D.

k PUBLIC SERVICE COMPANY OF COLORADO P.

O.80X 84O

DENVER, COLORADO 8020t Oscan n.2.zz January 28, 1985 v.ce m sioe~r Fort St. Vrain Unit No.1 P-85030 TM@20MS %

Regional Administrator j

.Iu ear Regulatory Comission

(

-AE 611 Ryan Plaza Drive, Suite 1000

\\

y Arlington, Texas 76011 Attn: Mr. Eric H. Johnson

SUBJECT:

NRC Letter from Mr. R.D. Martin to Mr. 0.R. Lee Dated 01/17/85

Dear Mr. Johnson:

The subject letter listed (in Enclosure 3) the PSC comitments that need to be accomplished prior to Fort St. Vrain startup, as well as some additional comitments made by PSC during the PSC/NRC meeting of January 15, 1985.

The letter requested that PSC contact the NRC if PSC's understanding of these comitments is different from that of the NRC.

PSC's Mr.

M.

H.

Holmes discussed these comitments on January 22, 1985 with Messrs. P. C. Wagner and R.

E.

Ireland.

A sumary of the discussion is given below:

1.

NRC Statement in Item IA: An evaluation of the CRDM failure mechanism as understood by PSC will be provided - by January 1, 1985.

PSC Clarification:

The evaluation will be provided by January 31, 1985.

I-lCOS gtpogp OR M O 8502110668 850128 PDR-ADOCK 05000267 0

bd P

pm 8 0

th P-85030 Page 2 2.

NRC Statement in Item IE:

CRDM instrumentation will be evaluated through the use of redundancy checks and position indication-checks; a report will be made by January 31, 1985.

PSC Clarification: The report due on January 31, 1985 will describe the program for evaluating the CRD instrumentation; no results will be reported by that date.

3.

NRC Statement in Item IF: All CRD0As will have temperature monitoring capabilities installed which will be continuously monitored.

It is intended that continuous recording capability for a representative number of CRD0As will be available prior to restart.-

PSC Clarification: PSC understands the phrase " continuously monitored" to mean monitored and alarmed.

There is no intent to have someone at the readout panels continuously to observe temperatures.. While it is PSC's intent to use our best efforts to install ~ continuous recording capability for representative CRD0As prior to startup, this is not a commitment since-the recorders may not be received-in time.

4.

NRC Statement in Item VB: The proposed surveillance program will be implemented,- to the extent practical, prior to restart.

PSC Clarification:

PSC proposes to submit an interim surveillance program by January 31, 1985 describing what is deemed practical to do and implement prior to restart.

5.

NRC Statement in Item VI A:

A report describing modifications to and evaluations of CRDM instrumentation to be completed prior to restart will be submitted by January 31, 1985. The report will also discuss long-term actions and proposed schedules.

PSC Clarification:

PSC will not know by January 31, 1985 its long term actions and proposed schedules, but will provide such information to the extent available.

4 e

~

n

- 2.l

. P-85030 Page -3 6.

NRC. Statement'in Item VI B: ;- A. report clarifying the phased implementation of the QA -procedural changes will be submitted by January 31, 1985.-

PSC Clarification:

The report to be-: submitted by January 31, 1985_will-describe PSC's overall plan,- schedule e

j and status 'for QA review of safety-related procedures and Technical Specification surveillance procedures.

}

.Very' ruly yours, dh M

0. R.-Lee, Vice President Electric Production ORL/SLG:pa 1

1 I

i i

4 t-i

}.

t 1-

'~

i i

-v-

,?,, _,,,,

'