ML20105C352

From kanterella
Jump to navigation Jump to search
Forwards Addl Info Re NRC Insp of Results of Previous Leak Rate Tests in Which 33 Apparent Irregularities & 25 Missing Calculations Identified.Info Eliminates Many NRC Questions
ML20105C352
Person / Time
Site: Crane 
Issue date: 08/18/1983
From: Thorpe J
GENERAL PUBLIC UTILITIES CORP.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
5211-83-241, NUDOCS 8311020294
Download: ML20105C352 (7)


Text

-

, l*.

GPU Nuclear Corporation a

s ppa y, ew Je sey07054 201 263-6500 TELEX 136-482 Writer's Direct Dial Number:

August 18, 1983 5211-83-241 Mr. Richard W. Staroste'ki, Director Division of Resident 1 oject Inspection U.S. Nuclear Regulatory Comnission, Region I 631 Park Avenue King of Prussia, Pa. 19406

Dear Mr. Starostecki:

As part of his recent inspection of the results of previous leak rate tests at 7MI-1, Dr. Gung of your staff identified 33 apparent irregularities and 25 missing calculations and provided this information to Henry Shipnan on August 9,1983.

We have conducted a review of our files and of supportirv3 data and believe that we have discovered information that eliminates many of the questions raised by Dr. Chung.

with the additional information:The following table compares the information available 2_6_ Missing Calcul_ations 11 were discovered misfiled with other test data 6 were logged at different times than the test was run.

1 has no record in the log that corresponds to the NBC date/ time 8 calculation sheets are still missing 12 Apparent _ Hydrogen Mditions During Test PeriM

- 8 incorrect chart time references

- 1 addition made prior to test period 3 indications of additions made during test period estI@2.c61pM GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation h

21 Apparent Water Additions During Test Period 11 irrorrect chart time reference

- 7 normal level variations which generally correspond to pressurizer level changes 1 addition was made and recorded on calculation'sM et, in accordance with procedures 2 additions were made durire test and not accounted for in

=

calculation Calculations were performed takirs into account the.three cases of hydrogen addition during the test period and the two water additions., In all cases, the calculated leak rate was significantly below the allowable limit.

Enclosures 1, 2 and 3 to this letter specify the disposition of each item on Dr. Chung's list by date and time.

We had hoped to meet with you to discass this additional data.

However, at your request we are subnitting the data in this letter to assist you in expediting the preparation of the report of this inspection. If further discussion is necessary to clarify this additional data, we would be glad to meet with you at your convenience.

If such a meeting is appropriate, please contact John R. Thorpe, Director-Licensing and Regulatory Affairs, at 201-299-2272.

Very truly yours, WC J. R. 'Ihorpe Director Licensing & Regulatory Affairs

=

=

M lii 5

m

7 m-

"*...] #l, W

's w

,[._

~

s ia SNCLO3dRE Lt

+

- DISPOSifLON 02-LEAK RAfd fESf?1303-1. L MISSING DAIA Sd8dfS

-- a CR0 LOG LOGGED' DAf3 fDid LEAK RAIZ' DISP 03IrION

'4-29-18 L400 2 0.0991

[ Data n,heet fo'itnd '

correspondence to 0820 calculation.'

~

5-7-78 1621'

-0.263L Data sheet found -~misflied. 21 1025

.-0.846 Missing'

+

5-29-18 1945 0.4877 Data sheet-foun'd misfLied 6-3-78~

-0845~

-0.0704'

-Data sheet found - misfLLed.

6-5-78 2204

+0.1

-Data sheet found mLsflied.

1 6-6-18 0530

+0.5812 Data sheet found -Corresponds to 6/5/78 2354 calculatLon.

'7-4-78 2245

+0.9967 MLssing 1-10-78 0338

-0.0711 Missing j

8-3-78 0930

+0.11 Data sheet found misf LLed.

8-4-78

-1830

+0.4467 Data sheet found misfLled.

8-19-78 1450

-0.238

. Missing 8-26-78.

1530

-0.1352 Data shnet found - mLsfiled.

9-3-78 1138

+0.9667 Missing 9-3 1247

+0.2961 Data sheet found - misfiled.

4.

9-26-78 0343

-0.4074

-Data shaet found misfLied.

11-5-78 1950

+0.3395 data sheat found -

corresponds to 1802 calculatlon.

(

N~

-J o,( < *;

f pl'

t.

'2 -

DISP 03IfION OF LSA4 2AfE fE3 f' 1303-1. L MIS 3ING DATA 'StIZEfS 4

CR0 IDG LJ0080-.

iDAfB-TIMd LEA 4 RAf8:

-DISPOSITION 4

, 10-78 1125 1-0.53741 Data. sheet found -corresponds to 1033 calculat Lon. -

.12-11-78

-0432-

' -0.811a'

.Misstag-1-7-79 0600

'Nollog entcy found at:.this time Data ' for 0415, L200,-

and 1830 calculations' available.

