ML20112A567

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Jan 1985
ML20112A567
Person / Time
Site: Summer 
Issue date: 01/31/1985
From: Dixon O, Loignon G
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Barry L
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8503180369
Download: ML20112A567 (5)


Text

'

o Director, Of fice of Resource Management January Monthly Operating Report February 14, 1985 ATTACHMENT I AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50/395 UNIT V.

C.

SUMMER I DATE 02/14/85 COMPLETED BY G.

A.'Loignon TELEPHONE (803) 345-5209 MONTH JANUARY 1985 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1.

650 17.

313 2.

678 18.

462 3.

759 19.

855 4.

721 20.

884 5.

687 21.

887 6.

688 22.

893 7.

627 23.

892 8.

-33 24.

894 9.

43 25.

896 10.

394 26.

899 11, 864 27.

897 12.

877 28.

899 13.

138 29.

898 14.

-36 30.

899 15.

120 31.

897 16.

184 8503180369 850131 y

PDR ADOCK 05000395 r() 1 R

pop y

r I

Director, Office of Resource Management January mnthly Operating Report Page 2 February 14, 1985 ATDOIMEtfr II OPERATING DATA REPORT DOCKET NO.

50/395 UNIT V. C. SLMER I DATE 02/14/85 COMPLETED BY G. A. Icignon TELEPHONE (803) 345-5209 OPERATING STA'IUS

1. Reporting Period:

JANUARY 1985 Gross Hours in Reporting Period: 744

2. Currently Authorized Power Invel (MWt):

2775 Max. Depend. Capacity (MWe-Net):

885 Design Electrical Rating (MWe-Net):

900

3. Power Ievel to which restricted (If Any)(MWb-Net): N/A
4. Reasons for Restrictions (If Any): N/A

'IHIS MONIH YR 'IO DATE CIMJIATIVE

5. Nunber of Hours Reactor Mis Critical 689.5 689.5 6,242.9
6. Reactor Reserve Shutdown Hours 0

0 0

7. Hours Generator on Line 656.0 656.0 6,021.7
8. Unit Reserve Shutdown Hours 0

0 0

9. Gross '1hermal Ehergy Generated (MWH) 1,515,633 1,515,633 14,848,219
10. Gross Electrical Energy Generated (MNI) 500,360 500,360 4,932,509
11. Net Electrical Ehergy Generated (MHH) 473,410 473,410 4,665,506
12. Reactor Service Factor 92.7 92.7 65.5
13. Reactor Availability Factor 92.7 92.7 65.5
14. Unit Service Factor 88.2 88.2 63.2
15. Unit Availability Factor 88.2 88.2 63.2
16. Unit Capacity Factor (Using EC) 71.9 71.9 55.3
17. Unit Capacity Factor (Using Design MWe) 70.7 70.7 54.4
18. Unit Forced Outage Rate 11.8 11.8 10.9
19. Shutdowns Scheduled Over Next 6 mnths (Type, Date, and Duration of Each):

N/A

20. If Shut Down at Ehd of Report Period, Ehtimated Date of Startup:

N/A

21. Units in Test Status (Prior to Camercial Operation):

E0 RECAST ACHIEVED Initial Criticality N/A 10-22-82 Initial Electricity N/A 11-16-82 0mmercial Operation N/A 01-01-84

Director, Office of Resource Management January Monthly Operating Report P ge 3 February 14, 1985 ATTACHMENT III UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.

50/395 UNIT V.

C.

SUMMER I DATE 02/14/85 COMPLETED BY G.

A.

Loignon TELEPHONE (803) 345-5209 (1)

METHOD OF (2)

TYPE SHUTTING DOWN F: FORCED DURATION THE REACTOR OR CORRECTIVE ACTIONS /

NO.

DATE S: SCHEDULED (HOURS)

REASON REDUCING POWER COMMENTS 1

850107 F

38.9 A

1

1) Repair Turbine Generator Hydrogen Leak 2

850113 F

49.1 B

1

2) Inadvertent Resin Intrusion Into Condensate System

., - ~.

Director, Office of Resource Management January Monthly Operating Report Page 4 February 14, 1985 ATTACHMENT IV NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE The Virgil C.

Summer Nuclear Station, Unit No. 1, was operating at 75% power at the beginning of January 1985.

On January 7, 1985, at 2249 hours0.026 days <br />0.625 hours <br />0.00372 weeks <br />8.557445e-4 months <br />, the unit was shutdown for repair of a turbine generator hydrogen leak.

The outage was 38.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br /> in duration.

On January 13, 1985, at 0542 hours0.00627 days <br />0.151 hours <br />8.96164e-4 weeks <br />2.06231e-4 months <br />, the unit was shutdown because of an inadvertent resin intrusion into the secondary side of the Plant.

The Plant was restarted when chemistry limits were reestablished.

The outage was 49.1 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in duration.

On January 31, 1985, the Plant was operating at 100% power.

I r

SOUTH CAROLINA ELECTRIC & GAS COMPANY s

post arrict ve4 COLUMatA. SourH CAROLINA 29218 February 14, 1985

o.
  • o =o". >"-

VtCE PatsiDENT Nuctran OpraatioNS Director, Office of Resource Management U.S.

Nuclear Regulatory Commission MNBB 7602 Washington, DC 20555 ATTN:

Mr. Learned W.

Barry

SUBJECT:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 January Monthly Operating Report

Dear Mr. Barry:

Enclosed is the January 1985 Monthly Operating Report for the Virgil C.

Summer Nuclear Station, Unit No.

1.

This submittal is made in accordance with the requirements of Technical Specification 6.9.1.10.

If there are any questions, please call us at your convenience.

ery tru

yours,

/

O.

W.

Dixon, Jr.

CJM: GAL:OWD/ led Attachment cc:

V. C.

Summer C.

L. Ligon (NSRC)

T.

C.

Nichols, Jr./O. W.

Dixon, Jr.

K.

E. Nodland E.

H.

Crews, Jr.

R.

A.

Stough E.

C.

Roberts G.

Percival W. A.

Williams, Jr.

C.

W.

Hehl H.

R.

Denton J.

B.

Knotts, Jr.

J.

Nelson Grace INPO Records Center t

l Group Managers ANI Library l

D.

A.

Nauman L.

N.

Carter l

O.

S.

Bradham C.

S. Gramling C.

A.

Price NPCF File

.l: