Forwards Response to NRC Re Violations Noted in Insp Rept 50-352/84-27
ML20107B590
Person / Time
Site: Limerick 
Issue date: 10/12/1984
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20107B592 List:
References
NUDOCS 8411020254
Download: ML20107B590 (1)


Text

_ _....

na-4 g

2840832950 g

PHILADELPHIA ELECTRIC COMPANY

,g y

23O1 MARKET STREET P.O. BOX 8699

'5; 1881 -1981 PHILADELPHIA PA.19101 f-(215)841-4502 JOHN S. KEMPER g

VIC E PR ESID E NT L-anc.sma a nens amo mass ancM E

^

C..

-<g Dr. Thmas E. Murley, Director E-United States Nuclear Regulatory rcnnission Office of Inspection and Enforoment, Region I g

631 Park Avenue King of Prussia, PA 19406 4

d

Subject:

USNBC IE Region Letter dated September 14, 1984 RE: Site Inspection of June 11-12, 1984 Inspection Report No. 50-352/84-27

-J Limerick Generating Station - Unit 1 File: QUAL 1-2-2 (352/84-27)

L h

= - -.

=.

Dear Dr. Murley:

In response to the subject letter regarding items identified 2

during the subject inspection of construction activities authorized by t

NBC License No. CPPR-106, we transmit herewith the following:

-l K

Attachment I - Response to Appendix A

_r?

Should you have any questions concerning these itens, we would be pleased to discuss them with you.

=gr e

Sincerely,

-j

"~

JPE/drd10118401 g

w Attachnent Copy to:

Director 'of Inspection and Enforecrnent E

United States Nuclear Regulatory Ccmnission 7

Washington, D.C.

20555 m_

S. J. Chaudhary, USNBC Resident Inspector 7

+

8411020254 841012 gDRADOCK 05000352 f

PDR y

fc 'c /

a 2840832950 g, Q 840815060 1

~.

p aEPI 3 jgg,;

~

Astm Mr. Richard W. Starostocki l~O be Director, Division of Projects and Rasident Programs, Region I

  • United States Nucicar RerJ1 story Cc=r.ission

~

631 Park Avenue Ei".; Of I';:ussit., PA 19406

Subject:

NRC Cpen Itom 84-27 goaling of Instrument conduits in High Humidity Areas Limerick Generating Station, Unit 1 Docket Nu.bor 50-352 Rcf:

Letter from J. S. Kemper to R. W. Starostecki dated August 29, 1984 I

t Files GOVT 1-1 (NRC)

Dear Mr. Etarostocki:

In the referenced letter, P.E.co. stated that it is our pregram that all niectrical devices located in areas subjected to a' harsh environ =ent of high humidity coincident with elevated pressure have their electrical conduito senled at the device.

It has recently ceme to our atte'ntion that a nurbor of condui'ts to elsetrical devices inside prir.ary centainment have not as yet been sealed. This is contrary to the requirements outlinod,in Section 4.6 of our drawing,8031-E-1406.

All electrical devices within primary containment which are required to operate either during or af ter an accident are pro-vided ylth qualified conduit seals.

All class 1E electrical devices which have not been sealed are being tracked and evaluated on Non-Confomanco Report Hur.bor 10378.

If our evaluation shows that any of these devices must be scaled to r.aintain their quali-fication, their conduits will be sealed prior to fuel load.

{

4

.E c

{} L'k". W g pv 4

op H 3

[l','..RJchsrdW..Startatecki

' TpSEQNO 2840815060 2840832950 i

sealing of the conduits ~ to the other electrical devices inside primary c:,r.tainr.cnt will be deferred to the first refueling outage as - these coala are only needed to satisfy our own requircr.ent for r.axie.1 zed reliability, sincerely,

' S' W< eh 99.og ET5/JSK:tus