1-18-79 0530

-0.69 Data sheet found -coccesponds

-r.o 0401 calculatLon.

1-18-79.

1310 SAf unable to veelfy but probably.

correr. ponds'to 0959 calculation (.0499 gpa).

. 26-19 0032

-0.4909 Missing 1-26-79 LLO6

+0.2788 Data sheet found misflied.

1-29-79 03LO

-0.3124 MLsaing 2-6-79 0836

-0.1827 Data sheet found - misflied.'

4 r /g i - - e

.....i_...

g

-=

.~.-- - -

~c

. -:l i.+

.. ~ '

_.p c.

SNCLOSUR3.2 DISPOSifION OF.

-WAf8R ADDICI0d3 00 RING'LSAI RAfE TESTS DAf8

. TIM 8 DISPOSITIONI Start End.

1.

5/12/18 E0047

-0147 Variable Mdf Level-Some cort aspondence to pressurtzer le~ vel.

Chart signature not t/pical of additLon.

2.

5/12/78 L1643 1743-

.Additton Logged'at-1745 may have affected test.

Not accounted. for in calculation.

3.

5/15/78 1736 1836 Chart tLma reference in error.

4.

6/4/18 0756 0856 Chart time reference in error.

5.

6/11/73 0804 0704 Variable MUT Level-Some correspondence:to pressurizer level.

Chart' signature not typtcal of.addLtton.

6.

6/21/73 0341 0441 Chart time reference in error.

7 7/6/78 1648 1748 Chart time reference in error.

8.. 8/22/18 0838 0938 Chart time reference in error.

9.

8/29/18 1547 1647 Chart time reference Ln error.

10.

d/31/78 0801 0901 Chart time reference la error.-

11, 9/1/78 1825 1925 Variable M0r level - Some correspondence to pressurtzer lever 1.

Chart signature not typtcal of addLtton.

12.

9/18/78 2036 2136 Chart time reference in error.

13, 9/22/78 2100 2200 Chart time ~ reference in error.

14.

10/17/78 -1201 1301 Variable MUr level-Some correspondence to pressurizer level.

Chart signature not typtcal of addLtton.

15.- 10/29/73 1544 1644

, Chart time reference la error,

.x i

5 2

a i

ENCLO30iM 2 f

i 9 i

-DISP 03IIION OF WAfSP. ADDIfl0N3 DURING LEA 4 RArd fdS f3 4

DATE

- f fAZ DIS PJ3ITION 2

Start End 4

$=

re 3

16.

11/7/78 1608 1703 Variable MUr Level - Some correspondence to i

pressurtzer level.

Chart signature not

]

typtcal of addition.

17, 11/21/7d 0206 0306 Variable MUf Level - So:ne correspondence to i

pressurizer level.

Chart signature not 1

typical of addtt.Lon.

=

18, 11/28/78 1653 1853 Variable MJf Level - Some correspondence to 5

pressurtzer level.

Chart signatura not typteal of addLtton.

  • 19.

12/13/78 1842 1942 Addition made during test and logged La CR0 l

log but not in calculation.

j 20.

1/6/19 0756 1156 Addition accounted for in calculation.

21.

1/19/79 0841 0941 Chart time reference in error.

a v' 8<

N0fE: Chart time error was determined by compering levels used Ln calculatLon ET I

to those on chart during perLod of test. An error was noted when Lt was clear j

the level change could not have taken place during test period.

-.:o$;

$[i[h g

s l

g.

l'

=

f.:.(}(

f

s..,,- F4 D

e.'~ b,5

...,..j

.
.4
l ["R 4

.p.?.:

K w.3 I

b

g w

v

_, +

. ;..J ?;,**,y j

~

~

ENCLOSUR3L3:

~

DISP 03ICIO3 0l

'HfDROGEN ADDIIION3 00 RING LSAK RAIS f8STS 2

'DATS fIMd 01SPOSIf10N-Start-Snd 4

1.' 5/9/78

-0738

'0838' Chart:ttme reference error.

2.

8/8/78 073': '0835 Addition may haia been made:durlag test:

5

' p e r io d.-

3.

9/8/18 1629

.1729' Chart - time reference error.

!4.

9/17/78 0503-0608' ~

Level Increase' occurred prior to test.

5.

9/18/78 2355. 0055

-Chart ttme reference error.

6 9/19/78 2348 0048-Chart time reference erroe.

7.

10/20/18-1646-1746 AddLtton made during test-perlod.

8.

11/12/73 --0816 0916.

AddLtton made durind test'peelod.

9.

. L2/9/78' 2353 0053 Chart time reference error.

10, 12/18/78 0830 0930 Chart time reference error.

Lt.

2/2/19 1600 1700 Chart time reference error.

L2, 2/3/79 1616 1716 Chart tLae reference error.

NOTE: Chart time error was determined by comparing levels used in calculation to those on chart during period of test. ~ An error was noted when Lt was clear the level change could not have taken placa during test perLod.

i-l l