_ _ _ _ _ _ _ _ _ _ _

4 PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 PHILADELPHI A. PA.19101 1215)841-4502 March 28, 1985 vicenesior r ENGINES WING AND NERE ARCH Mr. A. Schwencer, Chief Docket Nos.: 50-352 Licensing Branch No. 2 U. S. Nuclear Regulatory Cmmission Washington, D.C.

20555

SUBJECT:

Limerick Generating Station, Units 1 Satisfaction of License Condition 2.C(5)

REFERENCE:

Facility Operating License NPF-27, Limerick Generating Station, Unit 1 FILE:

GOVT 1-1 (NRC)

Dear Mr. Schwencer:

This letter is to confirm actions taken to satisfy license condition 2.C(5) of the Limerick Unit 1 Operating License NPF-27.

License Condition 2.CCS) requires that prior to March 31, 1985, we are to either submit additional Information Justifying the calculated bounding drywell equipment qualification temperature profile used or we are to update all portions of the Equipment Qualification Report Record sheets to reflect the generic bounding temperature profile in NUREG-0588.

PECo has reviewed the environmental qualification of all electric equipment which is identified in Appendix B of the LGS Environmental Qualification Report (EQR) and which is located in primary containment against the NUREG-0588 temperature proflie. The results of this review conclude that the equipment is environmentally qualified to the NUREG-0588 generic profile. All environmental qualification flies for this equipment have been updated, including revision of the Equipment Qualification Review Record (EQRR), to reflect the use of the appropriate temperature proflie.

Based on the above actions, License Condition 2.C(5) has been satisfied.

Sincerely, g4020263850328 P

ADOCK 05000352 PDR JWC/dg/03228506 Copy to: (See Attached Service List)

Q l

r:

cc: Judge Helen F. Hoyt Judge derry Harbour Judge Richard F.' Cole Troy B. Conner, Jr., Esq.

Ann P. Hodgdon, Esq.

Mr. Frank R. Romano Mr. Robert L. Anthony Ms. Phyllis Zitzer Charles W. Elliot, Esq.

Zori G. Ferkin, Esq.

Mr. Thomas Gerusky Director, Penna. Emergency Management Agency Angus R. Love, Esq.

David Wersan, Esq.

Robert J. Sugarman, Esq.

Martha W. Bush, Esq.

Spence W. Perry, Esq.

Jay M. Gutierrez, Esq.

Atomic Safety & Licensing Appeal Board Atomic Safety & Licensing Board Panel Docket & Service Section Mr. James Wiggins Mr. Timothy R. S. Campbell i

i

- -.. -