ML20113B276

From kanterella
Jump to navigation Jump to search
Forwards Affidavit Providing Answers to Questions in 960502 NRC Demand for Info Submitted as Result of NRC Investigation
ML20113B276
Person / Time
Site: FitzPatrick 
Issue date: 05/29/1996
From: Peter Thompson
AFFILIATION NOT ASSIGNED
To:
NRC OFFICE OF ENFORCEMENT (OE)
Shared Package
ML20113A902 List:
References
NUDOCS 9606270031
Download: ML20113B276 (3)


Text

..-

9' May 29,1996 Director Office Of Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555 i

Subject IA 96-022 Demand ForInformation Gentlemen:

1 I am in receipt of your Demand For information (DFI) dated May 2,1996. The DFI sought a response to four specific questions plus any additionalinformation that I wish the Nuclear Regulatory Commission (NRC) to consider in this matter.-

I have answered the questions in the order in which they have been posed and have annexed a Swom Affidavit.

Very Truly Yours Paul Thompson cc:

Assistant General Council for Hearings and Enforcement U.S. Nuclear Regulatory Commission, Washington, D.C. 20555 Regional Administrator i

U.S. Nuclear Regulatory Commission, Region 1, 475 Allendale Road, King of Prussia, PA 19406 9606270031 960620 PDR ADOCK 05000333 P

PDR

AFFIDAVIT OF PAUL THOMPSON

{

Paul Thompson, being duly swom, deposes and says:

A.

I am not currently employed by an NRC licensed nuclear power facility.

B.

I admit that I instructed a person to sign into a radiologically controlled area under a different name and use a different person's dosimetry. This was done to expedite access to the area with the escorted visitor.

C.

In order to demonstrate that the NRC should have confidence that I will comply with required licensee procedures if employed in a NRC regulated activity in the future, I request that the following be taken into consideration:

1.

Upon being asked, by New York Power Authonty (NYPA) about inconsistencies in the Radiologically Controlled Area (RCA) log i immediately told the NYPA supervisors what I had done, how I had done it, and why I had done this. The information was provided again to NYPA security personnel and again to the NRC investigator who was assigned to the case. At no time was there any attempt to cover up or to distort the facts in any way. I believe that all parties involved in the investigation will confirm this fact.

2.

In the many years that I have been employed in the industry, this action is the only blemish on my work record. I believe this helps demonstrate that this incident is the result of an isolated error in judgement rather than a general disregard for licensee procedures.

D.

As a result of my actions I was denied access to the James A. Fitzpatrick Nuclear Power Plant ( and therefor all nuclear power plants ) for a period of one year. This disciplinary action did result in hardship and difficulty for my employer and myself. I did make a serious error in judgement, I have admitted it fully and have been disciplined for this action.

4

iri closing, I would like to say how sorry I am for the inconvenienm and distress I have 1

caused the New York Power Authority, the NRC and my employer. I deeply regret my actions. I understand the seriousness of this matter and assure you that tr sre will be no reoccurrence.

Should you require any clarification of my statements or any additionalinformation to assist your review of this matter, please do not hesitate to contact me.

Paul Thompson Swo e99gto before me this day of May,1996 l ^ ' ' ' ' ' * * * * * * * * * * * * "-;

e ARLENE J JSNNINGS L

i Notory Pvt.1c Stota of New Yoric e

d NO. Er23297 4

QuoMedin oVEENS COUNTY t

4 ; My Comminon Expires JAN 31,19 j

7 No6rgublic

/

a ' -'

)

l l

4

!4 u-s i

Mr. Paul Thompson DISTRIBUTION:

PUBLIC SECY CA JTaylor, EDO JMilhoan, DEDR JLieberman, OE TNartin, RI FDavis, OGC WRussell, NRR RZimmerman, NRR Enforcement Coordinators RI, RII, RIII, RIV BBeecher,GPA/PA GCaputo, 01 DBangart, OSP LNorton, OIG EJordan, AE00 OE:Chron OE:EA DCS NUDOCS DVito, RI DScrenci, PAO-RI (2)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector - FitzPatrick Region I Docket Room (with concurrences) 260005 h

I

-