ML20104B540

From kanterella
Jump to navigation Jump to search
Corrected Table 3, TIP Signal Symmetry Results, to Cycle 5 Startup Test Rept
ML20104B540
Person / Time
Site: LaSalle 
Issue date: 09/08/1992
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20104B534 List:
References
NUDOCS 9209150379
Download: ML20104B540 (1)


Text

-

TABLE 3 T I I' SIGliAL S Ytt4ETRY FESULTS All numbers shown are averages from two OD-1 data sets (from 5-4-92 and 5-5-92 at 99.7% and 99.5% power, respectively).

Symmetrical TIP Pair Absolute Percent Ru:1 era (Cere Lo.catient Difference TIP Pair a

_t of ?ASE1 Deviatign*

1 (16-09) 6 (08-17) 3.07 4.09 2 (24-09) 13 (08-25) 0.56 0.63 3 (32-09) 20 (08-33) 0.26 0.29 4 (40-09) 27 (08-41) 2.00 3.47 5 (48-09) 34 (08-49) 6.78 14.32 s

8 (24-17) 14 (16-25) 0.26 0.27 9 (32-17) 21 (16-33) 1,66 1.61 10 (40-17) 28 (16-41) 1.24 1.25 11 (48-17) 35 (16-49) 3.74 4.18 12 (56-17) 40 (16-57) 0.87 1.95 16 (32-25) 22 (24-33) 1.89 1.82 17 (40-25) 29 (24-41) 5.61 5.93 18 (48-25) 36 (24-49) 1.22 1.29 19 (56-25) 41 (24-57) 2.65 4.09 24 (40-33) 30 (32-41) 0.91 0.97 25 (48-33) 37 (32-49) 1.82 1.84 26 (56-33) 42 (32-57) 4.74 7.29 32 (40-41) 38 (40-49) 0.09 0.10 33 (56-41) 43 (40-57) 2.83 5.10 f - where : Absolute Difference of DASE = DASE - BAfE g

d and M =

BASE (K) g 1Asra_._2istt_3)

- - waere : i Deviation - /

100

0. 5 (BAS Ej + BASE, 9209150379 920908

{DR ADOCK 05000374 PDR

.