ML20108D093

From kanterella
Jump to navigation Jump to search
Application for Amend to License NPF-73,consisting of Change Request 106,modifying Design Feature Section 5.3.1 to Allow Use of ZIRLO as Fuel Rod Clad Matl
ML20108D093
Person / Time
Site: Beaver Valley
Issue date: 04/29/1996
From: Jain S
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20108D094 List:
References
NUDOCS 9605070270
Download: ML20108D093 (2)


Text

.

e e

v Valley Poww Station Shippingport, PA 15077-0004 "NNN[N..w.ni April 29, 1996 raxf II II $

r l

o Division U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No. 2 Docket No. 50;412, License No. NPF-73 Proposed Operating License Change Request No.106 Pursuant to 10 CFR 50.90, Duquesne Light Coml any requests an amendment to the i

above license in the form of a Technical Specification change. The proposed change will modify Design Feature Section 5.3.1 to allow use of ZlRLO as fuel rod clad material. It is respectfully requested that the NRC staff review and approve this license amendment request no later than August 30, 1996, so that the amendment is in place prior to loading the new ZIRLO fuel rods into the reactor vessel.

The proposed Technical Specification change is presented in Attachment A. The i

safety analysis (including the no significant hazards evaluation) is presented in Attachment B.

This change has been reviewed by the Onsite Safety Committee and Offsite Review Committee. The change was determined to be safe and does not involve a significant hazard consideration as defined in 10 CFR 50.92 based on the attached safety analysis.

Sincerely, Sushil C. Jain c:

Mr. L. W. Rossbach, Sr. Resident Inspector Mr. T. T. Martin, NRC Region I Administrator Mr. D. S. Brinkman, Sr. Project Manager Mr. W. P. Dornsife, Director BRP/DEP

)'

Mr. M. P. Murphy (BRP/DEP) l DEllVERING I

9605070270 960429 0UALITY DR ADOCK 05000412 i

[g[ggy p

PDR So 42 P

AFFIDAVIT FOR APPLICATION OF AMENDMENT COMMONWEALTH OF PENNSYLVANIA)

) Ss:

COUNTY OF BEAVER

)

a

Subject:

Beaver Valley Power Station, Un' No. 2 l

BV-2 Docket No. 50-412, License ho. NPF-73 Proposed Operating License Change Request No.106 Before me, the undersigned notary public, in and for the *unty and Commonwealth aforesaid, this day personally appeared Sushil C. Jain, to me known, who being duly sworn according to law, deposes and says that he is Division Vice President, Nuclear Services of the Nuclear Power Division, Duquesne Light Company, he is duly authorized to execute and file the foregoing submittal on behalf of said Company, and the statements set forth in the submittal are true and correct to the best of his knowledge, information and belief.

g.,s.x, @

\\

Sushil C. Jain Subscribed and sworn to before me i

Y on thisjf ay of

, f??h ina L 4 ptar' Public

~

v Mauw ess

  • NA

$N