Forwards Annual Report on CE ECCS Codes and Methods for 10CFR50.46 W/ Corrections
ML20112G446
Person / Time
Site: Waterford 
Issue date: 06/10/1996
From: James Fisicaro
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20112G450 List:
References
W3F1-96-0086, W3F1-96-86, NUDOCS 9606120001
Download: ML20112G446 (2)


Text

. _. - ~ -. _...

,/

Enti gy Operatims,Inc.

Killona, LA 70066 Tel 504 739 6242 es J. Fisicaro "ta"J*

W3F1-96-0086 A4.05 PR June 10,1996 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No.:50-382 License No. NPF-38 Annual Report on CE ECCS Codes and Methods for 10CFR50.46 Gentlemen:

)

This submittal is being made in accordance with 10CFR50.46 in that an error was

.found and corrected in 1995 in the ABB Combustion Engineering evaluation model used for Emergency Core Cooling System (ECCS) analyses. The error was in the

. input processing for the COMPERC-Il refill /reflood code for large break LOCA analysis.

Correction of the error in COMPERC-Il had no effect on the peak cladding temperature (PCT) for the large break LOCA. The sum of the absolute magnitude of the temperature changes for the large break LOCA from all reports to date continues to be less than 1 F. No other error corrections were made in 1995.

A copy of CENPD-279, Supplement 7, entitled " Annual Report on CE ECCS Codes and Methods for 10CFR50.46," is attached, which addresses the year 1995 error and correction that is identified above.

I#

4 /> L 120003 9606120001 960610 PDR ADOCK 05000382 P

PDR

Annual Report on CE ECCS Codes and Methods for 10CFR50.46 W3F1-96-0086 Page 2 June 10, 1996 If you should have any questions regarding this submittal, please contact me or Tim Gaudet at (504) 739-6666.

Very truly yours, i

J.J. Fisicaro Director Nuclear Safety JJF/RWP/tmm Attachment j

cc:

L.J. Callan, NRC Region IV C.P. Patel, NRC-NRR R.B. McGehee N.S. Reynolds NRC Resident inspectors Office l