 of our order A-47698-NC and your Job 1266 but Items 11, 12, & 23 of the same order and job certified by.

your CMTR's as also being of Heat Code 557B have not been included in your listing.

(i)

Heat Code 585B is indicated by your listing as being in question for Item 17 of our order A-57619-N and your Job 0700 but Items 12, 13, 15, & 16 of the same order and job cerfified by your CMTR's as also being of Heat Code 585B have not been included in your listing.

~

, CUYCN ALL:0YO,' INC.

Pago 4 of 4 Our order A-52113-W and your Job 9978 should not have beeniincluded in your listing in as much as our order purchased commercial quality matcrial to which ASME Section III NCA-3800 requirements were not appli-ccble.

Copies of your referenced notification letter and this letter are baing furnished to recipients of the discussed material in conjunction with our notification of receipt of nonconforming material.

In accor-dance with a request by the NRC, copies are also being furnished to the Nuclear Regulatory Commision.

It is essential that we promptly receive a completed copy of our attached listing and your reply hereto in order that completeinformation can be provided for determination of final material l

disposition.

i l

=

l Very truly yours, GU ON ALL( YS INC N

I W

o g9 gMod George H. Grunthaler l

Vice President l

Technical Services 1

)

/

e e

m z

PACE 1 0F 2 BONNEY FORCE CUYON ALIAYS Item No.

Spec /

Heat OUESTION ANSWERS Order /

Item P

Description Crede Code 1E E E (5,, E E E E Job #

uo.

Order No.

No.

A 9825 14.

A-22665-W 14.

3 16" x 16" Std. WW1sts SA-105 21(F 9625 15.

15 2

18" x 16" DLtto SA-105 437K A-25409-w 45.

1 4F' x 3r Std. WW1st SA-105 389AA 0519 45.

f A-28539-W 47.

60 3/8" 31 W Half Omplires (s)

SA.105 366 2805 77.

164.

SS 3/8" et W Omplises SA-105 BR57 7805 164.

172.

55 3/8" et W Half @?h SA-105 st57 2005 172.

A-34359-W 54.

4 2" x 1" 26 Sockolats SA-182 554Z 4505 55.

F304t.

67.

1 1" x 3/4" 3t Sockolet S8-42 38715 3389 4.

i 20m3 A-31273-N 1.

3 Ifr* x 8" IR W1dolets (b)

SA-234

%2ED 4162 1.

179 S 182 478E8 3542 1.

}

A-33293-MC 1.

53 1/2" 3t SW Caglings (a)

F316 147 DLtto

.)

Ditto 479tm 3542 1.

i A-3D05-N 1.

1 12" x 8" XII WW1st (b)

SA-2%

%2!D 4204 1.

175 A-31377-N 1.

1 tr x r XM Widolet

% 105

%5ID 4282 1.

A-44917-W 100.

10 3(-3" x 1%" 34 h1aea SA-182 161A 5011 100.

F304L 101.

10 3"-4" x W St Sockolats DLtto 161A 5011 101.

102.

10 8"-6" x IV' 31 Sottoista Ditto 161A 5011 102.

103.

10 18"-ir a ik" 3t Sacholats DLeto 161A 5011 103.

104 10 36"-2tr' x ik" 3t Soc 8lalats DLtto 161A 5011 154.

A-31711-tml 306.

25 1r 3t W Naif amptings ss-us 224A 4611 306.

m00 47 %

1.

A-45418-W 1.

I 18" x 8" W Whist (b)

SA-105

%2ID A-M126-16f 2.

1 3" x 3/4" et W 1atrolet SA-182 546A 7594 2.

F316 A-51469-W 22.

19 2" 3t SW cmg11rge SA-182 uS3 9026 103.

F304 9

Ditto Ditto un3 9026 103.

SA-105 IC72 9026 65.

d 58.

50 8*-3" x 1/2" 3H Nipolats }

II SA 105 IG72 9026 66.

59.

50 36" 10" x 1/2" IN NLpolets) 70.

50 12"-8" x IV' W Ittpolats SA-105 Lf57 9026 77.

71.

