Text

1 Dm8 Colt industries Fairbanks Morsa Engine Division F

701 Lawton Avenue Beloit. Wisconsin 53511 608/364-4411 January 28, 1985 Office of Inspection & Enforcement U.-S. Nuclear Regulatory Commission i

799 Roosevelt Road 1

Glen Ellyn, Ill. 60137 Attention: Mr. James G. Keppler, Director, Region III

Subject:

Colt Industries-Fairbanks Morse Engine Division Emergency Diesel Generators Possible Thermostatic Valve Malfunction Fail, Safe To " Full Ccoling Position" Part-21 Report Supplemental Report ho;.8 Northeast-Utilities - Millstone III

References:

May 25,1982; June 28,1982 and September 17, 1982 Part 21 Reports - Robertshaw Valves - same subject Gentlemen:

The lower overrun assemblies in the Robertshaw valves installed on the Diesel Generator Sets at Northeast Utilities - Millstone III have been replaced with overrun assemblies utilizing cotter pins to positively lock the nut to the stem.

The units are now free of the reported potential defect.

J A copy of this report is being forwarded to the utility involved.

y" Very truly yours, nyp p

. M. Moriart MANAGER UTIL ALES JMM:jc cc: Stone & Webster Engineering Corp.

.P. O. Box 2325 Boston,-Mass. 02107 Attention: Lead Electrical Engineer J.0. No. 12179 (Millstone III)

U. S. Nuclear Regulatory Commission c/o Document Management Branch Washington, D.C.

20555

Robertshaw Controls Company' P. 0.. Box 400 Knoxville,'TN 137901 Attention
T.1T. Howell, Quality Mgr.

N

'l0 a

one.can,oon on nco.

g20s0 7sg g S-PDR L

JM 3 01985