Submits Rept of SG Tube Plugging Completed During Recent Inservice Insp.Based on Eddy Current Exam results,11 Tubes Plugged in SG 11 & 7 Tubes Plugged in SG 12.Tube in SG 12 Erroneously Plugged on Cold Leg Side (Ref LER 317/88-03)
ML20101T851
Person / Time
Site: Calvert Cliffs 
Issue date: 07/17/1992
From: Creel G
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9207220074
Download: ML20101T851 (1)


Text

. _ _ - _ _ _ _ - _ _ _ _ _ _ _ _

i A

/

,H ALTIM ORC GAS AND ELECTRIC 1650 CALVERT CUFTS PARKWAY + LUSBY, MARYLAND 20657. A702 oconoc c. cace' July 17,1992 VsCE PmtsetNT NucLEAm Lostmov (eso) #40-e4tt U.S Nuclear Regulatory Commision Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50 317 & 50-318 Report of Steittp Generator Tube Pluccine

REFERENCE:

(a)

Calvert Cliffs Unit 1 Technical Specification 4.4.5.5 Gentlemen:

As required by Reference (a), this letter reports the number of tubes plugged in the Calvert Cliffs Unit 1 Steam Generators dunng the recently completed Inservice Inspection.

Based on recent Eddy Current Examination results of the Unit 1 Steam Generators, we pluggei 11 tubes in Steam Generator No.11 and 7 tubes in Steam Generator No.12. In addition, a tube (R 93,1 67) in Steam Generator No.12, which had been erroneously plugged on the cold leg side in 1986 (LER 317/88-03), was plugged on the hot lep side. The total number of tubes plugged in Steam Generator Nos.11 and 12 are 118 and 77, respectively.

Should you have any further qur tions regarding this matter, we will be pleased to discuss them with you.

Very truly yours,

)

n

((' y,!'

,0 l

OCC/DWM/dwm/bjd cc:

D. A. Brune, Esquire J. E. Silberg, Esquire R. A. Capra, NRC D. G. Mcdonald, Jr., NRC

,)g gh

'[/[v0T4 ( (8g T. T. Martin, NRC P. R. Wilson, NRC R. I. McLean, DNR J. H. Walter, PSC.

Fj

$l I

9207220074 920717 PDR ADOCK 05000317 Ip P

PDR

_ _, _ _