1901 Chouteau Avenue Post Office Box 149 St. iouis, Missouri 63166 314 554-2650 Uurou apri1 17, 199e oe >'er sca "

Etscraic t'";r,',,"cc

?'"'"""'

s U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-137 Washington, D. C. 20555-0001 Gentlemen: ULNRC-3356 CALLAWAY PLANT DOCKET NUMBER 50-483 REVISION TO TECHNICAL SPECIFICATION 3/4.3 - INSTRUMENTATION Union Electric Company herewith transmits an application for amendment to Facility Operating License Number NPF-30 for Callaway Plant. This application proposes to change Technical Specification 3/4.3,

" Instrumentation" by adding the Main Steam and Feedwater Isolation System (MSFIS) actuation logic and relays to Functional Units 4.b and 5.a of Tables 3.3-3, 3.3-4, and 4.3-2. Table 3.3-3 is further revised by the addition of Action Statements 27a and 34a, which provide guidance in the event of an inoperable MSFIS channel or train. These proposed changes are the result of a modification that will replace existing digital portions of the MSFIS with digital processor equipment.

The Callaway Plant On-Site Review Committee and the Nuclear Safety Review Board have reviewed and approved the amendment request. Attachments 1 through 5 provide the Technical Specification changes, Safety Evaluation, Significant Hazards Evaluation, and Environmental Consideration, respectively. We have concluded that there is no significant hazard consideration as determined per 10CFR50.92. Pursuant to 10CFR51.22 (b) , no environmental impact statement or environmental assessment need be prepared in connection with the issuance of this amendment.

24004$  ;

9604240090 960417 00/

PDR ADOCK 05000483 PDR su P lh j

We request approval of this amendment by i September 1, 1996, to be effective on the date of issuance and to be implemented prior to startup from Callaway Plant Refuel 8 (Fall 1996) .- If you have any ;

questions concerning the amendment application or the i exemption request, please contact us. l Very truly yours, i

Donald F. Schnell l WEK/ I I

Attachments: 1) Technical Specification Changes (marked-up)

2) Technical Specification Changes (re-typed) i
3) Safety Evaluation j
4) Significant Hazards Evaluation i
5) Environmental Consideration l I

1 1

i i

l t

l l

I l

l l . STATE OF MISSOURI )

) SS CITY OF ST. LOUIS )

l l

Donald F. Schnell, of lawful age, being first duly sworn 1 upon oath says that he is Senior Vice President-Nuclear and '

an officer of Union Electric Company; that he has read the I l foregoing document and knows the content thereof; that he has  !

executed the same for and on behalf of said company with full l power and authority to do so; and that the facts therein i stated are true and correct to the best of his knowledge, information and belief.

7 By

'Do6ald F. 'Schnell i

Senior Vice President -l Nuclear SUBSggtIBED and sworn to before me this /// DOM day of UM) /

r

, 1996. .

l l

c BARBARA PFAk NOTARY PUBLIC-STATE OF MISSOURI l MY COMMISSION EXPIRES APRIL 22,1991 I SI, LOUls COUNTX i-

cc: T. A. Baxter, Esq.

Shaw, Pittman, Potts & Trowbridge 2300 N. Street, N.W.

Washington, D.C. 20037 M. H. Fletcher Professional Nuclear Consulting, Inc.

19041 Raines Drive Derwood, MD 20855-2432 L. Joe Callan Regional Administrator U.S. Nuclear Regulatory Commission Region IV l 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011-8064 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Kristine M. Thomas (2)

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 1 White Flint, North, Mail Stop 13E16 11555 Rockville Pike Rockville, MD 20852-2738 Manager, Electric Department Missouri Public Service Commission P.O. Box 360 Jefferson City, MO 65102 Ron Kucera Department of Natural Resources P.O. Box 176 Jefferson City, MO 65102 Don Woodlan TU Electric 1601 Bryan Street Dallas, TX 75201-3411 Pat Nugent Pacific Gas & Electric Regulatory Services P.O. Box 56 Avila Beach, CA 93424 i

!