Commonwealth Edison one First National Plaz, Chicago. lilinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690 March 27, 1985 Mr. Harold R. Denton, Director Office of tAJclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
LaSalle County Station Units 1 and 2 Environmental Qualification of Electrical Equipment NRC Docket Nos. 50-373 and 50-374 References (a): January 8, 1985 letter from J. G.
Marshall to H. R. Denton.
(b): January 30, 1985' letter from J. G.
Marshall to H. R. Denton.
(c): February 5, 1985 letter from J. G.
Marshall to H. R. Denton.
(d): February 22, 1985 letter from J. G.
Marshall to H. R. Denton.
(e): Telecon of March 4,1985 between J. G.
Marshall to Dr. A. Bournia.
(f): Meeting at FRR Offices in Bethesda on March 25, 1985.
Dear Mr. Denton:
During a meeting at your offices on March 25 (Ref. (f)), we discussed the commitments made in support of our request for extension on schedular requirements of 10 CFR 50.49(g) for LaSalle County Station contained in Reference (a). This letter is in response to your request for clarification at that meeting.
The following commitments are in addition to those contained within the referenced letters.
Many of the individual components for which extension is requested have delivery dates to the site after the March 31, 1985 deadline. We anticipate receipt of those items beginning in April and continuing through August. We intend to install those items which can be completed during power operation as they become available.
8504050222 850327 t
PDR ADOCK 05000373 h
P PDR
j_
'H. R. Denton' ' March 27, 1985 As you recall, we indicated that for LaSalle Unit 2 certain components requiring installation during an outage will not be available at the site until after startup following the current surveillance /EQ modification outage.
Unless this work can be accomplished during a subsequent unplamed outage, Commonwealth Edison commits to shut down Unit 2 to complete this work prior to November 30, 1985.
Should you have any questions concerning this matter, please contact this office.
~
Very truly yours, MM Cordell Reed Vice President im I
t 9927N 4
-