Forwards Supplemental Response to IE Bulletin 84-03, Requested in 850109 Telcon,Re Adverse Effect of Dropped Fuel Assembly on Pressray Seal.Potential for Problem Evaluated & Tests Determined That No Hardware Changes Required
ML20107M337
Person / Time
Site: Mcguire, Catawba, McGuire, 05000000
Issue date: 01/29/1985
From: Tucker H
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-84-03, IEB-84-3, NUDOCS 8503010241
Download: ML20107M337 (2)


Text

,

O s

DuxE POWER GOMPANY e.o. nox aasso CHARLOTTE, N.C. 28242 HAL B. TUCKER TELEPHONE g

.J ::- :"-

85 FEB 6 A8:03 January 29, 1985

.Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Subject:

McGuire Nuclear Station Catawba Nuclear Station Docket Nos. 50-369, -370, -413, and -414 NRC/01E Bulletin 84-03, Supplemental Response

Dear Mr. O'Reilly:

Duke provided an initial' response to IE Bulletin 84-03 in a letter dated November 21, 1984. Additional information was provided in a letter dated January 18, 1985.

On January 9, 1985, a talephone conference call was held between Duke and NRC staffs. NRC expressed concern for the adverse effect of a dropped assembly on the Pressray seal and requested that Duke evaluate this or protect the seal.

Duke has evaluated the potential for a dropped fuel assembly to damage the cavity seal and determined that no hardware changes are required. The bases for this is three fold.

First, the fuel handling mechanism is designed to prevent inadvertent release of an assembly.

It is single failure-proof and it is highly unlikely that an inadvertent release will occur. Second, the-period of time an assembly is over the cavity seal is very small. Thus, the exposure of the seal to an inadvertently released assembly is very small. The combination of these two provides an extremely low likelihood that an assembly would ever be dropped on the cavity seal. Finally, even if. an assembly were dropped on the seal, recent Duke test data shows that the seal would remain in tact.

A~ summary of the testing is provided in the attached.

There are additional considerations regarding the potential hardware modification which make it undesireable. Additional personnel radiation exposure of some magnitude would be needed to install and remove the hardware at each outage.

It would be a personnel hazard to those working in the area, and it is another heavy load that could cause damage to fuel or equipment if dropped. These considerations, in addition to the analysis described earlier form the bases of the Duke decision to make no hardware changes to the reactor vessel cavity seal design.

If_there are any questions, please advise.

Very truly yours.

WN Hal B. Tucker 8503010241 850129 PDR ADOCK 05000369 PDR HBT/mjf a

[ L

- //

Attachment i l

L s

Mr.'-James P. O'Reilly, Regional Administrator

/ January 29, 1985-Page ;

l L

cc:

Mr. R. C. DeYoung, Director

0ffice of Inspection and Enforcement l

U. S. Nuclear Regulatory Commission Washington, D. C.'20555 E

Document Control Desk.

U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. W. T. Orders NRC Resident Inspector

.McGuire Nuclear Station P. K. VanDoorn NRC Resident Inspector

Catawba Nuclear Station L

...m_

DUKE POWER COMPANY McGuire Nuclear Station Catawba Nuclear Station Supplemental Response to IE Bulletin 84-03 A series of four tests were conducted to establish the consequences of a postulated drop of a fuel assembly on the reactor vessel cavity seal.

The tests and test results are outlined below:

Assumed conditions of operation at time of accident.

1) The cavity seal is in place and inflated to 35 psi air pressure. (normal operating conditions)
2) Annulus opening is 2 1/4" wide with a differential elevation of 1/4".

(Upper bound condition taken from field survey of the area in question)

3) The seal is covered by a 24' head of water.

(normal operating conditions)

4) The fuel assembly in transient is inside the refueling mast, and raised 19 1/2" above the vessel flange.

(normal condition, fuel is not handled outside the refueling mast)

5) The fuel assembly in transient weighs 1600 lbs. (max. assembly weight in air, fuel plus control rods)
6) Fuel is drr,pped and free falls until impact with the seal.

Testing Setsp:

The testing fixture head used for the cavity seal pressure tests was used to represent the annulus opening in these tests. The head was set up with a 2 1/4" width and a 1/4" difference in relative elevation. The seal test specimens were seals no. 2 and 5 from the pressure testing tests. The fuel assembly was represented by a 1600 lb weight. The assembly end fixture, through which any impact must occur, was machined to the exact dimensions of those in service at McGuire and those that will be in service at Catawba. All loads were applied through the 13/8" x 13/8" legs on the end fixture mockup.

Tests:

Test No. 1:

Test number 1 used seal specimen number 2 in an inflated condition. Impact was through two of the four legs on the end fixture model. The drop height was 19 1/2".

The seal showed scuffing of the upper surface under each ead fixture leg.

Two small cuts approximately 1" long and 1/2" deep were made under each impact area along the seal solid rubber wedge section. The seal showed no permanent set in either the head or wedge areas. The seal remained inflated and was not displaced further in the annulus opening.

Test No. 2:

' Test number 2 was identical to test number 1 except impact area was through one leg. The seal showed only scuffing of the upper surface under the end fixture leg. The seal was not cut and did not deflate. No permanent set was imparted to the seal head or wedge. The seal was not displaced further into the annulus.

Test No. 3:

Test number 3 was identified to test number 1 except seal number 5 was used, uninflated. The impact seated the seal into the opening approximately 1".

The seal showed scuffing of the upper head under each end fixture leg and

two small cuts approximately 1" long and 1/2" deep along the seal wedge under each loading point. The seal showed no permanent set in either the head or the wedge areas. The seal did not push through the annulus opening.

Test No. 4:

Test number 4 was identical to test number 2 except seal number 5 was used in the uninflated condition..The impact seated the seal into the opening approximately 3/4".

The seal showed only scuffing of the upper surface under the impacting leg. No cutting of the seal was experienced. No permanent set was impacted to the seal head or wedge and the seal did not push through the annulus.