50 24"-14" x 1%" mi attpolats

% 105 tr57 9026 78.

79.

20 36"-8" x 1/2" 33It taipolata (e)

SA-105 Rf94 9026 86.

9026 88.

81.

20

%"-8" x 1/2" XIX leipolats SA-105 R194 9026 90.

83.

20 6"-2V* x 1/2" IIR ttipolets SA-105 R796 106.

37 5"-3" x 3/4" 3It leipolats SA-182 1115 9026 47.

F304 9026 48.

107.

50 12"-6" x 3/4" 3H taipolats DLtto 5213 9026 49.

108.

49 36"-14" r 3/4" IH NLpoints)

Ditto 5213 9026 49.

1 DLeto Ditto 58er.

121.

10 tr-8" x 2" Mt Nipolets DLtto b912 9026 62.

9026 62.

10 Ditto DLtto 694Z 9026 91.

Ditto 5213 124.

20 17-3" x 3/4" IIM ttipolats J gg) 9026 93.

126.

20 10" 3" x 3/4" X3H teLpolets)

Ditto 5213 9150 5.

% 182 546A A-51521-W 5.

10 2%" x 3/4" et hiacs F316 8268

%9.

A-515A3-W

%9.

300 2" x 1" et SW AmArina caelines S/160 SA-105 Cit 50 9284 4.

it? IAN 859.

10 1/2" 3t threaded ampliri8s SB-164 3885 M600 9609 4.

A-55331-N 4

3 2" x 3/4" et Sockoists SA 182

%6A F316 9738 3.

SA-182 pt38 A-53595-N 17.

8 1%" 31 SW Qay11rgs D04 9738 8.

22.

7 3/4" 3t W Half omelines Ditto 3298 9775 11.

A-51972-W 11.

1 3" x 3/4" S/40 57 latrolet

% 182 329s F304 8825 75.

A-52084-W 75.

30 1/4" et threaded Caos (8)

SA-105 kg7r 0073 1.

A-52155-W 1.

3 6" S/80 x 3/4" S/40 Wielats SA-182 b828 r316L 1

r

/

.e CUTON ALLOYS FACE 2 0F 2 BONNEY FORCE Itse No.

Spec /

Heat QUESTION ANSWERS Order /

Item Order No.

No, h

Description Grade Code g { Q

{ { {

{

f{ 1 Job f No.

A 60055-tal 15.

1 3" x 1" 3t Sodotet wi82 587B 1063 15.

F306 16.

2 IV' x 3/4" et Sodoise Ditto 5878 1063 16.

A 56455-BRt 5.

25 1%" kasvi SW Flige SA-182 r.368 1079 5.

n06L A 57266-N 1.

10 3" x 1" S/40 W 14trolets W182 5878 0361 1.

n04 A-62320-W 12.

3 2" x 3/4" 7t Sodolets SA-182 5828 0389 12.

n06 A-56608-BNt 9.

7 5" x 3/4" 3t Sodotets wi82 6398 0538 9.

F316L A-47683-NC 1.

3 3/4" Hmm. Head 2hreaded Fhes SB-462 107C 1239 1.

2033 2.

4 1" Hmm. Head Threaded Fluss Mtto 1885 1239 2.

A-600f.4-!RI 17.

10 1" x 3/4" et Sockolets SA-182 5858 0601 17.

F304 A-47696-NC 10.

4 1%"-1%" x 1/2" 3t Sodolets h 182 557B 1266 10.

F316 2%"-2" x 1/2" 3t Sodolets } I 11.

4 Ditto 557B 1266 11.

12.

4 8"-3" x 1/2" 3t Sodolets J Mtto 5575 1266 12.

17, 4

1%" x 1" 36 Sodolets DLtto 170C 1266 17.

18.

4 2" x 1" 3I Sodolets DLeto 170C 1266 18.

19.

7 2V' x 1" 3t Sodolets Mtto 170C 1266 19.

20.

4 3V'-3" x 1" 3t Sodolets Mtto 170C 1266 20.

21.

4 1%"-Ik" x 1/2" S/40 (See Widolets Mtto 557B 1266 21.

