ML20113C600

From kanterella
Jump to navigation Jump to search
Discusses Bonney Forge Part 21 Rept.S&W Notified That Evaluation Required Re Matl Delivered to Shoreham Not Meeting Nca 3967.4(e)(2) Requirements
ML20113C600
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 03/26/1984
From: Pentz L
PERMUTIT CO., INC.
To: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-84 NUDOCS 8504110713
Download: ML20113C600 (2)


Text

'*

  • y W

cr PERMUTIT' A

CON WATER & WASTE TREATMENT FOR INDUSTRY & MUNICIPALITY THE PERMUTIT COMPANY INC., P.O. BOX 1549,1915 OLD PHILADELPHIA PIKE. LANCASTER. PA.17604 PHONE: (717) 394 6801. TELEX: 848-430 y q PaJ u b

E March 26, 1984 Mr. Edward L. Jordan, Director Division of Emergency Preparedness and Engineering Response Office of Inspection and Enforcement Nuclear Regulatory Commission Washington, D.C.

20555 Ref:

Your letter 3/16/84 G&W-Boney Forge-D.L. Kale letter 2/15/84

Dear Mr. Jordan:

By copy of this letter, we inform your office that Permutit Company has fulfilled responsibilities as required by Part 21 of Title 10 of the Code of Federal Regulations (10 CFR 21).

As the attached letter shows, we have notified the purchaser, Stone & Webster Engineering Corp., that an evaluation of subject discrepant material is required and that Permutit Company is to be notified of disposition.

Should you require any further information, please contact ~the undersigned.

Very truly yours, C,

Larr C. Pentz Quality Assurance Manager

)

/csb g

Enclosure 4

g

  1. 7 h\\

Y gS,O41%$INha p

9 e

.9 O

PERMUTIT'

  1. O #"

WATER & WASTE TREATMENT FOR INDUSTRY & MUNICIPALITY THE PERMUTIT COMPANY INC, P.O. BOX 1549,1915 OLD PHILADELPHIA PlKE. LANCASTER. PA.17604 PHONE: (71D 394-6801, TELEX: 848-430 l

March 26, 1984 Mr. R. T.

Perra Assistant Supervisor - Field Q.A.

Stone & Webster Engineering P.O. Box 604 Wading River, New York 11792

Dear Mr. Perra:

Enclosed please find a copy of a 2/15/84 letter from Mr. D. L. Kale, Q.A. Manager of G&W-Bonney Forge in regards to material supplied to Permutit Company and subsequently supplied to Stone & Webster, which does not meet the require-ments of NCA 3967.4(e)(2).

This letter from G&W-Bonney Forge is in reference to a 6-1/2" thermowell supplied to Stone & Webster and identified:

Permutit Job:

A173D-18408 l

S&W Job: 11600.02 l

Shoreham Nuclear Pwr. Stn.-Unit 1 l

Permutit Serial No: N-2700 l

S&W Tag No: 1Z91*TW940A O&W-Bonney Forge Heat No: 379BB Also find enclosed a letter from Mr. E.L. Jordan of the NRC which requires Permutit Company to inform the licensee / purchaser of the material discrepancies in order that an evaluation can be performed to determine whether the material can be used or must be replaced.

The following must be informed of your disposition:

Mr. D.L. Kale Mr. Larry C. Pentz Quality Control Manager Quality Assurance Manager G&W-Bonney Forge Permutit Company 201 West Mount Street 1915 Old Philadelphia Pike l

Carlinville, Illinois 62626 Lancaster, PA 17604 l

l Very truly yours, c.

Larr-C. Pentz Quality Assurance Manager

/csb L

r*;vdarwert __._____