22.

4 2%"-2" x 1/2" S/40 (Std) Wi&1sts DLtto 557B 1266 22.

23.

4 8"-3" x 1/2" S/40 (Std) Wielses (h)

Ditto 557B 1266 23.

26.

4 1%" x 1" S/40 (Std) Widolets Ditto 170C 1266 26.

27.

4 2"

x 1"

S/40 (Std) W16tets Ditto 170C 1266 27.

28.

4 2%" x 1"

S/40 (Std) W1dotets Ditto 170C 1266 23.

29.

4 3k"-3" x 1" S/40 (Std) Widolats Ditto 170C 1266 E

A-47701-NC 2.

80 3" x 1/2" et Sodolets wl82 163C 0652 2.

n16 A-57619-N 12, 25 tr-6" x 1" 3t Sodelets W182 5858 0700 12.

n06 13.

25 5"-4" x 1" Ditto DLeto 5855 0700 13.

III 15.

25 24" x 1" Ditto Ditto 5858 0700 15.

16.

5 2" x 1" Ditto Ditto 585B 0700 16.

17.

5 IV' x 1" DLeto Mtto 5858 0700 17.

21.

25 36"-14" s 3/4" 3! Sodotats Ditto 5825 0700 21.

A-56756-BNI 4.

10 3" x 1" et Sndolets wi82 580B 0753 4

F304 5.

20 Y' x 1/2" et Sodelats Ditto 5825 0753 5.

A-57698-N 21.

1 10"-6" x 1" 21 Sodolet wl82 5858 0808 21.

F306 A-62689-W 6.

20 1r x 3/4" et SW Elbolets 82 246C 0877 6.

7.

3 6" x 3/4" et SW Elbolets tto ma 0s77 7.

5 Ditto Ditto 246C 0877 7.

4 Ditto Ditto 5565 0877 7.

8 Ditto Ditto L70C 0877 7.

A-47796-NC 1.

8 10"-6" x 1" Jt Sodotets SA-403 5858 0918 1.

W306 3.

8 Flat x 1" 3t Sodotete Ditto 5855 0018 3.

A-62803-NW 1.

3 4" x 2" S/80 widolets wl82 F53B 2035 1.

D04L

CUYCN ALLOYS, INC.

EXHIBIT I

. Order No. 320 3170-90 Purchaser:

ACEngineering Korea Heavy Industries & Construction Co., Ltd.

Seoul & Kyungsangnam-Do, Korea Proj ect:

Unidentified SA-182 Grade F304, ASME Section III Class 2, 1977 Edition /

Winter 1978 Adden'd'a' Item #11-8.

'8 pes. 1 1/2" 3000# SW Coupling, Bonney Forge Heat Code BM58

  1. 11-13.

7 pes. 3/4" 3000# SW Half Couplings, Bonney Forge Heat Code 329B i

Date shipped:

4/30/82 (G/A A-53595-N) e

CUYCN. ALL@YQ, INC.

EXHIBIT I

Order No. 70996 Purchaser:

Arkansas Power & Light Co.

Proj ect :

Arkansas Nuclear One to SA-182 Grade F316L, ASME Section.III Class 3, 1980 Edition /

Winter 1980 Adden'da' Item #6.

7 pes. 5" x 3/4" 3000# Sockolets, Bonney Forge Heat Code 639B Date shipped:

8/26/82 (G/A A-56608-BRN)

CUYGN AL1.@Y8, INC.

EXHIBIT I

Order No. 7220-F-54255Q Purchaser:

Bechtel Power Corporation Agents for Consumers Power Co.

Proj ect:

Midland Nuclear Plant Consumers Power Co.

SA-182 Grade F316, ASME Section III Class 1, 1980 Edition /

Winter 1980 Addenda ~

Item #5.

10 pes. 2 1/2" x 3/4" 6000# Sockolets, Bonney Forge Heat Code 546A Date shipped:

12/22/81 (G/A A-51521-NW)

CUYCN ALLOYS,' INC.

EXHIBIT' I Orders No. -8031-F-50970 8031-F-56377 Purchaser:

Bechtel Power Corporation Agent for Philadelphia Electric Co.

Proj ect:

Limerick Generating Station Philadelphia Electric Co.

Order-8031-F-50970 SA-182 Grade F316L, ASME Section.III. Class:1, 1980 Edition /

Winter 1981' Addenda' Item #1.

.3 pes. 6" Sch. 80 x 3/4" Sch.40 Weldolets, Bonney Forge Heat Code 482B Date shipped:

6/15/82 (G/A A-52155-NW)

Order 8031-F-56377 SA-182 Grade ~F304L, ASME Section III Class 1, 1980 Edition /

Sununer 1982 Addenda' Item #1.

3 pes. 4" x 2" Sch. 80 Weldolets, Bonney Forge Heat Code 653B Date shipped:

12/23/82 (G/A A-62803-NW)

.--,e--,c-.___

/

C

.CUYCN ALL@Y, INC.

EXHIBIT I

Order No. GPN 3231 Purchaser:

Bell-Schneider, Joint Venture Proj ect:

Ginna Station Rochester Gas & Electric Corp.

SA-182 Grade F316, ASME Section III Class 1, 1980 Edition /

Winter 1981 Addenda Item #4.

3 pes. 2" x 3/4" 6000# Sockolets, Bonney Forge Heat Code 546A Date shipped:

3/10/82 (G/A A-55531-N) h

CUYGN ALLOY, INC.

EXHIBIT I

Order No.

B-16316 Purchaser:

Carolina Power & Light Co.

Proj ect:

swick Steam Electric Station SB-462 Alloy 20 (20CB3), ASME Section III Class 2, 1980 Edition / N Winter 1981 Addenda Item #2.

3 pes.. 3/4" Hex Head Threaded Plugs, Bonney Forge Heat Code 107C

  1. 3.

4 pes.

1" Ditto 188B Date shipped:

11/15/82 (G/A A-47683-NC)

UYCN ALLGYS, INC.

~

EXHIBIT I

Orders No.

H-40186 & H-41349 Purchaser:

Carolina Power & Light Co.

Proj ect:

Shearon Harris Nuclear Power Plant Order H-40186 SA-182 Grade F316, ASME Section III Class 2, 1974 Edition / Winter 1976 Addenda em #5.

80 pes. 3" x 1/2" 6000f Sockolets, Bonney Forge Heat Code 163C Date shipped:

11/29/82 (G/A A-47701-NC)

Order H-4134 SA-182 Gra e F316, ASME Section III Class 2, 1980 Edition / Winter 1981 Adden Item #10.

4 pes.

%"-1k" x %" 3000# Sockoletsi Bonney Forge Heat Code 557B 11.

4 pes. 2

"-2" x %"

v' Ditto 557B 12.

4 pes. 8" -3" x 1/2-

Ditto 557B 17, 4pcs. 1%" x 1" Ditto 170C 18.

4pcs. 2"jx 1" Ditto 170C 19.

7 pes. 2 " x 1" Ditto 170C 20.

4pcs. 3%"-3" x 1" Ditto 170C 21.

4 pes. 1 "-1%"x%" Std.(S/40) Weldolets Bonney Forge Heat Code 557B 22.

4 pes. 2 "-2" x Ditto 557B 23.

4pcs. 8"-3" x 1/2" Ditto 557B 26.

4pcs. 1 " x l','.

Ditto 170C 27.

4 pes 2" x 1" Ditto 170C 28.

4 pes. 2 " x 1" Ditto 170C 29, 4 pes. 3%"-3" x 1" Ditto 170C Date shipped: 10/29/82, 11/28/82, 12/29/82, & 1/18/83 (G/A A-47698-NC)

CUYGN ALLOYS, INC.

2 EXHIBIT _I i

Order No. 256454 Purchaser:

Commonwealth Edison Company Proj ect:

Braidwood Station i

SA-182 Grade F304, ASME Section III Class '2,1974 Edition /Surmer 1975 Mdana Item #52.

37 pes. 5"-3" x 3/4" XS (3000#) Nipolets, Bonney Forge Heat Code 521S j

  1. 53.

50 pes. 12"-6" x 3/4" Ditto 521S l

  1. 54. 49 pes. 36"-14" x 3/4" Ditto 521S l

1pc 36"-14" x 3/4" Ditto 588Z

  1. 67.

10pcs. 10"-8" x 2" Ditto 694Z 10 pes, 10"-8" x 2" Ditto 491Z SA-105, ASE Section III Class 2,1974 Edition /Simmar 1975 Addenda Itan #70. 50 pes. 8"-3" x 1/2" XS (3000#) Nipolets, Benney Forge Heat Code BG72

  1. 71.

50 pes. 36"-10" x 1/2" Ditto BG72

  1. 82. 50 pes. 12"-8" x 1 1/2" Ditto BJ57
  1. 83.

50 pes. 24"-14" x 1 1/2"

-Ditto U57 i

SA-182 Grade F304, ASME Section III Class 2,1974 Edition /Simmar 1975 Mana Item #93.

19 pes. 2" 3000# SW Couplings, Bcxiney Forge Heat Code BK93 9 pes. 2" 3000#

Ditto HW3 SA-105, ASME SecHm III Class 2,1974 Edition /Simmar 1975 MAana 1

Item #119. 20 pes. 36"-8" (36"-14") x " XXS (6000#) Nipolets, Bconey Forge' Heat Code BU94

  1. 121. 20pcs. 36"-8" (12"-6") x 1/2" Ditto BU94
  1. 123. 20 pes. 6"-2%" (5"-3") x 1/2" Ditto BU94 SA-182 Grade F304, ASME Secticn III Class 2,1974 Editicn/Stamer 1975 'Mana

~

Itan #124. 20 pes.10"-3" (12"-6") x 3/4" XXS (6000#)Nipolets, Bonney Forge Heat Code 521S

  1. 126. 20pcs.10"-3" (5"-3") x 3/4" Ditto 521S Dates shipped:

11/17, 11/18, & 11/25/81 (G/A A-51469-NW)

I

r-CUYGN ALI,.QYS, INC.

EXHIBIT I Order No. E2936-368 Purchaser:

Dravo Corporation Proj ect :

Seabrook Station Public Service Co. of New Hampshire SA-182 Grade F316, ASME Section III Class 2* 1974 Edition /

Summer 1974' Addenda Item #6.

20 pes. 10" x 3/4" 6000# SW Elbolets, Bonney Forge Heat Code 246C

  1. 7.

3 pes. 6" x 3/4" 6000# SW Elbolets, Bonney Forge Heat Code 651B 5 pes.

Ditto 246C 4 pes.

Ditto 556B 8 pes.

Ditto 170C Date shipped:

2/16/83 (G/A A-62689-NW)

  • With Class 1 Examination.

CUYCN ' ALLOYS, INC.

EXHIBIT I

Order No. 2BV-58A Release =#'s 95, 113, & 124 Purchaser:

Duquesne Light Company Stone & Webster Engineering Corp., Agent Proj ect:

Beaver Valley Power Station - Unit No. 2 Release #95 SA-182 Grade F316, ASME Section III Class 2, 1971 Edition /

Winter 1972 Addenda Item #2.

Ipc. 3" x 3/4" 6000# SW Latrolet, Bonney Forge Heat Code 546A Date shipped:

8/25/81 (G/A A-34126-NW)

Release #113 SA-182 Grade 7304, ASME Section III Class 2, 1971 Edition /

Winter 1972 Addenda Item #11. Ipc. 3" x 3/4" S/40 BW Latrolet, Bonney Forge Heat Code 329B Date shipped:

5/24/82 (G/A A-51972-NW)

Rplease #124 SA-182 Grade F304, ASME Section III Class 2, 1971 Edition /

Winter 1972 Addenda Item #12. 3 pes. 2" x 3/4" 3000# Sockolets, Bonney Forge Heat Code 582B Date shipped:

8/24/82 (G/A A-62320-NW)

r-C;UYCN AL'LOYb, INC.

~

EXHIBIT I

Order No. 12210-57767 Purchaser:

Gulf States Utilities Company Stone & Webster Engineering Corp., Agent Proj ect:

River Bend Nuclear Power Station SA-182 Grade F304L, ASNE Section III Class 2, 1977 Edition /

Summer 1978 Addenda Item #5.

25 pes. 1 1/2" SW Round Head Plugs, Bonney Forge-Heat Code 436B Date shipped:

8/12/82 (G/A A-56455-BRN) d

CUYCN AO.GYU, INC.

EXHIBIT I

Order No. 11516 Purchaser:

Peter Kiewit Sons' Co.

Proj ect:

W.P.P.S.S. Units 3 & 5 t

SA-182 Grade F304, ASME Section III Class 2, 1977 Edition /

Samar 1978 Addenda Item #22. Ipc. 3" x 1" 3000# Sockolet, Bonney Forge Heat Code 587B

  1. 25. 2 pes. 1 1/2" x 3/4" 6000# Sockolet, Bonnay Forge Heat Code 587B Date shipped:

8/3/82 (G/A A-60055-LAN) h 7

I 1

P

F CUYCN ALLOYd, INC.

EXHIBIT I

Order-No. WP3-10080 Purchaser: -Louisiana Power & Light Company Ebasco Services, Inc., Agent Proj ect:

Waterford SES Unit No. 3-(

SA-182 Grade F304, ASME Section III Class 2, 1980 Edition /

Stanmer 1980 Addenda Item f3.

10 pes. 3" x 1" 6000# Sockolets, Bonney Forge Heat Code 580B

  1. 4.

20 pes. 3" x 1/2" 6000f Sockol'ets, Bonney Forge Heat Code 582B Date shipped:

10/19/82 (G/A A-56756-BRN) 4

. - ~

CUYGN ALLOYC, INC.

EXHIBIT I

Order No. 344222 Purchaser:

Long Island Lighting Company c/o Stone & Webster Engineering Corp.

Proj ect:

Shoreham Nuclear Power Station - Unit 1 SA-105, ASME Section III Class 2, 1977 Edition / Winter 1977 Addenda Item #3.

Ipc. 18"x16" Std. Wt. Weldolet, Bonney Forge Heat Code 437K Date shipped:

8/31/78 (G/A Inv. A-22665-NW)

CUYCN ALLOYil, INC.

EXHIBIT I

Order No..NMP2-FPO-12345 Release #'s 38 & 41 Purchaser:

Niagara Mohawk Power Corporation Stone & Webster Engineering Corp., Agent

. Proj ect :

Nine Mile Point Nuclear Power Station - Unit No. 2 Release #38 SA-182 Grade F304, ASME Section III Class 2, 1974 Edition /No Addenda Item #12.

25 pes.10"-6" x 1" 3000# Sockolets, Bonney Forge Heat Code 585B -

  1. 13.

25pcs. 5"-

4" x 1" Ditto 585B

  1. 15.

25 pes'. 2 1/2" x 1" Ditto 585B

  1. 16.

5 pes. 2" x 1" Ditto,t

-585B

  1. 17.

Spes. 1 1/2" x 1" Ditto 585B >

  1. 21.

25 pes. 36"-14" x 3/4" Ditto 582B -

Dates shipped: Items 12, 13, 15, & 16 - 12/16/82 Items 17, and 21 - 11/12/82 (G/A A-57619-N)

Release #41 SA-182 Grade F304, ASME Section III Class 2, 1974 Edition /No Addenda Item #21. Ipc. 10"-6" x 1" 3000# Sockolet, Bonney Forge Heat Code 585B -

-Date shipped:

11/29/82 (G/A A-57698-N)

c.

CUYCN ALLGYS, INC.

EXHIBIT I

Order No. 12179-15761 Purchaser:

Northeast Utilities Service Co.

Stone & Webster Engineering Corp., Agent Proj ect:

Millstone Nuclear Power Station - Unit No. 3 SA-182 Grade F304, ASME Section III Class 2, 1971 Edition /

Summer 1973' Addenda Item #1.

10 pes. 3" x 1" Sch. 40 B.W. Latrolets, Bonney Forge Heat Code 587B Date shipped:

8/19/82 (G/A A-57266-N)

CUY' N ALLOYD, INC.

s EXHIBIT I

Order No. 12045-3-P-307B Rev. 2 Rel. 3 Purcheser: Overseas Bechtel, Inc.

Agents for Korea Electric Company Proj ect:

Korea Nuclear Units 5 & 6 SB-164 Grade 400 (70Ni-30Cu), ASME Section III Class 3, 1977 Edition / Summer 1978 Addenda Item #306.

25 pes. 1 1/2" 3000f SW Half Couplings, Bonney Forge Heat Code 224A Date shipped:

2/19/81 (G/A A-31711-LAN)

CUYCN AL;L@YS, INC.

EXHIBIT I

Order No.

11-15676-64150 j

Purchaser:

Pittsburgh-Des Moines Corporation l

Proj ect:

Hope Creek Generating Station - Unit 2 Public Service Electric & Gas Co.

SA-105, ASME S~ecti~on III Class 2, 1974 Edition / Winter 1974 Addenda Item #1.

Ipc. 18"x8" XH Weldolet, Bonney Forge Heat Code 342DD Date shipped:

10/25/80 (G/A A-45418-NW) l i

c

' CUYCN ALi,0Y5, INC.

EXHIBIT I

Order No.

10855-F-31894Q Purchaser: Public Service Electric & Gas Co.

Bechtel Power Corporation, Agent Proj ect:

Hope Creek Generating Station SA-105, ASME Section III Class 2, 1980 Edition / Winter 1981 Addenda Item #349 300 pes. 2" x 1" 6000# SW Reducing Couplings Sch. 160, Bonney Forge Heat Code CH50 Date shipped:

4/8/82 (G/A A-51563-NW)

CUYCN All.GYd,.INC.

EXHIBIT I

Orders No. J103-477, J103-489, & J103-491 Purchaser: Reactor Controls, Inc.

Proj ect:

Enrico Fermi Nuclear' Station - Unit No. 2 Detroit Edison Company Order J103-477 SA-234 Grade WPB, ASME Section III Class 2, 1977 Edition / Summer 1978 Addenda Item #1.

3 pes. 10"x8" XH Weldolets, Bonney Forge Heat Code 342DD Date shipped:

5/2/80 (G/A A-31273-N)

Order J103-489 SA-234 Grade WPB, ASME Section III Class 2, 1977 Edition / Summer 1977 Addenda Item #4.

Ipc. 12"x8" XH Weldolet, Bonney Forge Heat Code 342DD Date shipped:

5/13/80 (G/A A-31305-N)

Order J103-491 SA-105, ASME Section III Class 2, 1977 Edition / Summer 1978 Addenda Item #3.

Ipc. 10"x8" XH Weldolet, Bonney Forge Heat Code 345DD Date shipped:

9/25/80 (G/A A-31377-N)

I CUYSN ' ALL.GYS, INC.

EXHIBIT I

Order No. 7290 F.S.

Purchaser:

Robertshaw Controls Company Fulton Sylphon Division Proj ect:

Hatch Units 1 & 2 Georgia Power Company SA-403 Grade WP304, ASME Section III. Class 2, 1980 Edition /

Winter 1981~ Adden'd'a Item #2.

8 pes. 10"-6"x1" 3000# Sockolets (N-35781-A2) Bonney Forge Heat Code 585B

  1. 3.

8 pes. Flat x 1" 3000# Sockolets (N-35781-B2) Bonney Forge Heat Code 585B Date shipped:

12/2/82 (G/A A-47796-NC)

NUYCN ALLDYC, lNC.

i EXHIBIT I

Order No. Il917-3-P-307A Rev. 28 Purchaser:

Taiwan Power Company C/0 Overseas Bechtel, Inc.

Proj ect:

Taipower Nuclear Units 5 & 6 (Maanshan Nuclear Power Station Units 1 & 2)

SB-164 Alloy 400 (Monel 400), ASME Section III Class 3, 1977 Edition / Winter 1977 Addenda Item #859.

10 pes. 1/2" 3000# Threaded Couplings, Bonney Forge Heat. Code 388B Date shipped:

6/24/82 (G/A A-44669-LAN)

f CUYCN ALLOYS; INC.

EXHIBIT I

Order No. 80PA3-254387 Purchaser:

Tennessee Valley Authority Proj ect:

Browns Ferry Nuclear Plant SA-182 Grade F316, ASME Section III Class 2, 1977 Edition / Winter 1979 Addenda Item-#2.

53 pes. 1/2" 3000# SW Couplings, Bonney Forge Heat Code 478DD 147 pes.

Ditto 479DD Date shipped:

6/25/80 (G/A A-33293-NC)

(a

f-f CUYCN _ ALLOYS, INC.

4 EXHIBIT I

Order-No.

78KA3-822825 RD's #

703600 & 703767 Purchaser:

Tennessee Valley Authority Proj ect:

Hartsville Nuclear Plant T

RD# 703600 SA-182 Grade F304L, ASME Section III Class 2, 1977 Edition / Summer 1977 Addenda Item #160.

2' pes. 2".x 1" 3000# Sockclets, Bonney Forge _ Heat Code 554Z Data Shipped:

10/20/80 (G/A Inv. A-34359-NW)

SB-462' Alloy 20CB3, ASME Section III Class 2, 1977 Edition /Sunmer 1977 Addenda Item #213.

1 pc. 1"x3/4" 3000# Sockolet, Bonney Forge Heat Code 387BB Data shipped:

6/13/80 (G/A Inv.'A-34359-NW)

RD# 703767 SA-182 Grade F304L,.ASME Section III Class 2, 1977 Edition / Summer 1977 Addenda Item #100, 10pcs. 3%"-3"x1k" 3000# Sockolets, Bonney Forge Heat Code 161A

101, 10 pes. 5"-4" xl%"

Ditto 161A l

102.

10 pes. 8"-6" x1%"

Ditto 161A l

103.

10 pes. 18"-10"xl%"

Ditto 161A 104.

10 pes. 36"-20"xl%"

Ditto 161A Date shipped:

10/23/80 (G/A A-44917-NW)

f CUYCN ALLOYO, INC.

EXHIBIT I

Orders No.

78KA2-823188-1

/8KA3-822825 RD's # 616916 & 703746 Purchaser:

Tennessee Valley Authority Project:

Phipps Bend Nuclear Plant i

Order 78KA2-823188-1

, SA-105, ASME Section III Class 3, 1977 Edition / Summer 1978 Addenda Item #45.

Ipc. 48"x30" Std. Wt. Weldolet, Bonney Forge Heat Code 389AA Date shipped:

12/11/78 (G/A A-25409-NW) i Order 78KA3-822825 RD # 61691.6 SA-105, ASME Section III Class 2,'1977 Edition / Summer 1977 Addenda Item #75.

50 pes. 3/8" 3000# SW Half Couplings, Bonney Forge Heat Code BN66 Date shipped:

5/12/80 Item #212. 50 pes. 3/8" 6000# SW Couplings, Bonney Forge Heat Code BR57 Item #219. 50 pes. 3/8" 6000# SW Half Couplings, Bonney Forge Heat Code BR57 Date shipped:

2/25/80 (G/A Inv. A-28539-NW)

RD # 703746 SA-182 Grade F304L, ASME Section III Class 2, 1977 Edition / Summer 1977 Addenda Item # 96.

2 pes. 2"xl" 3000# Sockolets, Bonney Forge Heat Code 554Z Data shipped:

10/20/80 (G/A Inv. A-34359-NW)

CUYIN ALLGYO, INC.

EXHIBIT I

I l

Order No. 51899 Purchaser:_ Washington Public. Power Supply System i

Proj ect:

W.P.P.S.S.

.WPN-2 r

SA-182 Grade F304, ASME Section III Class 1, 1971 Edition /

Winter 1973 Addenda Item #3.

10 pes. 1" x 3/4" 6000# Sockolets, Bonney Forge Heat Code 585B Date shipped:

12/3/82 (G/A A-60044-LAN) 1 1

l

__